메뉴 건너뛰기




Volumn 18, Issue 3, 2003, Pages 389-395

Single-shot spiral image acquisition with embedded Z-shimming for susceptibility signal recovery

Author keywords

fMRI; Single shot; Spiral imaging; Susceptibility; Z shimming

Indexed keywords

ARTICLE; AUDITORY CANAL; BRAIN; GEOMETRY; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGING SYSTEM; MAGNETIC FIELD; MATHEMATICAL ANALYSIS; MOUTH CAVITY; NEURORADIOLOGY; NORMAL HUMAN; NOSE CAVITY; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL;

EID: 0042328148     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.10355     Document Type: Article
Times cited : (38)

References (16)
  • 1
    • 0027263961 scopus 로고
    • Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging
    • Ogawa S, Menon RS, Tank DW, et al. Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. Biophys J 1993;64:803-812.
    • (1993) Biophys J , vol.64 , pp. 803-812
    • Ogawa, S.1    Menon, R.S.2    Tank, D.W.3
  • 2
    • 0028387214 scopus 로고
    • Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: A comparative study at 1.5 T
    • Bandettini PA, Wong EC, Jesmanowicz A, et al. Spin-echo and gradient-echo EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T, NMR Biomed. 1994;7:12-20.
    • (1994) NMR Biomed , vol.7 , pp. 12-20
    • Bandettini, P.A.1    Wong, E.C.2    Jesmanowicz, A.3
  • 3
    • 0023801255 scopus 로고
    • The benefits of increasing spatial resolution as a means of reducing artifacts due to field inhomogeneities
    • Young IR, Cox IJ, Bryant DJ, et al. The benefits of increasing spatial resolution as a means of reducing artifacts due to field inhomogeneities. J Magn Reson Imaging 1988;6:585-590.
    • (1988) J Magn Reson Imaging , vol.6 , pp. 585-590
    • Young, I.R.1    Cox, I.J.2    Bryant, D.J.3
  • 4
    • 0026500406 scopus 로고
    • Reduction of susceptibility artifact in gradient-echo imaging
    • Cho ZH, Ro YM. Reduction of susceptibility artifact in gradient-echo imaging. Magn Reson Med 1992;23:193-196.
    • (1992) Magn Reson Med , vol.23 , pp. 193-196
    • Cho, Z.H.1    Ro, Y.M.2
  • 5
    • 0003321956 scopus 로고    scopus 로고
    • Reduction of susceptibility effects in BOLD fMRI using tailored RF pulses
    • Sydney, Australia
    • Glover GH, Lai S. Reduction of susceptibility effects in BOLD fMRI using tailored RF pulses. In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, Australia, 1998, p 298.
    • (1998) Proceedings of the 6th Annual Meeting of ISMRM , pp. 298
    • Glover, G.H.1    Lai, S.2
  • 6
    • 0023937754 scopus 로고
    • Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation
    • Frahm J, Merboldt KD, Hanicke W. Direct FLASH MR imaging of magnetic field inhomogeneities by gradient compensation. Magn Reson Med 1988;6:474-480.
    • (1988) Magn Reson Med , vol.6 , pp. 474-480
    • Frahm, J.1    Merboldt, K.D.2    Hanicke, W.3
  • 7
    • 0032768601 scopus 로고    scopus 로고
    • Composite image formation in z-shimmed functional MR imaging
    • Constable RT, Spence DD. Composite image formation in z-shimmed functional MR imaging. Magn Reson Med 1999;42:110-117.
    • (1999) Magn Reson Med , vol.42 , pp. 110-117
    • Constable, R.T.1    Spence, D.D.2
  • 8
    • 0031029807 scopus 로고    scopus 로고
    • Multi-gradient echo with susceptibility compensation (MGESIC): Demonstration of fMRI in the olfactory cortex at 3T
    • Yang QX, Dardzinski BJ, Li S, et al. Multi-gradient echo with susceptibility compensation (MGESIC): demonstration of fMRI in the olfactory cortex at 3T. Magn Reson Med 1997;37:331-335.
    • (1997) Magn Reson Med , vol.37 , pp. 331-335
    • Yang, Q.X.1    Dardzinski, B.J.2    Li, S.3
  • 9
    • 0000548389 scopus 로고    scopus 로고
    • Gradient compensation method for the reduction of susceptibility artifacts for spiral fMRI data acquisition
    • Philadelphia
    • Stenger VA, Boada FE, Noll DC. Gradient compensation method for the reduction of susceptibility artifacts for spiral fMRI data acquisition. In: Proceedings of the 7th Annual Meeting of ISMRM, Philadelphia, 1999, p 538.
    • (1999) Proceedings of the 7th Annual Meeting of ISMRM , pp. 538
    • Stenger, V.A.1    Boada, F.E.2    Noll, D.C.3
  • 10
    • 0032851488 scopus 로고    scopus 로고
    • Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique
    • Chen NK, Wyrwicz AM. Removal of intravoxel dephasing artifact in gradient-echo images using a field-map based RF refocusing technique. Magn Reson Med 1999;42:807-812.
    • (1999) Magn Reson Med , vol.42 , pp. 807-812
    • Chen, N.K.1    Wyrwicz, A.M.2
  • 11
    • 0034894659 scopus 로고    scopus 로고
    • Single-shot EPI with signal recovery from the susceptibility-induced losses
    • Song AW. Single-shot EPI with signal recovery from the susceptibility-induced losses. Magn Reson Med 2001;46:407-441.
    • (2001) Magn Reson Med , vol.46 , pp. 407-441
    • Song, A.W.1
  • 12
    • 0036432616 scopus 로고    scopus 로고
    • Single-shot interleaved z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T
    • Gu H, Feng H, Zhan W, et al. Single-shot interleaved z-shim EPI with optimized compensation for signal losses due to susceptibility-induced field inhomogeneity at 3 T. Neuroimage 2002;17:1358-1364.
    • (2002) Neuroimage , vol.17 , pp. 1358-1364
    • Gu, H.1    Feng, H.2    Zhan, W.3
  • 13
  • 15
    • 0034839919 scopus 로고    scopus 로고
    • Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
    • Glover GH, Law CS. Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts. Magn Reson Med 2001;46: 515-522.
    • (2001) Magn Reson Med , vol.46 , pp. 515-522
    • Glover, G.H.1    Law, C.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.