-
3
-
-
0026782890
-
Comparison of alumina-polyethylene and metal-polyethylene in clinical trials
-
Zichner L.P.Willert H.-G.Comparison of alumina-polyethylene and metal-polyethylene in clinical trials Clin. Orthop. 282 1992 86
-
(1992)
Clin. Orthop.
, vol.282
, pp. 86
-
-
Zichner, L.P.1
Willert, H.-G.2
-
4
-
-
0006574723
-
The wear properties of polyethylene acetabular cups with respect various femoral components in vivo
-
H.G. Willert, G.H. Buchhorn, P. Eyerer (Eds.) Hogrefe and Huber, Gottingen
-
G. Langer, S. Blumentritt, J. Babisch, The wear properties of polyethylene acetabular cups with respect various femoral components in vivo, in: H.G. Willert, G.H. Buchhorn, P. Eyerer (Eds.), Ultra-high Molecular Weight Polyethylene as Biomaterial in Orthopaedic Surgery, Hogrefe and Huber, Gottingen, 1991, p. 154.
-
(1991)
Ultra-high Molecular Weight Polyethylene As Biomaterial in Orthopaedic Surgery
, pp. 154
-
-
Langer, G.1
Blumentritt, S.2
Babisch, J.3
-
5
-
-
0029489676
-
A comparative study of the performance of metallic and ceramic femoral head components in total replacement hip joints
-
Dowson D.A comparative study of the performance of metallic and ceramic femoral head components in total replacement hip joints Wear 190 1995 171
-
(1995)
Wear
, vol.190
, pp. 171
-
-
Dowson, D.1
-
6
-
-
0031686498
-
Effect of femoral head surface roughness on the wear of ultra-high molecular weight polyethylene acetabular cups
-
Wang A.Polineni V.K.Stark C.Dumbleton J.H.Effect of femoral head surface roughness on the wear of ultra-high molecular weight polyethylene acetabular cups J. Arthroplasty 136 1998 615
-
(1998)
J. Arthroplasty
, vol.13
, Issue.6
, pp. 615
-
-
Wang, A.1
Polineni, V.K.2
Stark, C.3
Dumbleton, J.H.4
-
8
-
-
0031594091
-
Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements
-
A. Wang, A. Essner, V.K. Polyethylene, C. Stark, J.H. Dumbleton, Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacements, Tribol. Int. 31 (1-3) (1998) 17.
-
(1998)
Tribol. Int.
, vol.31
, Issue.1-3
, pp. 17
-
-
Wang, A.1
Essner, A.2
Polyethylene, V.K.3
Stark, C.4
Dumbleton, J.H.5
-
9
-
-
0032804049
-
Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls
-
H.A. McKellop, F. Shen, W. DiMaio, J.G. Lancaster, Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls, Clin. Orthopaed. Relat. Res. 369 (1999) 73.
-
(1999)
Clin. Orthopaed. Relat. Res.
, vol.369
, pp. 73
-
-
McKellop, H.A.1
Shen, F.2
DiMaio, W.3
Lancaster, J.G.4
-
10
-
-
0035280295
-
A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding
-
A. Wang, A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding, Wear 248 (2001) 38.
-
(2001)
Wear
, vol.248
, pp. 38
-
-
Wang, A.1
-
13
-
-
0035892402
-
Effect of counterface roughness on the wear of conventional and crosslinked UHMWPE studied with a multi-directional motion pin-on-disk device
-
Saikko V.Calonius O.Keranen J.Effect of counterface roughness on the wear of conventional and crosslinked UHMWPE studied with a multi-directional motion pin-on-disk device J. Biomed. Mater. Res. 57 2001 506
-
(2001)
J. Biomed. Mater. Res.
, vol.57
, pp. 506
-
-
Saikko, V.1
Calonius, O.2
Keranen, J.3
-
15
-
-
0036023527
-
A literature review of the association between wear rate and osteolysis in total hip arthroplasty
-
Dumbleton J.H.Manley M.Edidin A.A literature review of the association between wear rate and osteolysis in total hip arthroplasty J. Arthroplasty 175 2002 649
-
(2002)
J. Arthroplasty
, vol.175
, pp. 649
-
-
Dumbleton, J.H.1
Manley, M.2
Edidin, A.3
-
16
-
-
0006544376
-
Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene
-
Wang A.Sun D.C.Yau S.S.Stark C.Dumbleton J.H.Orientation softening in the deformation and wear of ultra-high molecular weight polyethylene Wear 203/204 1997 230
-
(1997)
Wear
, vol.203
, Issue.204
, pp. 230
-
-
Wang, A.1
Sun, D.C.2
Yau, S.S.3
Stark, C.4
Dumbleton, J.H.5
-
17
-
-
0002262917
-
Impact of lubricant protein concentration on the outcome of hip joint simulator wear testing
-
A. Wang, V.K. Polineni, C. Stark, J.H. Dumbleton, Impact of lubricant protein concentration on the outcome of hip joint simulator wear testing, Trans. Orthopaed. Res. Soc. (1999) 52.
-
(1999)
Trans. Orthopaed. Res. Soc.
, pp. 52
-
-
Wang, A.1
Polineni, V.K.2
Stark, C.3
Dumbleton, J.H.4
-
18
-
-
2142827263
-
Three-body wear of UHMWPE acetabular cups by PMMA particles against CoCr, alumina and zirconia heads in a hip joint simulator
-
Wang A.Essner A.Three-body wear of UHMWPE acetabular cups by PMMA particles against CoCr, alumina and zirconia heads in a hip joint simulator Wear 250 2001 212-216
-
(2001)
Wear
, vol.250
, pp. 212-216
-
-
Wang, A.1
Essner, A.2
-
19
-
-
0032922181
-
Low-friction arthroplasty of the hip using alumina ceramic and crosslinked polyethylene-a ten-year follow-up report
-
Wroblewski B.M.Siney P.D.Fleming P.A.Low-friction arthroplasty of the hip using alumina ceramic and crosslinked polyethylene-a ten-year follow-up report J. Bone Joint Surg. B 811 1999 54
-
(1999)
J. Bone Joint Surg. B
, vol.81
, Issue.1
, pp. 54
-
-
Wroblewski, B.M.1
Siney, P.D.2
Fleming, P.A.3
|