메뉴 건너뛰기




Volumn 5, Issue 1, 2003, Pages 17-19

Five-year prospective study of immediate/early loading of fixed prostheses in completely edentulous jaws with a bone quality-based implant system

Author keywords

Clinical study; Dental implant; Early load; Immediate load

Indexed keywords

ARTICLE; BIOMECHANICS; BONE; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DENTAL SURGERY; EDENTULOUSNESS; FOLLOW UP; HEIGHT; HUMAN; IMPLANT; OSTEOLYSIS; PHYSIOLOGY; POSTOPERATIVE PERIOD; SCIENCE; SURGICAL TECHNIQUE; SURVIVAL; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TREATMENT OUTCOME; BONE DENSITY; BONE REGENERATION; DENTAL CARE; DENTURE; METHODOLOGY; MULTICENTER STUDY; PROSPECTIVE STUDY; RADIOGRAPHY;

EID: 0042011620     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2003.tb00178.x     Document Type: Article
Times cited : (69)

References (45)
  • 1
    • 0017564248 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
    • Brånemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 1977; 16(2 Suppl):1-132.
    • (1977) Scand J Plast Reconstr Surg , vol.16 , Issue.2 SUPPL. , pp. 1-132
    • Brånemark, P.I.1    Hansson, B.O.2    Adell, R.3
  • 2
    • 0019663098 scopus 로고
    • A 15 year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R. Lekholm U, Rockler B, et al. A 15 year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3
  • 3
    • 0025493944 scopus 로고
    • The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism; a prospective multicenter study of 558 fixtures
    • Van Steenberghe D, Lekholm N, Bolender C, et al. The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism; a prospective multicenter study of 558 fixtures. Int J Oral Maxillofac Implants 1990; 5:272-281.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 272-281
    • Van Steenberghe, D.1    Lekholm, N.2    Bolender, C.3
  • 4
    • 0011904968 scopus 로고
    • Histologic and histomorphometric evaluation of submerged and nonsubmerged titanium implants
    • Laney WR, Tolman DE, eds. Chicago: Quintessence
    • Gotfredsen K, Hjorting-Hansen E. Histologic and histomorphometric evaluation of submerged and nonsubmerged titanium implants. In: Laney WR, Tolman DE, eds. Oral, orthopedic and maxillofacial reconstruction. Chicago: Quintessence, 1990:31-40.
    • (1990) Oral, Orthopedic and Maxillofacial Reconstruction , pp. 31-40
    • Gotfredsen, K.1    Hjorting-Hansen, E.2
  • 5
    • 0020825709 scopus 로고
    • Hohlzylinderimplantat: Typ-F zur prothesen-retention in zahnlosen kafer
    • Schroeder A, Mawglen B, Sutter F. Hohlzylinderimplantat: Typ-F zur Prothesen-retention in zahnlosen Kafer. Schweiz Monatsschr Zahnherlkunde 1983; 93:720-733.
    • (1983) Schweiz Monatsschr Zahnherlkunde , vol.93 , pp. 720-733
    • Schroeder, A.1    Mawglen, B.2    Sutter, F.3
  • 6
    • 0026298489 scopus 로고
    • Tissue integration of one stage ITI implants: 3 Year results of a longitudinal study with hollow cylinder and hollow screw implants
    • Buser D, Weber HP, Bragge U, et al. Tissue integration of one stage ITI implants: 3 year results of a longitudinal study with hollow cylinder and hollow screw implants. Int J Oral Maxillofac Implants 1991; 6:405-412.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 405-412
    • Buser, D.1    Weber, H.P.2    Bragge, U.3
  • 7
    • 0042961804 scopus 로고
    • Experimental work on a method for the replacement of missing teeth by direct implantation of a metal support into the alveolus
    • Strock AE, Strock M. Experimental work on a method for the replacement of missing teeth by direct implantation of a metal support into the alveolus. Am J Orthod Oral Surg 1939; 25:467.
    • (1939) Am J Orthod Oral Surg , vol.25 , pp. 467
    • Strock, A.E.1    Strock, M.2
  • 8
    • 0014257582 scopus 로고
    • The blade-vent - A new dimension in endosseous implants
    • Linkow LI. The blade-vent - a new dimension in endosseous implants. Dent Concepts 1968; 11:3-14.
    • (1968) Dent Concepts , vol.11 , pp. 3-14
    • Linkow, L.I.1
  • 9
    • 0017455196 scopus 로고
    • A statistical evaluation of 952 endosteal implants in humans
    • Cranin AN, Rookin MF, Garfinkel L. A statistical evaluation of 952 endosteal implants in humans. J Am Dent Assoc 1977; 94:315-319.
    • (1977) J Am Dent Assoc , vol.94 , pp. 315-319
    • Cranin, A.N.1    Rookin, M.F.2    Garfinkel, L.3
  • 10
    • 0017275559 scopus 로고
    • The use of blade implants in a selected population of partially edentulous adults: A five-year report
    • Smithloff M, Fritz ME. The use of blade implants in a selected population of partially edentulous adults: a five-year report. J Periodontol 1976; 47:19-24.
    • (1976) J Periodontol , vol.47 , pp. 19-24
    • Smithloff, M.1    Fritz, M.E.2
  • 11
    • 0041960121 scopus 로고
    • Veterans Administration co-operative dental implant study comparison between fixed partial dentures supported by Blade-Vent implants and partial dentures
    • Kapur KK. Veterans Administration co-operative dental implant study comparison between fixed partial dentures supported by Blade-Vent implants and partial dentures. J Prosthet Dent 1987; 59:499-512.
    • (1987) J Prosthet Dent , vol.59 , pp. 499-512
    • Kapur, K.K.1
  • 12
    • 0026834154 scopus 로고
    • Retrieval analysis of a blade implant after 231 months of clinical function
    • Linkow LI, Donath K, Lemons JE. Retrieval analysis of a blade implant after 231 months of clinical function. Implant Dent 1992; 1:37-43.
    • (1992) Implant Dent , vol.1 , pp. 37-43
    • Linkow, L.I.1    Donath, K.2    Lemons, J.E.3
  • 13
    • 0022467575 scopus 로고
    • Titanium plasma spray (TPS) screw implants for the reconstruction of the edentulous mandible
    • Babbush CA, Kent JN, Misiek DJ. Titanium plasma spray (TPS) screw implants for the reconstruction of the edentulous mandible. J Oral Maxillofac Surg 1986; 44:274-282.
    • (1986) J Oral Maxillofac Surg , vol.44 , pp. 274-282
    • Babbush, C.A.1    Kent, J.N.2    Misiek, D.J.3
  • 14
    • 0024081613 scopus 로고
    • The new concept of ITI hollow cylinder and hollow-screw implants. Part 2. Clinical aspects, indications, and early clinical results
    • Buser D, Schroeder A, Sutter F, Lang NP. The new concept of ITI hollow cylinder and hollow-screw implants. Part 2. Clinical aspects, indications, and early clinical results. Int J Oral Maxillofac Implants 1988; 3:173-181.
    • (1988) Int J Oral Maxillofac Implants , vol.3 , pp. 173-181
    • Buser, D.1    Schroeder, A.2    Sutter, F.3    Lang, N.P.4
  • 15
    • 0025618219 scopus 로고
    • Immediate fixed interim prostheses supported by two-stage threaded implants: Methodology and results
    • Schnitman DA, Wohrle PS, Rubenstein JE. Immediate fixed interim prostheses supported by two-stage threaded implants: methodology and results. J Oral Implantol 1990; 16:96-105.
    • (1990) J Oral Implantol , vol.16 , pp. 96-105
    • Schnitman, D.A.1    Wohrle, P.S.2    Rubenstein, J.E.3
  • 17
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage one surgery in edentulous arches. Ten consecutive case reports with 1 to 5 year data
    • Tarnow DP, Emitiag S, Classi A. Immediate loading of threaded implants at stage one surgery in edentulous arches. Ten consecutive case reports with 1 to 5 year data. Int J Oral Maxillofac Implants 1997; 12:319-324.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emitiag, S.2    Classi, A.3
  • 18
    • 0029348226 scopus 로고
    • Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - Technique reexamined: Two case reports
    • Salama H, Rose LF, Salama M, Betts NJ. Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - technique reexamined: two case reports. Int J Periodontics Restorative Dent 1995; 15:344-361.
    • (1995) Int J Periodontics Restorative Dent , vol.15 , pp. 344-361
    • Salama, H.1    Rose, L.F.2    Salama, M.3    Betts, N.J.4
  • 19
    • 0042961801 scopus 로고    scopus 로고
    • Anchored disk-design implants without bone augmentation in moderately to severely resorbed completely edentulous maxillae
    • Scortecci G. Anchored disk-design implants without bone augmentation in moderately to severely resorbed completely edentulous maxillae. J Oral Implant 1999; 25:37-79.
    • (1999) J Oral Implant , vol.25 , pp. 37-79
    • Scortecci, G.1
  • 20
    • 0033072986 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study
    • Randow R, Ericsson I, Nilner K, Petersson A, Glantz PO. Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study. Clin Oral Implants Res 1999; 10:8-15.
    • (1999) Clin Oral Implants Res , vol.10 , pp. 8-15
    • Randow, R.1    Ericsson, I.2    Nilner, K.3    Petersson, A.4    Glantz, P.O.5
  • 21
    • 0034326765 scopus 로고    scopus 로고
    • Immediate loading of Brånemark system implants following placement in edentulous patients: A clinical report
    • Horiuchi K, Uchida H, Yamamoto K, Sugimura M. Immediate loading of Brånemark system implants following placement in edentulous patients: a clinical report. Int J Oral Maxillofac Implants 2000; 15:824-830.
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 824-830
    • Horiuchi, K.1    Uchida, H.2    Yamamoto, K.3    Sugimura, M.4
  • 22
    • 0035350613 scopus 로고    scopus 로고
    • Immediate loading of implants with fixed restorations in the completely edentulous mandible: Report of 27 patients from a private practice
    • Ganeles J, Rosenberg MM, Holt RL, Rechman LH. Immediate loading of implants with fixed restorations in the completely edentulous mandible: report of 27 patients from a private practice. Int J Oral Maxillofac Implants 2001; 16:418-426.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 418-426
    • Ganeles, J.1    Rosenberg, M.M.2    Holt, R.L.3    Rechman, L.H.4
  • 23
    • 0034183762 scopus 로고    scopus 로고
    • Immediate loading of implants in partially and fully edentulous jaws: A series of 27 case reports
    • Jaffin RA, Kumar A, Berman CL. Immediate loading of implants in partially and fully edentulous jaws: a series of 27 case reports. J Periodontol 2000; 71:833-838.
    • (2000) J Periodontol , vol.71 , pp. 833-838
    • Jaffin, R.A.1    Kumar, A.2    Berman, C.L.3
  • 24
    • 0033067941 scopus 로고    scopus 로고
    • Mechanical properties of trabecular bone in the human mandible. Implications for dental implant treatment planning and surgical placement
    • Misch CE, Qu AL, Bidez MW. Mechanical properties of trabecular bone in the human mandible. Implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg 1999; 57:700-706.
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 700-706
    • Misch, C.E.1    Qu, A.L.2    Bidez, M.W.3
  • 25
    • 0032623338 scopus 로고    scopus 로고
    • A bone quality-based implant system: First year of prosthetic loading
    • Misch CE, Dietsh-Misch F, Hoar J, et al. A bone quality-based implant system: first year of prosthetic loading. J Oral Implantol 1999; 25:185-197.
    • (1999) J Oral Implantol , vol.25 , pp. 185-197
    • Misch, C.E.1    Dietsh-Misch, F.2    Hoar, J.3
  • 26
    • 0042460700 scopus 로고
    • Implant success or failure: Clinical assessment in implant dentistry
    • Misch CE, ed. St. Louis (MO): CV Mosby
    • Misch CE. Implant success or failure: clinical assessment in implant dentistry. In: Misch CE, ed. Contemporary implant dentistry. St. Louis (MO): CV Mosby, 1993:29-42.
    • (1993) Contemporary Implant Dentistry , pp. 29-42
    • Misch, C.E.1
  • 27
    • 18344407288 scopus 로고    scopus 로고
    • Implant quality scale: A clinical assessment of health-disease continuum
    • Misch CE. Implant quality scale: a clinical assessment of health-disease continuum. Oral Health 1998; July:18-26.
    • (1998) Oral Health , vol.JULY , pp. 18-26
    • Misch, C.E.1
  • 28
    • 0025617788 scopus 로고
    • Density of bone: Effect on treatment plans, surgical approach, healing and progressive bone loading
    • Misch CE. Density of bone: effect on treatment plans, surgical approach, healing and progressive bone loading. Int J Oral Implant 1990; 6(2):23-31.
    • (1990) Int J Oral Implant , vol.6 , Issue.2 , pp. 23-31
    • Misch, C.E.1
  • 32
    • 0020635205 scopus 로고
    • The regional acceleratory phenomenon: A review
    • Frost HM. The regional acceleratory phenomenon: a review. Henry Ford Hosp Med Bull 1983; 31:3-9.
    • (1983) Henry Ford Hosp Med Bull , vol.31 , pp. 3-9
    • Frost, H.M.1
  • 33
    • 0002043349 scopus 로고
    • The physiological and clinical significance of bone histomorphometric data
    • Reck RR, ed. Boca Raton (FL): CRC Press
    • Parfitt AM. The physiological and clinical significance of bone histomorphometric data. In: Reck RR, ed. Bone histomorphometry, techniques and interpretation. Boca Raton (FL): CRC Press, 1983:143-223.
    • (1983) Bone Histomorphometry, Techniques and Interpretation , pp. 143-223
    • Parfitt, A.M.1
  • 34
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone-dental implant interface: Review paper
    • Brunski JB. Biomechanical factors affecting the bone-dental implant interface: review paper. Clin Mater 1992; 10:153-201.
    • (1992) Clin Mater , vol.10 , pp. 153-201
    • Brunski, J.B.1
  • 35
  • 36
    • 0031107547 scopus 로고    scopus 로고
    • Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: A pilot study in monkeys
    • Piattelli A, Corigliano M, Scarano A, Quaranta M. Bone reactions to early occlusal loading of two-stage titanium plasma-sprayed implants: a pilot study in monkeys. Int J Periondontics Restorative Dent 1997; 17:162-169.
    • (1997) Int J Periondontics Restorative Dent , vol.17 , pp. 162-169
    • Piattelli, A.1    Corigliano, M.2    Scarano, A.3    Quaranta, M.4
  • 37
    • 0027830480 scopus 로고
    • An histologic and histomorphic-metric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: A pilot study
    • Piattelli A, Ruggeri A, Franchi M, Romasio N, Trisi P. An histologic and histomorphic-metric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: a pilot study. J Oral Implant 1993; 19:314-320.
    • (1993) J Oral Implant , vol.19 , pp. 314-320
    • Piattelli, A.1    Ruggeri, A.2    Franchi, M.3    Romasio, N.4    Trisi, P.5
  • 38
    • 0035319811 scopus 로고    scopus 로고
    • Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys
    • Romanos G, Tok CG, Sias CH, et al. Peri-implant bone reactions to immediately loaded implants. An experimental study in monkeys. J Periodontol 2001; 72:506-511.
    • (2001) J Periodontol , vol.72 , pp. 506-511
    • Romanos, G.1    Tok, C.G.2    Sias, C.H.3
  • 39
    • 0041458805 scopus 로고    scopus 로고
    • Endosteal implants in the edentulous posterior maxilla-rationale and clinical report
    • Misch CE, Poitras Y, Dietsh-Misch F. Endosteal implants in the edentulous posterior maxilla-rationale and clinical report. Oral Health 2000; August:7-16.
    • (2000) Oral Health , vol.AUGUST , pp. 7-16
    • Misch, C.E.1    Poitras, Y.2    Dietsh-Misch, F.3
  • 40
    • 85046173547 scopus 로고    scopus 로고
    • Radiographic assessment of peri-implant vertical bone loss: DICRG interim report no. 9
    • Manz MC. Radiographic assessment of peri-implant vertical bone loss: DICRG interim report no. 9. J Oral Maxillofac Surg 1996; 55:621-671.
    • (1996) J Oral Maxillofac Surg , vol.55 , pp. 621-671
    • Manz, M.C.1
  • 41
    • 0033301417 scopus 로고    scopus 로고
    • Astra Tech and Brånemark System implants: A prospective 5-year comparative study. Results after one year
    • Astrand P, Engquist B, Dahlgren S, et al. Astra Tech and Brånemark System implants: a prospective 5-year comparative study. Results after one year. Clin Implant Dent Relat Res 1999; 1(1):17-26.
    • (1999) Clin Implant Dent Relat Res , vol.1 , Issue.1 , pp. 17-26
    • Astrand, P.1    Engquist, B.2    Dahlgren, S.3
  • 42
    • 0028186993 scopus 로고
    • Longitudinal radiographic study of crestal bone levels adjacent to non-submerged dental implants
    • Pham AN, Fiorellini JP, Paquette D, et al. Longitudinal radiographic study of crestal bone levels adjacent to non-submerged dental implants. J Oral Implantol 1994; 20(1):26-34.
    • (1994) J Oral Implantol , vol.20 , Issue.1 , pp. 26-34
    • Pham, A.N.1    Fiorellini, J.P.2    Paquette, D.3
  • 43
    • 0027564377 scopus 로고
    • The effects of early occlusal loading in one-stage titanium alloy implants in beagle dogs: A pilot study
    • Sagara M, Akagawa Y, Nikai H, Tsury H. The effects of early occlusal loading in one-stage titanium alloy implants in beagle dogs: a pilot study. J Prosthet Dent 1993; 69:281-288.
    • (1993) J Prosthet Dent , vol.69 , pp. 281-288
    • Sagara, M.1    Akagawa, Y.2    Nikai, H.3    Tsury, H.4
  • 44
    • 0029439224 scopus 로고
    • Remodeling dynamics of bone supporting rigidly fixated titanium implants: A histomorphometric comparison of four species including humans
    • Garetto LP, Chen J, Parr JA, Roberts WE. Remodeling dynamics of bone supporting rigidly fixated titanium implants: a histomorphometric comparison of four species including humans. Implant Dent 1995; 4:235-243.
    • (1995) Implant Dent , vol.4 , pp. 235-243
    • Garetto, L.P.1    Chen, J.2    Parr, J.A.3    Roberts, W.E.4
  • 45
    • 0034577012 scopus 로고    scopus 로고
    • Preliminary evaluation of new dental implant design in canine models
    • Baumgardner JD, Boring JG, Cooper RC, et al. Preliminary evaluation of new dental implant design in canine models. Implant Dent 2000; 9:252-260.
    • (2000) Implant Dent , vol.9 , pp. 252-260
    • Baumgardner, J.D.1    Boring, J.G.2    Cooper, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.