메뉴 건너뛰기




Volumn 14, Issue 3, 2003, Pages 312-321

Bone contact, growth, and density around immediately loaded implants in the mandible of mini pigs

Author keywords

Bone to implant contact; Fixed provisional restoration; Fluorescence microscopy; Immediate loading; Partially edentulous mandible

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; BONE DENSITY; BONE GROWTH; BONE MINERALIZATION; CONTROLLED STUDY; DENTAL SURGERY; EDENTULOUSNESS; EXPERIMENTAL MODEL; FEMALE; FLUORESCENCE; HISTOLOGY; MANDIBLE; MASTICATION; MORPHOMETRICS; NONHUMAN; PREMOLAR TOOTH; SWINE; TOOTH IMPLANTATION; TREATMENT FAILURE; TREATMENT OUTCOME; WOUND HEALING; ANIMAL; BONE DEVELOPMENT; BONE REGENERATION; COMPARATIVE STUDY; DENTURE; MINIPIG; NONPARAMETRIC TEST; PATHOLOGY; PHYSIOLOGY; SURFACE PROPERTY; TOOTH PROSTHESIS; WEIGHT BEARING;

EID: 0041881772     PISSN: 09057161     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0501.2003.120906.x     Document Type: Article
Times cited : (98)

References (51)
  • 1
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson, T., Brånemark, P.I., Hansson, H.A. & Lindstrom, J. (1981) Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthopaedica Scandinavica 52: 155-170.
    • (1981) Acta Orthopaedica Scandinavica , vol.52 , pp. 155-170
    • Albrektsson, T.1    Brånemark, P.I.2    Hansson, H.A.3    Lindstrom, J.4
  • 2
    • 0022467575 scopus 로고
    • Titanium plasma sprayed screw implants for the reconstruction of the edentulous mandible
    • Babbush, C.A., Kent, J.N. & Misiek, D.J. (1986) Titanium plasma sprayed screw implants for the reconstruction of the edentulous mandible. Journal of Oral and Maxillofacial Surgery 44: 274-282.
    • (1986) Journal of Oral and Maxillofacial Surgery , vol.44 , pp. 274-282
    • Babbush, C.A.1    Kent, J.N.2    Misiek, D.J.3
  • 3
    • 0020823258 scopus 로고
    • Osseointegration and its theoretical background
    • Brånemark, P.I. (1983) Osseointegration and its theoretical background. Journal of Prosthetic Dentistry 50: 399-410.
    • (1983) Journal of Prosthetic Dentistry , vol.50 , pp. 399-410
    • Brånemark, P.I.1
  • 5
    • 0026740505 scopus 로고
    • Biomechanical factors affecting the bone-dental implant interface: Review paper
    • Brunski, J.B. (1992) Biomechanical factors affecting the bone-dental implant interface: review paper. Clinical Materials 10: 153-201.
    • (1992) Clinical Materials , vol.10 , pp. 153-201
    • Brunski, J.B.1
  • 6
    • 0027683837 scopus 로고
    • Avoid pitfalls of overloading and micromotion of intraosseous implants
    • Brunski, J.B. (1993) Avoid pitfalls of overloading and micromotion of intraosseous implants. Dental Implantology Update 4: 77-81.
    • (1993) Dental Implantology Update , vol.4 , pp. 77-81
    • Brunski, J.B.1
  • 7
    • 0018564497 scopus 로고
    • The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects
    • Brunski, J.B., Moccia, A.F. Jr, Pollack, S.R., Korostoff, E. & Trachtenberg, D.I. (1979) The influence of functional use of endosseous dental implants on the tissue-implant interface. I. Histological aspects. Journal of Dental Research 58: 1953-1969.
    • (1979) Journal of Dental Research , vol.58 , pp. 1953-1969
    • Brunski, J.B.1    Moccia Jr., A.F.2    Pollack, S.R.3    Korostoff, E.4    Trachtenberg, D.I.5
  • 8
    • 0002740053 scopus 로고
    • Effect of mechanical stress on tissue differentiation in the bony implant bed
    • Davies, J.E., Ed. Toronto: Toronto University Press
    • Carter, D.R. & Giori, N.J. (1991) Effect of mechanical stress on tissue differentiation in the bony implant bed. IN: DAVIES, J.E., ED. THE BIOMATERIAL INTERFACE, 1ST EDN., PP. 367-379, TORONTO: TORONTO UNIVERSITY PRESS.
    • (1991) The Biomaterial Interface, 1st Edn. , pp. 367-379
    • Carter, D.R.1    Giori, N.J.2
  • 9
    • 0031061750 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases
    • Chiapasco, M., Gatti, C., Rossi, E., Haefliger, W. & Markwalder, T.H. (1997) Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases. Clinical Oral Implants Research 8: 48-57.
    • (1997) Clinical Oral Implants Research , vol.8 , pp. 48-57
    • Chiapasco, M.1    Gatti, C.2    Rossi, E.3    Haefliger, W.4    Markwalder, T.H.5
  • 10
    • 0033209666 scopus 로고    scopus 로고
    • Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs
    • Corso, M., Sirota, C., Fiorellini, J., Rasool, F., Szmukler-Moncler, S. & Weber, H.P. (1999) Clinical and radiographic evaluation of early loaded free-standing dental implants with various coatings in beagle dogs. Journal of Prosthetic Dentistry 82: 428-435.
    • (1999) Journal of Prosthetic Dentistry , vol.82 , pp. 428-435
    • Corso, M.1    Sirota, C.2    Fiorellini, J.3    Rasool, F.4    Szmukler-Moncler, S.5    Weber, H.P.6
  • 11
    • 0002430242 scopus 로고
    • Tissue reactions around loaded and unloaded titanium implants
    • Donath, K. (1993) Tissue reactions around loaded and unloaded titanium implants. Journal of Hard Tissue Biology 2: 37-47.
    • (1993) Journal of Hard Tissue Biology , vol.2 , pp. 37-47
    • Donath, K.1
  • 12
    • 0019947037 scopus 로고
    • A method for the study of undecalcified bones and teeth with attached soft tissues. The sawing and grinding technique
    • Donath, K. & Breuner, G. (1982) A method for the study of undecalcified bones and teeth with attached soft tissues. The sawing and grinding technique. Journal of Oral Pathology 11: 318-326.
    • (1982) Journal of Oral Pathology , vol.11 , pp. 318-326
    • Donath, K.1    Breuner, G.2
  • 13
    • 0033622817 scopus 로고    scopus 로고
    • Quantifying the strain history of bone: Spatial uniformity and self-similarity of low-magnitude strains
    • Fritton, S.P., McLeod, K.J. & Rubin, C.T. (2000) Quantifying the strain history of bone: spatial uniformity and self-similarity of low-magnitude strains. Journal of Biomechanics 33: 317-325.
    • (2000) Journal of Biomechanics , vol.33 , pp. 317-325
    • Fritton, S.P.1    McLeod, K.J.2    Rubin, C.T.3
  • 14
    • 0026554157 scopus 로고
    • The role of changes in mechanical usage set points in the pathogenesis of osteoporosis
    • Frost, H.M. (1992) The role of changes in mechanical usage set points in the pathogenesis of osteoporosis. Journal of Bone and Mineral Research 7: 253-261.
    • (1992) Journal of Bone and Mineral Research , vol.7 , pp. 253-261
    • Frost, H.M.1
  • 15
    • 0035350613 scopus 로고    scopus 로고
    • Immediate loading of implants with fixed restorations in the completely edentulous mandible: Report of 27 patients from a private practice
    • Ganeles, J., Rosenberg, M.M., Holt, R.L. & Reichman, L.H. (2001) Immediate loading of implants with fixed restorations in the completely edentulous mandible: report of 27 patients from a private practice. International Journal of Oral and Maxillofacial Implants 16: 418-426.
    • (2001) International Journal of Oral and Maxillofacial Implants , vol.16 , pp. 418-426
    • Ganeles, J.1    Rosenberg, M.M.2    Holt, R.L.3    Reichman, L.H.4
  • 16
    • 0034186403 scopus 로고    scopus 로고
    • Implant-retained mandibular overdentures with immediate loading: A prospective study of ITI implants
    • Gatti, C., Haeflinger, W. & Chiapasco, M. (2000) Implant-retained mandibular overdentures with immediate loading: a prospective study of ITI implants. International Journal of Maxillofacial Implants 15: 383-388.
    • (2000) International Journal of Maxillofacial Implants , vol.15 , pp. 383-388
    • Gatti, C.1    Haeflinger, W.2    Chiapasco, M.3
  • 17
    • 0005676804 scopus 로고
    • The Göttingen mini pig as experimental animal in the human medical osteologic fundamental research
    • Honig, J.F. & Merten, H.A. (1993) The Göttingen mini pig as experimental animal in the human medical osteologic fundamental research. Zeitschrift für Zahnärztliche Implantologie 2: 237-243.
    • (1993) Zeitschrift für Zahnärztliche Implantologie , vol.2 , pp. 237-243
    • Honig, J.F.1    Merten, H.A.2
  • 20
    • 0030155740 scopus 로고    scopus 로고
    • Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits
    • Ivanoff, C.J., Sennerby, L. & Lekholm, U. (1996) Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits. Clinical Oral Implants Research 7: 120-127.
    • (1996) Clinical Oral Implants Research , vol.7 , pp. 120-127
    • Ivanoff, C.J.1    Sennerby, L.2    Lekholm, U.3
  • 21
    • 0034183762 scopus 로고    scopus 로고
    • Immediate loading of implants in partially and fully edentulous jaws: A series of 27 case reports
    • Jaffin, R.A., Kumar, A. & Berman, C.L. (2000) Immediate loading of implants in partially and fully edentulous jaws: a series of 27 case reports. International Journal of Periodontology 71: 833-838.
    • (2000) International Journal of Periodontology , vol.71 , pp. 833-838
    • Jaffin, R.A.1    Kumar, A.2    Berman, C.L.3
  • 22
    • 0023302919 scopus 로고
    • Integration of screw implants in the rabbit: A 1-year follow-up of removal torque of titanium implants
    • Johansson, C. & Albrektsson, T. (1987) Integration of screw implants in the rabbit: a 1-year follow-up of removal torque of titanium implants. International Journal of Oral and Maxillofacial Implants 2: 69-75.
    • (1987) International Journal of Oral and Maxillofacial Implants , vol.2 , pp. 69-75
    • Johansson, C.1    Albrektsson, T.2
  • 24
    • 0012443968 scopus 로고    scopus 로고
    • More than 20 years of experience with immediate loading of implant borne cantilever prostheses in the interforaminal region
    • Ledermann, P.D. (1996) More than 20 years of experience with immediate loading of implant borne cantilever prostheses in the interforaminal region. Zeitschrift für Zahnärztliche Implantologie 12: 123-136.
    • (1996) Zeitschrift für Zahnärztliche Implantologie , vol.12 , pp. 123-136
    • Ledermann, P.D.1
  • 27
    • 0026266915 scopus 로고
    • Histologic evaluation of hydroxylapatite-coated versus uncoated titanium blade implants in delayed and immediately loaded applications
    • Lum, L.B., Beime, O.R. & Curtis, D.A. (1991) Histologic evaluation of hydroxylapatite-coated versus uncoated titanium blade implants in delayed and immediately loaded applications. International Journal of Oral and Maxillofacial Implants 6: 456-462.
    • (1991) International Journal of Oral and Maxillofacial Implants , vol.6 , pp. 456-462
    • Lum, L.B.1    Beime, O.R.2    Curtis, D.A.3
  • 28
    • 0034574209 scopus 로고    scopus 로고
    • Immediate function of Brånemark implants in the esthetic zone: A retrospective clinical study with 6 months to 4 years of follow-up
    • Malo, P., Rangert, B. & Dvarsater, L. (2000) Immediate function of Brånemark implants in the esthetic zone: a retrospective clinical study with 6 months to 4 years of follow-up. Clinical Implant Dentistry and Related Research 2: 138-146.
    • (2000) Clinical Implant Dentistry and Related Research , vol.2 , pp. 138-146
    • Malo, P.1    Rangert, B.2    Dvarsater, L.3
  • 29
    • 0034252660 scopus 로고    scopus 로고
    • Pulsed electromagnetic fields promote bone formation around dental implants inserted into the femur of rabbits
    • Matsumoto, H., Ochi, M., Abiko, Y., Hirose, Y., Kaku, T. & Sakaguchi, K. (2000) Pulsed electromagnetic fields promote bone formation around dental implants inserted into the femur of rabbits. Clinical Oral Implants Research 11: 354-360.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 354-360
    • Matsumoto, H.1    Ochi, M.2    Abiko, Y.3    Hirose, Y.4    Kaku, T.5    Sakaguchi, K.6
  • 32
    • 0030981647 scopus 로고    scopus 로고
    • Immediate loading of titanium plasma-sprayed screw-shaped implants in man: A clinical and histological report of two cases
    • Piattelli, A., Paolantonio, M., Corigliano, M. & Scarano, A. (1997) Immediate loading of titanium plasma-sprayed screw-shaped implants in man: a clinical and histological report of two cases. International Journal of Periodontology 68: 591-597.
    • (1997) International Journal of Periodontology , vol.68 , pp. 591-597
    • Piattelli, A.1    Paolantonio, M.2    Corigliano, M.3    Scarano, A.4
  • 35
    • 0022465758 scopus 로고
    • Observations on the effect of movement on bone ingrowth into porous-surfaced implants
    • Pilliar, R.M., Lee, J.M. & Maniatopoulos, C. (1986) Observations on the effect of movement on bone ingrowth into porous-surfaced implants. Clinical Orthopedics 208: 108-113.
    • (1986) Clinical Orthopedics , vol.208 , pp. 108-113
    • Pilliar, R.M.1    Lee, J.M.2    Maniatopoulos, C.3
  • 36
    • 0033072986 scopus 로고    scopus 로고
    • Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study
    • Randow, K., Ericsson, J., Nilner, K., Petersson, A. & Glantz, P.O. (1999) Immediate functional loading of Brånemark dental implants. An 18-month clinical follow-up study. Clinical Oral Implants Research 10: 9-15.
    • (1999) Clinical Oral Implants Research , vol.10 , pp. 9-15
    • Randow, K.1    Ericsson, J.2    Nilner, K.3    Petersson, A.4    Glantz, P.O.5
  • 38
    • 0027564377 scopus 로고
    • The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: A pilot study
    • Sagara, M., Akagawa, Y., Nikai, H. & Tsuru, H. (1993) The effects of early occlusal loading on one-stage titanium alloy implants in beagle dogs: a pilot study. Journal of Prosthetic Dentistry 69: 281-288.
    • (1993) Journal of Prosthetic Dentistry , vol.69 , pp. 281-288
    • Sagara, M.1    Akagawa, Y.2    Nikai, H.3    Tsuru, H.4
  • 39
    • 0029348226 scopus 로고
    • Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - A technique re-examined: Two case reports
    • Salama, H., Rose, L.F., Salama, M. & Betts, N.J. (1995) Immediate loading of bilaterally splinted titanium root-form implants in fixed prosthodontics - a technique re-examined: two case reports. International Journal of Periodontology and Restorative Dentistry 15: 345-361.
    • (1995) International Journal of Periodontology and Restorative Dentistry , vol.15 , pp. 345-361
    • Salama, H.1    Rose, L.F.2    Salama, M.3    Betts, N.J.4
  • 41
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak, R. (1983) Biomechanical considerations in osseointegrated prostheses. Journal of Prosthetic Dentistry 49: 843-848.
    • (1983) Journal of Prosthetic Dentistry , vol.49 , pp. 843-848
    • Skalak, R.1
  • 42
    • 0031458468 scopus 로고    scopus 로고
    • Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits
    • Suzuki, K., Aoki, K. & Ohya, K. (1997) Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits. Bone 21: 507-514.
    • (1997) Bone , vol.21 , pp. 507-514
    • Suzuki, K.1    Aoki, K.2    Ohya, K.3
  • 43
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler, S., Piattelli, A., Favero, G.A. & Dubruille, J.H. (2000) Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clinical Oral Implants Research 11: 12-25.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 44
    • 0034252926 scopus 로고    scopus 로고
    • Histological observations on biopsies harvested following sinus floor elevation using a bioactive glass material of narrow size range
    • Tadjoedin, E.T., De Lange, G.L., Holzmann, P.J., Kuiper, L. & Burger, E.H. (2000) Histological observations on biopsies harvested following sinus floor elevation using a bioactive glass material of narrow size range. Clinical Oral Implants Research 11: 334-344.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 334-344
    • Tadjoedin, E.T.1    De Lange, G.L.2    Holzmann, P.J.3    Kuiper, L.4    Burger, E.H.5
  • 45
    • 0031136510 scopus 로고    scopus 로고
    • Immediate loading of threaded implants at stage 1 surgery in edentulous arches: Ten consecutive case reports with 1- to 5-year data
    • Tarnow, D.P., Emtiaz, S. & Classi, A. (1997) Immediate loading of threaded implants at stage 1 surgery in edentulous arches: ten consecutive case reports with 1-to 5-year data. International Journal of Oral and Maxillofacial Implants 12: 319-324.
    • (1997) International Journal of Oral and Maxillofacial Implants , vol.12 , pp. 319-324
    • Tarnow, D.P.1    Emtiaz, S.2    Classi, A.3
  • 47
    • 0032601842 scopus 로고    scopus 로고
    • Factors affecting heat generation during implant site preparation: A review of biologic observations and future considerations
    • Tehemar, S.H. (1999) Factors affecting heat generation during implant site preparation: a review of biologic observations and future considerations. International Journal of Oral and Maxillofacial Implants 14: 127-136.
    • (1999) International Journal of Oral and Maxillofacial Implants , vol.14 , pp. 127-136
    • Tehemar, S.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.