-
1
-
-
0026167719
-
Early failures of 4641 consecutively installed Brånemark dental implants. I. A study from stage one surgery to installation of the completed prosthesis
-
Friberg B, Jemt T, Lekholm U. Early failures of 4641 consecutively installed Brånemark dental implants. I. A study from stage one surgery to installation of the completed prosthesis. Int J Oral Maxillofac Implants 1991;6:142-146.
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, pp. 142-146
-
-
Friberg, B.1
Jemt, T.2
Lekholm, U.3
-
2
-
-
0020531670
-
Errors in measuring trabecular bone by computerized tomography due to marrow and bone composition
-
Mazess RB. Errors in measuring trabecular bone by computerized tomography due to marrow and bone composition. Calcif Tissue Int 1983;35:148-152.
-
(1983)
Calcif Tissue Int
, vol.35
, pp. 148-152
-
-
Mazess, R.B.1
-
3
-
-
0032018553
-
A comparison of maxillary and mandibular bone mineral densities
-
Devlin H, Horner K, Ledgerton K. A comparison of maxillary and mandibular bone mineral densities. J Prosthet Dent 1998;79:323-327.
-
(1998)
J Prosthet Dent
, vol.79
, pp. 323-327
-
-
Devlin, H.1
Horner, K.2
Ledgerton, K.3
-
4
-
-
0029314564
-
Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. A one-year longitudinal study
-
Mericske-Stern R, Milani D, Mericske E, Olah A. Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. A one-year longitudinal study. Clin Oral Implants Res 1995;6:73-82.
-
(1995)
Clin Oral Implants Res
, vol.6
, pp. 73-82
-
-
Mericske-Stern, R.1
Milani, D.2
Mericske, E.3
Olah, A.4
-
6
-
-
0027460745
-
Histologic investigations on 33 retrieved Nobelpharma implants
-
Albrektsson T, Eriksson AR, Friberg B, Lekholm U, Lindahl L, Nevins M, et al. Histologic investigations on 33 retrieved Nobelpharma implants. Clin Mater 1993;12:1-9.
-
(1993)
Clin Mater
, vol.12
, pp. 1-9
-
-
Albrektsson, T.1
Eriksson, A.R.2
Friberg, B.3
Lekholm, U.4
Lindahl, L.5
Nevins, M.6
-
7
-
-
0027347181
-
Treatment of the severely resorbed maxillae with bone graft and titanium implants: Histologic review of autopsy specimens
-
Nystrom E, Kahnberg K-E, Albrektsson T. Treatment of the severely resorbed maxillae with bone graft and titanium implants: Histologic review of autopsy specimens. Int J Oral Maxillofac Implants 1993;8:167-172.
-
(1993)
Int J Oral Maxillofac Implants
, vol.8
, pp. 167-172
-
-
Nystrom, E.1
Kahnberg, K.-E.2
Albrektsson, T.3
-
9
-
-
0025654203
-
The Periotest method as a measure of osseointegrated oral implant stability
-
Olivé J, Aparicio C. The Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants 1990;5:390-400.
-
(1990)
Int J Oral Maxillofac Implants
, vol.5
, pp. 390-400
-
-
Olivé, J.1
Aparicio, C.2
-
10
-
-
0031261491
-
Quantitative histomorphometric description of implant anchorage for three types of dental implants following 3 months of healing in baboons
-
Carr AB, Gerard DA, Larsen PE. Quantitative histomorphometric description of implant anchorage for three types of dental implants following 3 months of healing in baboons. Int J Oral Maxillofac Implants 1997;12:777-784.
-
(1997)
Int J Oral Maxillofac Implants
, vol.12
, pp. 777-784
-
-
Carr, A.B.1
Gerard, D.A.2
Larsen, P.E.3
-
11
-
-
0032020059
-
Effects of steroid-induced osteoporosis on osseointegration of titanium implants
-
Fujimoto T, Niimi A, Sawai T, Ueda M. Effects of steroid-induced osteoporosis on osseointegration of titanium implants. Int J Oral Maxillofac Implants 1998;13:183-189.
-
(1998)
Int J Oral Maxillofac Implants
, vol.13
, pp. 183-189
-
-
Fujimoto, T.1
Niimi, A.2
Sawai, T.3
Ueda, M.4
-
12
-
-
0026301882
-
A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and Vitallium implants
-
Johansson CB, Sennerby L, Albrektsson T. A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and Vitallium implants. Int J Oral Maxillofac Implants 1991;6:437-441.
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, pp. 437-441
-
-
Johansson, C.B.1
Sennerby, L.2
Albrektsson, T.3
-
13
-
-
0031132982
-
The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: An experimental animal study
-
Caulier H, Naert I, Kalk W, Jansen JA. The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: An experimental animal study. Int J Oral Maxillofac Implants 1997;12:380-386.
-
(1997)
Int J Oral Maxillofac Implants
, vol.12
, pp. 380-386
-
-
Caulier, H.1
Naert, I.2
Kalk, W.3
Jansen, J.A.4
-
14
-
-
0030208388
-
The three-dimensional bone interface of an osseointegrated implant. II: A morphometric evaluation after three months of loading
-
Sahin S, Akagawa Y, Wadamoto M, Sato Y. The three-dimensional bone interface of an osseointegrated implant. II: A morphometric evaluation after three months of loading. J Prosthet Dent 1996;76:176-180.
-
(1996)
J Prosthet Dent
, vol.76
, pp. 176-180
-
-
Sahin, S.1
Akagawa, Y.2
Wadamoto, M.3
Sato, Y.4
-
15
-
-
0031458468
-
Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits
-
Suzuki K, Aoki K, Ohya K. Effects of surface roughness of titanium implants on bone remodeling activity of femur in rabbits. Bone 1997;21:507-514.
-
(1997)
Bone
, vol.21
, pp. 507-514
-
-
Suzuki, K.1
Aoki, K.2
Ohya, K.3
-
16
-
-
0031244133
-
Short- And long-term animal studies with a plasma-sprayed calcium phosphate-coated implant
-
Gottlander M, Johansson CB, Albrektsson T. Short-and long-term animal studies with a plasma-sprayed calcium phosphate-coated implant. Clin Oral Implants Res 1997;8: 345-351.
-
(1997)
Clin Oral Implants Res
, vol.8
, pp. 345-351
-
-
Gottlander, M.1
Johansson, C.B.2
Albrektsson, T.3
-
17
-
-
0026300431
-
Histomorphometric studies of hydroxyapatite-coated and uncoated CP titanium threaded implants in bone
-
Gottlander M. Albrektsson T. Histomorphometric studies of hydroxyapatite-coated and uncoated CP titanium threaded implants in bone. Int J Oral Maxillofac Implants 1991;6: 399-404.
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, pp. 399-404
-
-
Gottlander, M.1
Albrektsson, T.2
-
19
-
-
0027830480
-
A histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: A pilot study
-
Piattelli A, Ruggeri A, Franchi M, Romasco N, Trisi P. A histologic and histomorphometric study of bone reactions to unloaded and loaded non-submerged single implants in monkeys: A pilot study. J Oral Implantol 1993;19:314-320.
-
(1993)
J Oral Implantol
, vol.19
, pp. 314-320
-
-
Piattelli, A.1
Ruggeri, A.2
Franchi, M.3
Romasco, N.4
Trisi, P.5
-
20
-
-
0031173845
-
Histologic evaluation of the LaminOss osteocompressive dental screw: A pilot study
-
Block CM, Tillmanns HWS, Meffert RM. Histologic evaluation of the LaminOss osteocompressive dental screw: A pilot study. Compendium 1997;18:676-685.
-
(1997)
Compendium
, vol.18
, pp. 676-685
-
-
Block, C.M.1
Tillmanns, H.W.S.2
Meffert, R.M.3
-
21
-
-
0032163977
-
Reactions of peri-implant tissues to continuous loading of osseointegrated implants
-
Akin-Nergiz N, Nergiz I, Schulz A, Arpak N, Niedermeier W. Reactions of peri-implant tissues to continuous loading of osseointegrated implants. Am J Orthod Dentofac Orthop 1998;114:292-298.
-
(1998)
Am J Orthod Dentofac Orthop
, vol.114
, pp. 292-298
-
-
Akin-Nergiz, N.1
Nergiz, I.2
Schulz, A.3
Arpak, N.4
Niedermeier, W.5
-
22
-
-
0032062138
-
A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone
-
Johansson CB, Han CH, Wennerberg A, Albrektsson T. A quantitative comparison of machined commercially pure titanium and titanium-aluminum-vanadium implants in rabbit bone. Int J Oral Maxillofac Implants 1998;13:315-321.
-
(1998)
Int J Oral Maxillofac Implants
, vol.13
, pp. 315-321
-
-
Johansson, C.B.1
Han, C.H.2
Wennerberg, A.3
Albrektsson, T.4
-
23
-
-
0022622197
-
Inter-observer and intra-observer variation in bone histomorphometry
-
Compston JE, Vedi S, Stellon AJ. Inter-observer and intra-observer variation in bone histomorphometry. Calcif Tissue Int 1986;38:67-70.
-
(1986)
Calcif Tissue Int
, vol.38
, pp. 67-70
-
-
Compston, J.E.1
Vedi, S.2
Stellon, A.J.3
-
24
-
-
0029088572
-
Technical note: Cutting directions of bone with biomaterials in situ does influence the outcome of histomorphometrical quantifications
-
Johansson CB, Morberg P. Technical note: Cutting directions of bone with biomaterials in situ does influence the outcome of histomorphometrical quantifications. Biomaterials 1995;16:1037-1039.
-
(1995)
Biomaterials
, vol.16
, pp. 1037-1039
-
-
Johansson, C.B.1
Morberg, P.2
-
25
-
-
0031255424
-
Effects of guided bone regeneration around commercially pure titanium and hydroxyapatite-coated dental implants. II. Histologic analysis
-
Stentz WC, Mealey BL, Gunsolley JC, Waldrop TC. Effects of guided bone regeneration around commercially pure titanium and hydroxyapatite-coated dental implants. II. Histologic analysis. J Periodontol 1997;68:933-949.
-
(1997)
J Periodontol
, vol.68
, pp. 933-949
-
-
Stentz, W.C.1
Mealey, B.L.2
Gunsolley, J.C.3
Waldrop, T.C.4
-
26
-
-
0027022484
-
Histomorphometry of bone apposition around three types of endosseous dental implants
-
Weinlaender M, Kenney EB, Lekovic V, Beumer J, Moy PK, Lewis S. Histomorphometry of bone apposition around three types of endosseous dental implants. Int J Oral Maxillofac Implants 1992;7:491-496.
-
(1992)
Int J Oral Maxillofac Implants
, vol.7
, pp. 491-496
-
-
Weinlaender, M.1
Kenney, E.B.2
Lekovic, V.3
Beumer, J.4
Moy, P.K.5
Lewis, S.6
-
27
-
-
0030144779
-
Loaded and nonloaded titanium versus hydroxyapatite-coated threaded implants in the canine mandible
-
Evans GH, Mendez AJ, Caudill RE. Loaded and nonloaded titanium versus hydroxyapatite-coated threaded implants in the canine mandible. Int J Oral Maxillofac Implants 1996;11: 360-371.
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 360-371
-
-
Evans, G.H.1
Mendez, A.J.2
Caudill, R.E.3
-
28
-
-
0026245670
-
The effect of partial coating with hydroxyapatite on bone remodeling in relation to porous-coated titanium-alloy dental implants in the dog
-
Pilliar RM, Deporter DA, Watson PA, Pharoah M, Chipman M, Valiquette N, et al. The effect of partial coating with hydroxyapatite on bone remodeling in relation to porous-coated titanium-alloy dental implants in the dog. J Dent Res 1970;10:1338-1345.
-
(1970)
J Dent Res
, vol.10
, pp. 1338-1345
-
-
Pilliar, R.M.1
Deporter, D.A.2
Watson, P.A.3
Pharoah, M.4
Chipman, M.5
Valiquette, N.6
-
29
-
-
0025717619
-
Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkeys
-
Gotfredsen K, Rostrup E, Hjørting-Hansen E, Stoltze K, Budtz-Jorgensen E. Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkeys. Clin Oral Implants Res 1991;2:30-37.
-
(1991)
Clin Oral Implants Res
, vol.2
, pp. 30-37
-
-
Gotfredsen, K.1
Rostrup, E.2
Hjørting-Hansen, E.3
Stoltze, K.4
Budtz-Jorgensen, E.5
-
30
-
-
0029268053
-
A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies
-
Wennerberg A, Albrektsson T, Andersson B, Krol JJ. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies. Clin Oral Implants Res 1995;6:24-30.
-
(1995)
Clin Oral Implants Res
, vol.6
, pp. 24-30
-
-
Wennerberg, A.1
Albrektsson, T.2
Andersson, B.3
Krol, J.J.4
-
33
-
-
0031244133
-
Short- And long-term animal studies with a plasma-sprayed calcium phosphate-coated implant
-
Gottlander M, Johansson CB, Albrektsson T. Short-and long-term animal studies with a plasma-sprayed calcium phosphate-coated implant. Clin Oral Implants Res 1997;8: 345-351.
-
(1997)
Clin Oral Implants Res
, vol.8
, pp. 345-351
-
-
Gottlander, M.1
Johansson, C.B.2
Albrektsson, T.3
-
34
-
-
0033210930
-
Bone tissue reaction around implants placed in a compromised jaw
-
Carmagnola D, Araujo M, Berglundh T, Albrektsson T, Lindhe J. Bone tissue reaction around implants placed in a compromised jaw. J Clin Periodontol 1999;26:629-635.
-
(1999)
J Clin Periodontol
, vol.26
, pp. 629-635
-
-
Carmagnola, D.1
Araujo, M.2
Berglundh, T.3
Albrektsson, T.4
Lindhe, J.5
-
35
-
-
0033069809
-
Recombinant human bone morphogenetic protein-2 stimulation of bone formation around endosseous dental implants
-
Cochran DL, Schenk R, Buser D, Wozney JM, Jones AA. Recombinant human bone morphogenetic protein-2 stimulation of bone formation around endosseous dental implants. J Periodontol 1999;70:139-150.
-
(1999)
J Periodontol
, vol.70
, pp. 139-150
-
-
Cochran, D.L.1
Schenk, R.2
Buser, D.3
Wozney, J.M.4
Jones, A.A.5
|