메뉴 건너뛰기




Volumn 28, Issue 1, 2003, Pages 59-71

Accuracy and repeatability of cementless total hip replacement surgery in patients with deformed anatomies

Author keywords

Computer aided surgery; Hip prosthesis; Planned vs. Achieved accuracy; Surgical planning

Indexed keywords

BONE CEMENT;

EID: 0038720102     PISSN: 14639238     EISSN: None     Source Type: Journal    
DOI: 10.1080/1463923031000124128     Document Type: Article
Times cited : (17)

References (32)
  • 1
    • 0024957917 scopus 로고
    • Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants
    • Bargar, W. L., 1989, Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants. Clinical Orthopaedics and Related Research, 249, 73-78.
    • (1989) Clinical Orthopaedics and Related Research , vol.249 , pp. 73-78
    • Bargar, W.L.1
  • 2
    • 0034308101 scopus 로고    scopus 로고
    • Hippin: A semiautomatic computer program for selecting hip prosthesis femoral components
    • Bongini, D., Carfagni, M. and Governi, L. 2000, Hippin: a semiautomatic computer program for selecting hip prosthesis femoral components. Computer Methods and Programs in Biomedicine, 2, 105-115, 63.
    • (2000) Computer Methods and Programs in Biomedicine , vol.2 , Issue.63 , pp. 105-115
    • Bongini, D.1    Carfagni, M.2    Governi, L.3
  • 4
    • 0003783331 scopus 로고    scopus 로고
    • Design and evaluation of 3-D pre-operative planning software: Application to acetabular implant alignment
    • Robotics Institute of Carnegie Mellon University Technical paper
    • Blackwell, M., Simon, D., Rao, S. and DiGioia, A. M. 1996, Design and evaluation of 3-D pre-operative planning software: application to acetabular implant alignment. Robotics Institute of Carnegie Mellon University Technical paper.
    • (1996)
    • Blackwell, M.1    Simon, D.2    Rao, S.3    DiGioia, A.M.4
  • 6
    • 84872239557 scopus 로고    scopus 로고
    • Efficacy of robot-assisted hip stem implantation. A radiographic comparison of matched-pair femurs prepared manually and with the Robodoc system using an anatomic prosthesis
    • MICCAI 2000 Pittsburgh, PA. 11-14 October 2000
    • Gossé, F., Wenger, K. H., Knabe, K. and Wirth, C. J., 2000, Efficacy of robot-assisted hip stem implantation. A radiographic comparison of matched-pair femurs prepared manually and with the Robodoc system using an anatomic prosthesis. Proceedings of Medical Image Computing and Computer-Assisted Intervention, MICCAI 2000, Pittsburgh, PA. 11-14 October 2000, pp. 1180-1184.
    • (2000) Proceedings of Medical Image Computing and Computer-Assisted Intervention , pp. 1180-1184
    • Gossé, F.1    Wenger, K.H.2    Knabe, K.3    Wirth, C.J.4
  • 8
    • 84956694744 scopus 로고    scopus 로고
    • Range of motion after total hip arthroplasty: Experimental verification of the analytical simulator
    • Grenoble. 1997
    • Jaramaz, B., Nikou, C., Simon, D. and DiGioia, A. M. 1997, Range of motion after total hip arthroplasty: experimental verification of the analytical simulator. Proceedings of First Joint CVRMed/MRCAS Conference, Grenoble. 1997, pp. 573-582.
    • (1997) Proceedings of First Joint CVRMed/MRCAS Conference , pp. 573-582
    • Jaramaz, B.1    Nikou, C.2    Simon, D.3    DiGioia, A.M.4
  • 24
    • 0036523483 scopus 로고    scopus 로고
    • Effect of the display modality on the spatial accuracy of orthopaedic surgery pre-operative planning applications
    • Viceconti, M., Lattanzi, R., Zannoni, C. and Capello, A. 2002, Effect of the display modality on the spatial accuracy of orthopaedic surgery pre-operative planning applications. Medical Informatics and the Internet in Medicine, 1, 21-32, 27.
    • (2002) Medical Informatics and the Internet in Medicine , vol.1 , Issue.27 , pp. 21-32
    • Viceconti, M.1    Lattanzi, R.2    Zannoni, C.3    Capello, A.4
  • 28
    • 84971372881 scopus 로고
    • Marching cubes: A high resolution 3D surface construction algorithm
    • (SIGGRAPH '87 Proceedings), Anaheim, California. 1987
    • Lorensen, W. E. and Cline, H. E., 1987, Marching cubes: a high resolution 3D surface construction algorithm. Proceedings of Computer Graphics (SIGGRAPH '87 Proceedings), Anaheim, California. 1987, pp. 163-169.
    • (1987) Proceedings of Computer Graphics , pp. 63-169
    • Lorensen, W.E.1    Cline, H.E.2
  • 30
    • 0020759032 scopus 로고
    • A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
    • Grood, E. S. and Suntay, W. J., 1983, A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. Journal of Biomechanical Engineering, 2, 136-144, 105.
    • (1983) Journal of Biomechanical Engineering , vol.2 , Issue.105 , pp. 136-144
    • Grood, E.S.1    Suntay, W.J.2
  • 32
    • 0032456049 scopus 로고    scopus 로고
    • Computed-tomography-based computer preoperative planning for total hip arthroplasty
    • Sugano, N., Ohzono, K., Nishii T., Haraguchi, K., Sakai, T. and Ochi, T. 1998, Computed-tomography-based computer preoperative planning for total hip arthroplasty. Computer Aided Surgery, 6, 320-324, 3.
    • (1998) Computer Aided Surgery , vol.6 , Issue.3 , pp. 320-324
    • Sugano, N.1    Ohzono, K.2    Nishii, T.3    Haraguchi, K.4    Sakai, T.5    Ochi, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.