메뉴 건너뛰기




Volumn 27, Issue 2, 2002, Pages 71-83

Hip-Op: An innovative software to plan total hip replacement surgery

Author keywords

Computer aided surgery; Hip prosthesis; Surgical planning; User interface

Indexed keywords

ANATOMICAL VARIATION; ARTICLE; CALCULATION; CLINICAL TRIAL; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER GRAPHICS; COMPUTER INTERFACE; COMPUTER PROGRAM; COMPUTER SIMULATION; HIP RADIOGRAPHY; HUMAN; IMAGE ANALYSIS; IMAGE DISPLAY; INTERNET; MEDICAL PROFESSION; PREOPERATIVE EVALUATION; THREE DIMENSIONAL IMAGING; TOTAL HIP PROSTHESIS; TREATMENT PLANNING;

EID: 84860395913     PISSN: 14639238     EISSN: None     Source Type: Journal    
DOI: 10.1080/14639230210150346     Document Type: Article
Times cited : (51)

References (23)
  • 1
    • 0033861254 scopus 로고    scopus 로고
    • Long-term registration has improved the quality of hip replacement: A review of the Swedish THR Register comparing 160,000 cases
    • HERBERTS, P. and MALCHAU, H., 2000, Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthopaedica Scandinavica, 2, 111-121.
    • (2000) Acta Orthopaedica. Scandinavica , vol.2 , pp. 111-121
    • Herberts, P.1    Malchau, H.2
  • 3
    • 0033767396 scopus 로고    scopus 로고
    • The Danish Hip Arthroplasty Register
    • LUCHT, U., 2000, The Danish Hip Arthroplasty Register. Acta Orthopaedica Scandinavica, 5, 433-439.
    • (2000) Acta Orthopaedica Scandinavica , vol.5 , pp. 433-439
    • Lucht, U.1
  • 4
  • 7
    • 0038008735 scopus 로고    scopus 로고
    • Clinical introduction of the CASPAR system: Problems and initial results
    • Proceedings of 4th Int. Symp. Computer Assisted Orthopaedic Surgery, Davos, Switzerland. Computer Aided Surgery
    • GRUENEIS, C., RICHTER, R. and HENNIG, F. F., 1999, Clinical introduction of the CASPAR system: problems and initial results. Proceedings of 4th Int. Symp. Computer Assisted Orthopaedic Surgery, Davos, Switzerland. Computer Aided Surgery, 4, 160.
    • (1999) , vol.4 , pp. 160
    • Grueneis, C.1    Richter, R.2    Hennig, F.F.3
  • 11
    • 0012074977 scopus 로고    scopus 로고
    • Control of limb length and femoral anteversion in total hip arthroplasty using Optotrak
    • SUGANO, N., SATO, Y., SASAMA, K., NAKAHODO, S. and YODEN, T., 1999, Control of limb length and femoral anteversion in total hip arthroplasty using Optotrak. Computer Aided Surgery, 6, 343.
    • (1999) Computer Aided Surgery , vol.6 , pp. 343
    • Sugano, N.1    Sato, Y.2    Sasama, K.3    Nakahodo, S.4    Yoden, T.5
  • 12
    • 0032178167 scopus 로고    scopus 로고
    • The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment
    • DIGIOIA, A. M., JARAMAZ, B., BLACKWELL, M., SIMON, D. A. and MORGAN, F., 1998, The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clinical Orthopaedics and Related Research, 355, 8-22.
    • (1998) Clinical Orthopaedics and Related Research , vol.355 , pp. 8-22
    • Digioia, A.M.1    Jaramaz, B.2    Blackwell, M.3    Simon, D.A.4    Morgan, F.5
  • 13
    • 0022984363 scopus 로고
    • Preoperative planning of total hip arthroplasty
    • CAPELLO, W. N., 1986, Preoperative planning of total hip arthroplasty. Instructional Course Lectures, 35, 249-257.
    • (1986) Instructional Course Lectures , vol.35 , pp. 249-257
    • Capello, W.N.1
  • 14
    • 0034308101 scopus 로고    scopus 로고
    • Hippin: A semiautomatic computer program for selecting hip prosthesis femoral components
    • BONGINI, D., CARFAGNI, M. and GOVERNI, L., 2000, Hippin: a semiautomatic computer program for selecting hip prosthesis femoral components. Computer Methods and Programs in Biomedicine, 2, 105-115.
    • (2000) Computer Methods and Programs in Biomedicine , vol.2 , pp. 105-115
    • Bongini, D.1    Carfagni, M.2    Governi, L.3
  • 15
    • 0032456049 scopus 로고    scopus 로고
    • Computed-tomography-based computer preoperative planning for total hip arthroplasty
    • SUGANO, N., OHZONO, K., NISHI, T., HARAGUCHI, K., SAKAI, T. and OCHI, T., 1998, Computed-tomography-based computer preoperative planning for total hip arthroplasty. Comput Aided Surgery, 6, 320-324.
    • (1998) Comput Aided Surgery , vol.6 , pp. 320-324
    • Sugano, N.1    Ohzono, K.2    Nishi, T.3    Haraguchi, K.4    Sakai, T.5    Ochi, T.6
  • 16
    • 0033286354 scopus 로고    scopus 로고
    • Computer-assisted planning and simulation of hip operations using virtual three-dimensional models
    • HANDELS, H., EHRHARDT, J., PLOTZ, W. and POPPL, S. J., 1999, Computer-assisted planning and simulation of hip operations using virtual three-dimensional models. Studies in Health Technology and Informatics, 686-689.
    • (1999) Studies in Health Technology and Informatics , pp. 686-689
    • Handels, H.1    Ehrhardt, J.2    Plotz, W.3    Poppl, S.J.4
  • 17
    • 18544398183 scopus 로고    scopus 로고
    • Virtual planning of hip operations and individual adaption of endoprostheses in orthopaedic surgery
    • [In Process Citation]
    • HANDELS, H., EHRHARDT, J., PLOTZ, W. and POPPL, S. J., 2000, Virtual planning of hip operations and individual adaption of endoprostheses in orthopaedic surgery [In Process Citation]. International Journal of Medical Informatics, 58, 21-28.
    • (2000) International Journal of Medical Informatics , vol.58 , pp. 21-28
    • Handels, H.1    Ehrhardt, J.2    Plotz, W.3    Poppl, S.J.4
  • 18
    • 0036523483 scopus 로고    scopus 로고
    • Effect of the display modality on the spatial accuracy of orthopaedic surgery pre-operative planning applications
    • in press
    • VICECONTI, M., LATTANZI, R., ZAUNONI, C. and CAPPELO, A., 2002, Effect of the display modality on the spatial accuracy of orthopaedic surgery pre-operative planning applications. Medical Informatics and the Internet Medicine, in press.
    • (2002) Medical Informatics and the Internet Medicine
    • Viceconti, M.1    Lattanzi, R.2    Zaunoni, C.3    Cappelo, A.4
  • 20
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
    • GRUEN, T. A., MCNEICE, G. M., and AMSTUTZ, H. C., 1979, "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clinical Orthopaedics and Related Research, 141, 17-27.
    • (1979) Clinical Orthopaedics and Related Research , vol.141 , pp. 17-27
    • Gruen, T.A.1    Mcneice, G.M.2    Amstutz, H.C.3
  • 21
    • 0003762561 scopus 로고    scopus 로고
    • 2nd edition (Upper Saddle River, New Jersey: Prentice Hall)
    • WELCH, B. B., 1997, Practical programming in Tcl and Tk, 2nd edition (Upper Saddle River, New Jersey: Prentice Hall).
    • (1997) Practical Programming in Tcl and Tk
    • Welch, B.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.