Volumn 37, Issue 2, 1997, Pages 465-468

Effect of beam blocking on linac head scatter factors

Author keywords

Blocked field; Head scatter; Multileaf collimator

Indexed keywords

ARTICLE; BEAM THERAPY; COLLIMATOR; GEOMETRY; HEAD; JAW; LINEAR ACCELERATOR; MANDIBLE; MAXILLA; PHOTON; PRIORITY JOURNAL; RADIATION FIELD; RADIATION SCATTERING; RADIATION SHIELD;

EID: 0030936245     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0360-3016(96)00495-6     Document Type: Article
Times cited : (7)

References (11)
  • 1
    • 0027966969 scopus 로고
    • Analytic modeling of photon scatter from flattening filters in photon therapy beams
    • Ahnesjö, A. Analytic modeling of photon scatter from flattening filters in photon therapy beams. Med. Phys. 21:1227-1235; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1227-1235
    • Ahnesjö, A.1
  • 2
    • 0028129772 scopus 로고
    • A monte carlo study of accelerator head scatter
    • Chaney, E. L.; Cullip, T. J.; Gabriel, T. A. A Monte Carlo study of accelerator head scatter. Med. Phys. 21:1383-1390; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1383-1390
    • Chaney, E.L.1    Cullip, T.J.2    Gabriel, T.A.3
  • 3
    • 0026472120 scopus 로고
    • On the field-size dependence of relative output from a linear accelerator
    • Dunscombe, P. B.; Nieminen, J. M. On the field-size dependence of relative output from a linear accelerator. Med. Phys. 19:1441-1444; 1992.
    • (1992) Med. Phys. , vol.19 , pp. 1441-1444
    • Dunscombe, P.B.1    Nieminen, J.M.2
  • 4
    • 0027752810 scopus 로고
    • X-ray source of medical linear accelerators: Focal and extra-focal radiation
    • Jaffray, D. A.; Battista. J. J.; Fenster, A.; Munro, P. X-ray source of medical linear accelerators: Focal and extra-focal radiation. Med. Phys. 20:1417-1427; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 1417-1427
    • Jaffray, D.A.1    Battista, J.J.2    Fenster, A.3    Munro, P.4
  • 5
    • 0018858258 scopus 로고
    • Revision of tissue-maximum ratio and scatter-maximum ratio concepts for cobalt 60 and higher energy x-ray beams
    • Khan, F. M.; Sewchand, W.; Lee, J.; Williamson, J. F. Revision of tissue-maximum ratio and scatter-maximum ratio concepts for cobalt 60 and higher energy x-ray beams. Med. Phys. 7:230-237; 1980.
    • (1980) Med. Phys. , vol.7 , pp. 230-237
    • Khan, F.M.1    Sewchand, W.2    Lee, J.3    Williamson, J.F.4
  • 6
    • 0004666807 scopus 로고
    • Accuracy of dose calculations of the philips treatment planning system OSS for blocked fields
    • Bruinvis, I.; van der Giessen, P.; van Kleffens, H.; Wittkamper, F., eds. Amsterdam, Netherlands
    • Sauer, O.; Nowak, G.; Richter, J. Accuracy of dose calculations of the Philips Treatment Planning System OSS for blocked fields. In: Bruinvis, I.; van der Giessen, P.; van Kleffens, H.; Wittkamper, F., eds. Proceedings of the 9th International Conference on the Use of Computers in Radiation Therapy. Amsterdam, Netherlands; 1987:57-60.
    • (1987) Proceedings of the 9th International Conference on the Use of Computers in Radiation Therapy , pp. 57-60
    • Sauer, O.1    Nowak, G.2    Richter, J.3
  • 7
    • 0027992838 scopus 로고
    • Head-scatter factors in blocked photon fields
    • Tatcher, M.; Bjärngard, B. E. Head-scatter factors in blocked photon fields. Radiother. Oncol. 33:64-67; 1994.
    • (1994) Radiother. Oncol. , vol.33 , pp. 64-67
    • Tatcher, M.1    Bjärngard, B.E.2
  • 8
    • 0026637112 scopus 로고
    • Influence of shielding blocks on the output of photon beams as a function of energy and type of treatment unit
    • van Dam, J.; Bridier, A.; Lasselin, C.; Blanckaert, N.; Dutreix, A. Influence of shielding blocks on the output of photon beams as a function of energy and type of treatment unit. Radiother. Oncol. 24:55-59; 1992.
    • (1992) Radiother. Oncol. , vol.24 , pp. 55-59
    • Van Dam, J.1    Bridier, A.2    Lasselin, C.3    Blanckaert, N.4    Dutreix, A.5
  • 9
    • 0029900443 scopus 로고    scopus 로고
    • Analytical representation of head-scatter factors for shaped photon beams using a two-component x-ray source model
    • Yu, M. K.; Sloboda, R. S. Analytical representation of head-scatter factors for shaped photon beams using a two-component x-ray source model. Med. Phys. 23:973-984; 1996.
    • (1996) Med. Phys. , vol.23 , pp. 973-984
    • Yu, M.K.1    Sloboda, R.S.2
  • 10
    • 0029785031 scopus 로고    scopus 로고
    • Measurement of photon beam backscatter from collimators to the beam monitor chamber using target current pulse counting and telescope techniques
    • Yu, M. K.; Sloboda, R. S.; Mansour, F. Measurement of photon beam backscatter from collimators to the beam monitor chamber using target current pulse counting and telescope techniques. Phys. Med. Biol. 41:1107-1117; 1996.
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1107-1117
    • Yu, M.K.1    Sloboda, R.S.2    Mansour, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.