메뉴 건너뛰기




Volumn 34, Issue 1, 2003, Pages 151-160

Fabrication of piezoelectric biochips with self-assembled alkanethiol layer and hydrocoating

Author keywords

Alkanethiols; Flow injection assay; Human immunoglobulin G; Hydrocoating; Piezoelectric biochip; Protein A; Self assembled layer

Indexed keywords

ADSORPTION; ATOMIC FORCE MICROSCOPY; CONTACT ANGLE; CRYSTAL STRUCTURE; ELECTROCHEMICAL ELECTRODES; ELECTRON MICROSCOPES; MORPHOLOGY; PROTEINS; SELF ASSEMBLY;

EID: 0038066747     PISSN: 03681653     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (26)
  • 1
    • 0000363707 scopus 로고
    • Atomic scale imaging kof alkanethiolate. Monolayers at gold surfaces with atomic force microscopy
    • Alves, C. A., F, L. Smith and M. D. Porter. "Atomic Scale Imaging of Alkanethiolate Monolayers at Gold Surfaces with Atomic Force Microscopy," J. Am. Chem. Soc., 114, 1222 (1992).
    • (1992) J. Am. Chem. Soc. , vol.114 , pp. 1222
    • Alves, C.A.1    Smith, F.L.2    Porter, M.D.3
  • 2
    • 1942481178 scopus 로고
    • Whitesides formation of monolayer films by the spontaneous assembly of organic thiols from solution onto gold
    • Bain, C. D., E. B. Troughton, Y.-T. Tao, J. Evall, G. M. Whitesides and R. G. Nuzzo, "Formation of Monolayer Films by the Spontaneous Assembly of Organic Thiols from Solution onto Gold," J. Am. Chem., Soc., 111, 321 (1989).
    • (1989) J. Am. Chem., Soc. , vol.111 , pp. 321
    • Bain, C.D.1    Troughton, E.B.2    Tao, Y.-T.3    Evall, J.4    Winteside, Y.-Y.5    Nuzzo, R.G.6
  • 3
    • 0014969185 scopus 로고
    • Reaction of carbodimides with protein sulfhydryl groups
    • Carraway, K. L. and R. B. Triplett, "Reaction of Carbodimides with Protein Sulfhydryl Groups," Biochim. Biophys. Acta, 200, 564 (1970)
    • (1970) Biochim. Biophys. Acta , vol.200 , pp. 564
    • Carraway, K.L.1    Triplett, R.B.2
  • 4
    • 0001451622 scopus 로고
    • Surface chemical activation of quartz crystal microbalance gold electrodes - Analysis by frequency changes, contact angle measurements and grazing Angle FTIR
    • Geddes, N. J., E. M. Paschinger, D. N. Furlong, F. Caruso, C. L. Hoffmann and J. F. Rabolt, "Surface Chemical Activation of Quartz Crystal Microbalance Gold Electrodes - Analysis by Frequency Changes, Contact Angle Measurements and Grazing Angle FTIR," Thin Solid Films, 260, 192 (1995).
    • (1995) Thin Solid Films , vol.260 , pp. 192
    • Geddes, N.J.1    Paschinger, E.M.2    Furlong, D.N.3    Caruso, F.4    Hoffmann, C.L.5    Rabolt, J.F.6
  • 5
    • 0028907140 scopus 로고
    • Hydrocoating: A new method for coupling biomolecules to solid phases
    • Gregorius, K., S. Mouritsen and H. I. Elsner, "Hydrocoating: a New Method for Coupling Biomolecules to Solid Phases," J. Immunol. Methods, 181, 65 (1995).
    • (1995) J. Immunol. Methods , vol.181 , pp. 65
    • Gregorius, K.1    Mouritsen, S.2    Elsner, H.I.3
  • 6
    • 0029542233 scopus 로고
    • Cellulose as a new matrix for one-step immobilized antibodies and application in high specific immunosensors
    • Hartmann, A., D. Bock, M. Schulze, H. Tebbe, G. Wegner and S. Seeger, "Cellulose as a New Matrix for One-Step Immobilized Antibodies and Application in High Specific Immunosensors," Transducers '95. Eurosensors IX, p. 505 (1995).
    • (1995) Transducers '95. Eurosensors IX , pp. 505
    • Hartmann, A.1    Bock, D.2    Schulze, M.3    Tebbe, H.4    Wegner, G.5    Seeger, S.6
  • 7
    • 0017556722 scopus 로고
    • Application of the piezoelectric crystal detector in analytical chemistry
    • Hlavay, J. and G. G. Guilbault, "Application of the Piezoelectric Crystal Detector in Analytical Chemistry," Anal. Chem., 49, 1890 (1977).
    • (1977) Anal. Chem. , vol.49 , pp. 1890
    • Hlavay, J.1    Guilbault, G.G.2
  • 8
    • 0039907272 scopus 로고    scopus 로고
    • Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-Dichlorophe-noxyacetic acid
    • Horácek, J. and P. Skládal, "Improved Direct Piezoelectric Biosensors Operating in Liquid Solution for the Competitive Label-Free Immunoassay of 2,4-Dichlorophe-noxyacetic Acid," Anal. Chim. Acta, 347, 43 (1997).
    • (1997) Anal. Chim. Acta , vol.347 , pp. 43
    • Horácek, J.1    Skládal, P.2
  • 10
    • 0027476562 scopus 로고
    • Development of a piezoelectric immunosensor for the detection of human erythrocytes
    • König, B. and M. Grätzel, "Development of a Piezoelectric Immunosensor for the Detection of Human Erythrocytes," Anal. Chim. Acta, 276, 329 (1993).
    • (1993) Anal. Chim. Acta , vol.276 , pp. 329
    • König, B.1    Grätzel, M.2
  • 11
    • 0028372590 scopus 로고
    • A novel immunosensor for herpes viruses
    • König, B. and M. Grätzel, "A Novel Immunosensor for Herpes Viruses," Anal. Chem., 66, 341 (1994).
    • (1994) Anal. Chem. , vol.66 , pp. 341
    • König, B.1    Grätzel, M.2
  • 12
    • 0012749274 scopus 로고    scopus 로고
    • Measurement of dynamic/advancing/receding contact angle by video-enhanced sessile drop tensiometry
    • Lin, S.-Y., H.-C. Chang, L.-W. Lin and P.-Y. Huang, "Measurement of Dynamic/Advancing/Receding Contact Angle by Video-Enhanced Sessile Drop Tensiometry," Rev. Sci. Instrum., 67, 2852 (1996).
    • (1996) Rev. Sci. Instrum. , vol.67 , pp. 2852
    • Lin, S.-Y.1    Chang, H.-C.2    Lin, L.-W.3    Huang, P.-Y.4
  • 13
    • 37049079283 scopus 로고
    • A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands
    • Löfas, S. and B. Johnson, "A Novel Hydrogel Matrix on Gold Surfaces in Surface Plasmon Resonance Sensors for Fast and Efficient Covalent Immobilization of Ligands," J. Chem. Soc., Chem. Commun., 19, 1526 (1990).
    • (1990) J. Chem. Soc., Chem. Commun. , vol.19 , pp. 1526
    • Löfas, S.1    Johnson, B.2
  • 14
    • 0033969873 scopus 로고    scopus 로고
    • A resuable and specific protein a-coated piezoelectric biosensor for flow injection immunoassay
    • Lu, H.-C., H.-M. Chen, Y.-S. Lin and J.-W. Lin "A Resuable and Specific Protein A-Coated Piezoelectric Biosensor for Flow Injection Immunoassay," Biotech. Prog., 16, 116 (2000).
    • (2000) Biotech. Prog. , vol.16 , pp. 116
    • Lu, H.-C.1    Chen, H.-M.2    Lin, Y.-S.3    Lin, J.-W.4
  • 15
    • 0003875705 scopus 로고
    • Analytical applications of piezoelectric crystal biosensors
    • Chap. 6, L. J. Blum and P. R. Coulet, eds., Marcel Dekker, Inc., New York, U.S.A
    • Luong, J. H. T. and G. G. Guilbault, "Analytical Applications of Piezoelectric Crystal Biosensors," Biosensor Principles and Applications, Chap. 6, L. J. Blum and P. R. Coulet, eds., Marcel Dekker, Inc., New York, U.S.A. (1991).
    • (1991) Biosensor Principles and Applications
    • Luong, J.H.T.1    Guilbault, G.G.2
  • 16
    • 0034506315 scopus 로고    scopus 로고
    • Fabrication and application of hydrogel stampers for physisorptive microcontact printing
    • Martin, B. D., S. L., Brandow, W. J. Dressick and T. L. Schull, "Fabrication and Application of Hydrogel Stampers for Physisorptive Microcontact Printing," Langmuir, 16, 9944 (2000).
    • (2000) Langmuir , vol.16 , pp. 9944
    • Martin, B.D.1    Brandow, S.L.2    Dressick, W.J.3    Schull, T.L.4
  • 18
    • 33845281250 scopus 로고
    • Fundamental studies of the chemisorption of organosulfur compounds on au (111). Implications for molecular self-assembly on gold surfaces
    • Nuzzo, R. G., B. R. Zegarski and L. H. Dubois, "Fundamental Studies of the Chemisorption of Organosulfur Compounds on Au (111). Implications for Molecular Self-Assembly on Gold Surfaces," J. Am. Chem. Soc., 109, 733 (1987).
    • (1987) J. Am. Chem. Soc. , vol.109 , pp. 733
    • Nuzzo, R.G.1    Zegarski, B.R.2    Dubois, L.H.3
  • 19
    • 0028695972 scopus 로고
    • Use of protein a as an immunological reagent and its application using flow injection, a review
    • Palmer, D. A., M. T. French and J. N. Miller, "Use of Protein A as an Immunological Reagent and its Application Using Flow Injection, a Review," The Analyst, 119, 2769 (1994).
    • (1994) The Analyst , vol.119 , pp. 2769
    • Palmer, D.A.1    French, M.T.2    Miller, J.N.3
  • 22
    • 0030761002 scopus 로고    scopus 로고
    • Quartz crystal microbalances for quantitative biosensing and characterizing protein multilayers
    • Rickert, J., A. Brecht and W. Göpel, "Quartz Crystal Microbalances for Quantitative Biosensing and Characterizing Protein Multilayers," Biosens. Bioelectron., 12, 567 (1997).
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 567
    • Rickert, J.1    Brecht, A.2    Göpel, W.3
  • 23
    • 84951279351 scopus 로고
    • Use of quartz vibrator for weighing thin films on a microbalance
    • Sauerbrey, G. Z., "Use of Quartz Vibrator for Weighing Thin Films on a Microbalance," Z. Phys., 155, 206 (1959).
    • (1959) Z. Phys. , vol.155 , pp. 206
    • Sauerbrey, G.Z.1
  • 24
    • 0029034904 scopus 로고
    • Enzyme or protein immobilization techniques for applications in biosensor design
    • Scouten, W. H., J. H. T. Luong and R. S. Brown, "Enzyme or Protein Immobilization Techniques for Applications in Biosensor Design," Trends Biotechnol., 13, 178 (1995).
    • (1995) Trends Biotechnol. , vol.13 , pp. 178
    • Scouten, W.H.1    Luong, J.H.T.2    Brown, R.S.3
  • 25
    • 0343010447 scopus 로고    scopus 로고
    • Construction and characterization of the direct piezoelectric immunosensor for atrazine operating in solution
    • Steegborn, C. and P. Skládal, "Construction and Characterization of the Direct Piezoelectric Immunosensor for Atrazine Operating in Solution," Biosens. Bioelectron., 12, 19 (1997).
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 19
    • Steegborn, C.1    Skládal, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.