Analytical models for multi-slice helical CT performance parameters

Author keywords

Helical CT; Multi slice computed tomography; Noise ratio; Slice sensitivity profile

Indexed keywords

CLOSED-FORM EXPRESSION; DETECTOR CONFIGURATION; HELICAL CT; MULTISLICE COMPUTED TOMOGRAPHY; NOISE RATIO; RECONSTRUCTION ALGORITHMS; SLICE-SENSITIVITY PROFILES; TECHNOLOGICAL ADVANCEMENT;

EID: 0037320045     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1533750     Document Type: Article
Times cited : (39)

References (18)
  • 4
    • 0031956821 scopus 로고    scopus 로고
    • Algorithm for image reconstruction in multi-slice helical CT
    • K. Taguchi and H. Aradate, "Algorithm for image reconstruction in multi-slice helical CT," Med. Phys. 25, 1521-1532 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 1521-1532
    • Taguchi, K.1    Aradate, H.2
  • 5
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • H. Hu, "Multi-slice helical CT: scan and reconstruction," Med. Phys. 26, 1-18 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1-18
    • Hu, H.1
  • 6
    • 0034977516 scopus 로고    scopus 로고
    • Advanced single-slice rebinning for tilted spiral cone-beam CT
    • M. Kacheiriess, T. Fuchs, S. Schaller, and W. A. Kalender, "Advanced single-slice rebinning for tilted spiral cone-beam CT," Med. Phys. 28, 1033-1041 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 1033-1041
    • Kacheiriess, M.1    Fuchs, T.2    Schaller, S.3    Kalender, W.A.4
  • 9
    • 0000543111 scopus 로고    scopus 로고
    • Optimization of solid state detector design for 0.5s multislice CT
    • J. Hsieh, E. Gurmen, and K. F. King, "Optimization of solid state detector design for 0.5s multislice CT," Radiology 213, 318 (1999).
    • (1999) Radiology , vol.213 , pp. 318
    • Hsieh, J.1    Gurmen, E.2    King, K.F.3
  • 10
    • 0032718470 scopus 로고    scopus 로고
    • Performance Evaluation of a Multislice CT System
    • C. H. McCollough and F. E. Zink, "Performance Evaluation of a Multislice CT System," Med. Phys. 26, 2223-2230 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2223-2230
    • McCollough, C.H.1    Zink, F.E.2
  • 11
    • 0000487147 scopus 로고    scopus 로고
    • Experimental evaluation of image quality of four-slice spiral CT
    • T. O. Fuchs, J. U. Krause, H. Wolf, and W. A. Kalender, "Experimental evaluation of image quality of four-slice spiral CT," Radiology 213, 317 (1999).
    • (1999) Radiology , vol.213 , pp. 317
    • Fuchs, T.O.1    Krause, J.U.2    Wolf, H.3    Kalender, W.A.4
  • 12
    • 0032913761 scopus 로고    scopus 로고
    • Experimental determination of section sensitivity profiles and image noise in electron beam computed tomography
    • C. H. McCollough, K. M. Kanal, N. Lannutti, and K. J. Ryan, "Experimental determination of section sensitivity profiles and image noise in electron beam computed tomography," Med. Phys. 26, 287-295 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 287-295
    • McCollough, C.H.1    Kanal, K.M.2    Lannutti, N.3    Ryan, K.J.4
  • 13
    • 0035053112 scopus 로고    scopus 로고
    • Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography
    • J. Hsieh, "Investigation of the slice sensitivity profile for step-and-shoot mode multi-slice computed tomography," Med. Phys. 28, 491-500 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 491-500
    • Hsieh, J.1
  • 14
    • 0002335619 scopus 로고
    • Principles and performance of spiral CT
    • edited by L. W. Goldman and J. B. Fowlkes (Advanced Medical Publishing, Madison, WI)
    • W. A. Kalender, "Principles and performance of spiral CT," in Medical CT and Ultrasound: Current Technology and Applications, edited by L. W. Goldman and J. B. Fowlkes (Advanced Medical Publishing, Madison, WI, 1995), pp. 379-410.
    • (1995) Medical CT and Ultrasound: Current Technology and Applications , pp. 379-410
    • Kalender, W.A.1
  • 15
    • 0343920761 scopus 로고    scopus 로고
    • Spatially varying longitudinal aliasing and resolution in spiral computed tomography
    • S. Y. Yen, G. D. Rubin, and S. Napel, "Spatially varying longitudinal aliasing and resolution in spiral computed tomography," Med. Phys. 26, 2617-2625 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2617-2625
    • Yen, S.Y.1    Rubin, G.D.2    Napel, S.3
  • 16
    • 0037036611 scopus 로고    scopus 로고
    • Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)
    • P. J. La Riviere and X. Pan, "Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)," Phys. Med. Biol. 47, 2797-2810 (2002).
    • (2002) Phys. Med. Biol. , vol.47 , pp. 2797-2810
    • La Riviere, P.J.1    Pan, X.2
  • 17
    • 0030866638 scopus 로고    scopus 로고
    • Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts
    • J. Hsieh, "Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts," Med. Phys. 24, 1375-1384 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1375-1384
    • Hsieh, J.1
  • 18
    • 0017438802 scopus 로고
    • Development of a phantom for evaluation and assurance of image quality in CT scanning
    • D. J. Goodenough, K. E. Weaver, and D. O. Davis, "Development of a phantom for evaluation and assurance of image quality in CT scanning," Opt. Eng. 16, 52-65 (1977).
    • (1977) Opt. Eng. , vol.16 , pp. 52-65
    • Goodenough, D.J.1    Weaver, K.E.2    Davis, D.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.