Volumn 26, Issue 2, 1999, Pages 287-295

Experimental determination of section sensitivity profiles and image noise in electron beam computed tomography

Author keywords

CT image quality; CT physics; Electron beam CT; Spiral CT technology

Indexed keywords

ELECTRON BEAM COMPUTED TOMOGRAPHY; ELECTRON BEAMS; FULL WIDTH AT HALF MAXIMUM; PHANTOMS;

EID: 0032913761     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598515     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0141611935 scopus 로고
    • Transmission computed tomography
    • edited by T. H. Newton and D. G. Potts Mosby, St. Louis
    • D. P. Boyd, "Transmission computed tomography," in Radiology of the Skull and Brain: Technical Aspects of Computed Tomography, edited by T. H. Newton and D. G. Potts (Mosby, St. Louis, 1981), Vol. 5, pp. 4357-4371.
    • (1981) Radiology of the Skull and Brain: Technical Aspects of Computed Tomography , vol.5 , pp. 4357-4371
    • Boyd, D.P.1
  • 2
    • 0013594154 scopus 로고
    • Computerized transmission tomography of the heart using scanning electron beams
    • edited by C. B. Higgins Futura, Mount Kisco, New York
    • D. P. Boyd, "Computerized transmission tomography of the heart using scanning electron beams," in CT of the Heart and the Great Vessels: Experimental Evaluation and Clinical Application, edited by C. B. Higgins (Futura, Mount Kisco, New York, 1983), pp. 45-60.
    • (1983) CT of the Heart and the Great Vessels: Experimental Evaluation and Clinical Application , pp. 45-60
    • Boyd, D.P.1
  • 4
    • 0028271883 scopus 로고
    • The technical design and performance of ultrafast computed tomography
    • C. H. McCollough and R. L. Morin, "The technical design and performance of ultrafast computed tomography," Radiol. Clin. North Am. 32, 521-536 (1994).
    • (1994) Radiol. Clin. North Am. , vol.32 , pp. 521-536
    • McCollough, C.H.1    Morin, R.L.2
  • 5
    • 0344321908 scopus 로고
    • Principles and performance of electron beam CT
    • edited by L. W. Goldman and J. B. Fowlkes Advanced Medical Publishing, Madison, Wisconsin
    • C. H. McCollough, "Principles and performance of electron beam CT," in Medical CT and Ultrasound: Current Technology and Applications, edited by L. W. Goldman and J. B. Fowlkes (Advanced Medical Publishing, Madison, Wisconsin, 1995), pp. 411-436.
    • (1995) Medical CT and Ultrasound: Current Technology and Applications , pp. 411-436
    • McCollough, C.H.1
  • 6
    • 0001124733 scopus 로고
    • Quality control and acceptance testing of CT systems
    • edited by L. W. Goldman and J. B. Fowlkes Advanced Medical Publishing, Madison, Wisconsin
    • C. H. McCollough and F. E. Zink, "Quality control and acceptance testing of CT systems," in Medical CT and Ultrasound: Current Technology and Applications, edited by L. W. Goldman and J. B. Fowlkes (Advanced Medical Publishing, Madison, Wisconsin, 1995), pp. 437-465.
    • (1995) Medical CT and Ultrasound: Current Technology and Applications , pp. 437-465
    • McCollough, C.H.1    Zink, F.E.2
  • 7
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • A. Polacin, W. A. Kalender, and G. Marchal, "Evaluation of section sensitivity profiles and image noise in spiral CT," Radiology 185, 29-35 (1992).
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 9
    • 0023184763 scopus 로고
    • Section thickness and contiguity phantom for MR imaging
    • J. E. Gray and J. P. Felmlee, "Section thickness and contiguity phantom for MR imaging." Radiology 164, 193-197 (1987).
    • (1987) Radiology , vol.164 , pp. 193-197
    • Gray, J.E.1    Felmlee, J.P.2
  • 10
    • 0028258284 scopus 로고
    • Longitudinal resolution in volumetric x-ray computerized tomography: Analytical comparison between conventional and helical computerized tomography
    • G. Wang and M. W. Vannier, "Longitudinal resolution in volumetric x-ray computerized tomography: Analytical comparison between conventional and helical computerized tomography," Med. Phys. 21, 429-433 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 429-433
    • Wang, G.1    Vannier, M.W.2
  • 11
    • 0027144470 scopus 로고
    • Helical CT image noise: Analytical results
    • G. Wang and M. W. Vannier, "Helical CT image noise: Analytical results," Med. Phys. 20, 1635-1640 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1635-1640
    • Wang, G.1    Vannier, M.W.2
  • 12
    • 0028049871 scopus 로고
    • Spatial variation of section sensitivity profile in helical computed tomography
    • G. Wang and M. W. Vannier, "Spatial variation of section sensitivity profile in helical computed tomography," Med. Phys. 21, 1491-1497 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1491-1497
    • Wang, G.1    Vannier, M.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.