메뉴 건너뛰기




Volumn 26, Issue 12, 1999, Pages 2617-2625

Spatially varying longitudinal aliasing and resolution in spiral computed tomography

Author keywords

Longitudinal aliasing; Longitudinal resolution; Sampling; Spiral CT

Indexed keywords

ADDITIVE NOISE; PHANTOMS; SAMPLING;

EID: 0343920761     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598801     Document Type: Article
Times cited : (25)

References (15)
  • 1
    • 0029612812 scopus 로고
    • Thin-section three-dimensional spiral CT: Is isotropic imaging possible?
    • W. A. Kalender, "Thin-section three-dimensional spiral CT: Is isotropic imaging possible?" Radiology 197, 578-580 (1995).
    • (1995) Radiology , vol.197 , pp. 578-580
    • Kalender, W.A.1
  • 2
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • C. R. Crawford and K. F. King, "Computed tomography scanning with simultaneous patient translation," Med. Phys. 17, 967-982 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 3
    • 0028258284 scopus 로고
    • Longitudinal resolution in volumetric x-ray computerized tomography - Analytical comparison between conventional and helical computerized tomography
    • G. Wang and M. W. Vannier, "Longitudinal resolution in volumetric x-ray computerized tomography - Analytical comparison between conventional and helical computerized tomography," Med. Phys. 21, 429-433 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 429-433
    • Wang, G.1    Vannier, M.W.2
  • 4
    • 0028264008 scopus 로고
    • Theoretical FWTM values in helical CT
    • G. Wang, J. A. Brink, and M. W. Vannier, "Theoretical FWTM values in helical CT," Med. Phys. 21, 753-754 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 753-754
    • Wang, G.1    Brink, J.A.2    Vannier, M.W.3
  • 5
    • 0026712389 scopus 로고
    • Evaluation of section sensitivity profiles and image noise in spiral CT
    • A. Polacin, W. A. Kalender, and G. Marchal, "Evaluation of section sensitivity profiles and image noise in spiral CT," Radiology 185, 29-35 (1992).
    • (1992) Radiology , vol.185 , pp. 29-35
    • Polacin, A.1    Kalender, W.A.2    Marchal, G.3
  • 7
    • 0028049871 scopus 로고
    • Spatial variation of section sensitivity profile in spiral computed tomography
    • G. Wang and M. W. Vannier, "Spatial variation of section sensitivity profile in spiral computed tomography," Med. Phys. 21, 1491-1497 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1491-1497
    • Wang, G.1    Vannier, M.W.2
  • 8
    • 0343433446 scopus 로고    scopus 로고
    • Assessment of section profile and clinical images in helical CT with pitch values of 0.5-3.0 by using 180° linear extrapolation and segmented reconstruction
    • G. D. Rubin, S. Napel, H. Ringl, and T. Brosnan, "Assessment of section profile and clinical images in helical CT with pitch values of 0.5-3.0 by using 180° linear extrapolation and segmented reconstruction," Radiology 201, 188 (1996).
    • (1996) Radiology , vol.201 , pp. 188
    • Rubin, G.D.1    Napel, S.2    Ringl, H.3    Brosnan, T.4
  • 10
    • 0018411844 scopus 로고
    • Theoretical resolution of computed tomography systems
    • G. H. Glover and R Eisner, "Theoretical resolution of computed tomography systems," J. Comput. Assist. Tomogr. 3, 85-91 (1979).
    • (1979) J. Comput. Assist. Tomogr. , vol.3 , pp. 85-91
    • Glover, G.H.1    Eisner, R.2
  • 12
    • 0027955501 scopus 로고
    • Measurement of slice sensitivity profiles in spiral CT
    • A. Polacin, W. A. Kalender, J. Brink, and M. W. Vannier, "Measurement of slice sensitivity profiles in spiral CT," Med. Phys. 21, 133-140 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 133-140
    • Polacin, A.1    Kalender, W.A.2    Brink, J.3    Vannier, M.W.4
  • 13
    • 0004258826 scopus 로고
    • edited by L. M. Biberman Plenum, New York
    • Perception of Displayed Information, edited by L. M. Biberman (Plenum, New York, 1973).
    • (1973) Perception of Displayed Information
  • 14
    • 0027883177 scopus 로고
    • Aliasing as noise: A quantitative and qualitative assessment
    • S. K. Park and R. Hazra, "Aliasing as noise: A quantitative and qualitative assessment," J. Opt. Soc. Am. 1969, 54-65 (1993).
    • (1993) J. Opt. Soc. Am. , vol.1969 , pp. 54-65
    • Park, S.K.1    Hazra, R.2
  • 15
    • 0028298099 scopus 로고
    • A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions
    • W. A. Kalender, A. Polacin, and C. Süss, "A comparison of conventional and spiral CT: An experimental study on the detection of spherical lesions," J. Comput. Assist. Tomogr. 18, 167-176 (1994).
    • (1994) J. Comput. Assist. Tomogr. , vol.18 , pp. 167-176
    • Kalender, W.A.1    Polacin, A.2    Süss, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.