메뉴 건너뛰기




Volumn 81, Issue 2-3, 2002, Pages 369-376

Bi-enzymatic and capillary electrophoretic analysis of non-fluorescent compounds in microfluidic devices - Determination of xanthine

Author keywords

Bi enzyme system; Chemiluminescence; Indirect LIF detection; Microfluidic devices; Xanthine

Indexed keywords

CAPILLARY ELECTROPHORESIS (CE); LASER-INDUCED FLUORESCENCE (LIF); MICROFLUIDIC DEVICES;

EID: 0037021782     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(01)00963-7     Document Type: Article
Times cited : (64)

References (44)
  • 10
    • 0035866639 scopus 로고    scopus 로고
    • Microseparation chips for performing multienzymatic dehydrogenase/oxidase assays: Simultaneous electrochemical measurement of ethanol and glucose
    • (2001) Anal. Chem. , vol.73 , pp. 1296-1300
    • Wang, J.1    Chatrathi, M.P.2    Tian, B.3
  • 11
    • 0031752710 scopus 로고    scopus 로고
    • Chemiluminescence detection in integrated post-separation reactors for microchip-based capillary electrophoresis and affinity electrophoresis
    • (1998) Electrophoresis , vol.19 , pp. 2301-2307
    • Mangru, S.D.1    Harrison, D.J.2
  • 23
    • 0032529924 scopus 로고    scopus 로고
    • Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry
    • (1998) Anal. Chem. , vol.70 , pp. 3721-3727
    • Figeys, D.1    Aebersold, R.2
  • 27
    • 0024253869 scopus 로고
    • Optimization of sensitivity and separation in capillary zone electrophoresis with indirect fluorescence detection
    • (1988) Anal. Chem. , vol.60 , pp. 2642-2646
    • Kuhr, W.G.1    Yeung, S.Y.2
  • 29
    • 0030728198 scopus 로고    scopus 로고
    • System peaks in capillary zone electrophoresis 3. Practical rules for predicting the existence of system peaks in capillary zone electrophoresis of anions using indirect spectrophotometric detection
    • (1997) Electrophoresis , vol.18 , pp. 1998-2007
    • Macka, M.1    Haddad, P.R.2    Gebauer, P.3    Bocek, P.4
  • 32
    • 0000034324 scopus 로고    scopus 로고
    • Development of a hypoxanthine biosensor based on immobilized xanthine oxidase chemically modified electrode
    • (1997) Electroanalysis , vol.9 , pp. 372-377
    • Hu, S.1    Liu, C.-C.2
  • 36
    • 0029948194 scopus 로고    scopus 로고
    • Simultaneous determination of adenosine, inosine, hypoxanthine, xanthine and uric acid in microdialysis samples using microbore column high-performance liquid chromatography with a diode array detector
    • (1996) Anal. Biochem. , vol.238 , pp. 34-39
    • Mei, D.A.1    Gross, G.J.2    Nithipatikom, K.3
  • 41
    • 0000004795 scopus 로고
    • Micromachining of capillary electrophoresis injectors and separators on glass chips and evaluation of flow at capillary intersections
    • (1994) Anal. Chem. , vol.66 , pp. 177-184
    • Fan, Z.H.1    Harrison, D.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.