1
-
-
84987589831
-
Effect of interference on amperometric glucose biosensors with cellulose acetate membranes
-
R. Vaidya, E. Wilkins, Effect of interference on amperometric glucose biosensors with cellulose acetate membranes, Electroanalysis 6 (1994) 677-682.
-
(1994)
Electroanalysis
, vol.6
, pp. 677-682
-
-
Vaidya, R.1
Wilkins, E.2
-
3
-
-
0029005946
-
® polymer and 1,1′-dimethylferricinium mediator
-
® polymer and 1,1′-dimethylferricinium mediator, Anal. Chim. Acta 310 (1995) 419-427.
-
(1995)
Anal. Chim. Acta
, vol.310
, pp. 419-427
-
-
Brown, R.S.1
Luong, J.H.T.2
-
5
-
-
0024095481
-
Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood
-
D.J Harrison, R.F.B. Turner, H.P. Baltes, Characterization of perfluorosulfonic acid polymer coated enzyme electrodes and a miniaturized integrated potentiostat for glucose analysis in whole blood, Anal. Chem. 60 (1988) 2002-2007.
-
(1988)
Anal. Chem.
, vol.60
, pp. 2002-2007
-
-
Harrison, D.J.1
Turner, R.F.B.2
Baltes, H.P.3
-
6
-
-
0026466109
-
A facile method of regulating the dynamic range of 1-lactate sensor based on polymer coating
-
J. Anzai, N. Inomata, T. Osa, M. Morita, K. Maehara, A facile method of regulating the dynamic range of 1-lactate sensor based on polymer coating, Chem. Pharm. Bull. 40 (1992) 2897-2899.
-
(1992)
Chem. Pharm. Bull.
, vol.40
, pp. 2897-2899
-
-
Anzai, J.1
Inomata, N.2
Osa, T.3
Morita, M.4
Maehara, K.5
-
7
-
-
0028418786
-
Elimination of the acetaminophen interference in an implantable glucose sensor
-
Y. Zhang, Y. Hu, G.S. Wilson, D. Moatti-Sirat, V. Poitout, G. Reach, Elimination of the acetaminophen interference in an implantable glucose sensor, Anal. Chem. 66 (1994) 1183-1188.
-
(1994)
Anal. Chem.
, vol.66
, pp. 1183-1188
-
-
Zhang, Y.1
Hu, Y.2
Wilson, G.S.3
Moatti-Sirat, D.4
Poitout, V.5
Reach, G.6
-
8
-
-
0029117045
-
Development of a needle-type biosensor for intravascular glucose monitoring
-
I. Abdel-Hamid, P. Atanasov, E. Wilkins, Development of a needle-type biosensor for intravascular glucose monitoring, Anal. Chim. Acta 313 (1995) 45-54.
-
(1995)
Anal. Chim. Acta
, vol.313
, pp. 45-54
-
-
Abdel-Hamid, I.1
Atanasov, P.2
Wilkins, E.3
-
9
-
-
0025762856
-
One-step fabrication of glucose sensors based on entrapment of glucose oxidase within poly(ester-sulfonic acid) coatings
-
J. Wang, D. Leech, M. Ozsoz, S. Martinez, M.R. Smyth, One-step fabrication of glucose sensors based on entrapment of glucose oxidase within poly(ester-sulfonic acid) coatings, Anal. Chim. Acta 245 (1991) 139-143.
-
(1991)
Anal. Chim. Acta
, vol.245
, pp. 139-143
-
-
Wang, J.1
Leech, D.2
Ozsoz, M.3
Martinez, S.4
Smyth, M.R.5
-
10
-
-
0026628622
-
Amperometirc needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials
-
C.Y. Chen, M. Gotoh, H. Makino, Y.C. Su, E. Tamiya, I. Karube, Amperometirc needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials, Anal. Chim. Acta 265 (1992) 5-14.
-
(1992)
Anal. Chim. Acta
, vol.265
, pp. 5-14
-
-
Chen, C.Y.1
Gotoh, M.2
Makino, H.3
Su, Y.C.4
Tamiya, E.5
Karube, I.6
-
11
-
-
0021892334
-
Application of 1-(+)-Lactate electrode for clinical analysis and monitoring of tissue culture medium
-
T. Tsuchida, H. Takasugi, K. Yoda, K. Takizawa, S. Kobayashi, Application of 1-(+)-Lactate electrode for clinical analysis and monitoring of tissue culture medium, Biotechnol. Bioeng. 27 (1985) 837-841.
-
(1985)
Biotechnol. Bioeng.
, vol.27
, pp. 837-841
-
-
Tsuchida, T.1
Takasugi, H.2
Yoda, K.3
Takizawa, K.4
Kobayashi, S.5
-
12
-
-
0027415524
-
Modification of electrode surfaces with oxidised phenols to confer selectivity to amperometric biosensors for glucose determination
-
I.M. Christie, P. Vadgama, S. Lloyd, Modification of electrode surfaces with oxidised phenols to confer selectivity to amperometric biosensors for glucose determination, Anal. Chim. Acta 274 (1993) 191-199.
-
(1993)
Anal. Chim. Acta
, vol.274
, pp. 191-199
-
-
Christie, I.M.1
Vadgama, P.2
Lloyd, S.3
-
13
-
-
0029030631
-
Tuning of glucose oxidase modified alkylacrylate polymers employed in amperometric sensor systems
-
C.E. Hall, E.A.H. Hall, Tuning of glucose oxidase modified alkylacrylate polymers employed in amperometric sensor systems, Anal. Chim. Acta 310 (1995) 199-210.
-
(1995)
Anal. Chim. Acta
, vol.310
, pp. 199-210
-
-
Hall, C.E.1
Hall, E.A.H.2
-
14
-
-
0030584128
-
Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors
-
S.K. Jung, G.S. Wilson, Polymeric mercaptosilane-modified platinum electrodes for elimination of interferants in glucose biosensors, Anal. Chem. 68 (1996) 591-596.
-
(1996)
Anal. Chem.
, vol.68
, pp. 591-596
-
-
Jung, S.K.1
Wilson, G.S.2
-
15
-
-
0005756515
-
Elimination of ascorbate interference of glucose biosensors by use of enzyme multi-layers composed of avidin and biotin-labeled glucose oxidase and ascorbate oxidase
-
J. Anzai, H. Takeshita, T. Hoshi, T. Osa, Elimination of ascorbate interference of glucose biosensors by use of enzyme multi-layers composed of avidin and biotin-labeled glucose oxidase and ascorbate oxidase, Denki Kagaku 63 (1995) 1141-1142.
-
(1995)
Denki Kagaku
, vol.63
, pp. 1141-1142
-
-
Anzai, J.1
Takeshita, H.2
Hoshi, T.3
Osa, T.4
-
17
-
-
0029256699
-
Galactose biosensors using composite polymers to prevent interferences
-
P. Manowitz, P.W. Stoecker, A.M. Yacynych, Galactose biosensors using composite polymers to prevent interferences, Biosens. Bioelectron. 10 (1995) 359-370.
-
(1995)
Biosens. Bioelectron.
, vol.10
, pp. 359-370
-
-
Manowitz, P.1
Stoecker, P.W.2
Yacynych, A.M.3
-
18
-
-
0025871173
-
Miniaturized thin-film biosensors using covalently immobilized glucose oxidase
-
G. Urban, G. Jobst, F. Kohl, A. Jachimowicz, F. Olcaytug, O. Tilado, P. Goiser, G. Nauer, F. Pittner, T. Schalkhammer, E. Mann-Buxbaum, Miniaturized thin-film biosensors using covalently immobilized glucose oxidase, Biosens. Bioelectron. 6 (1991) 555-562.
-
(1991)
Biosens. Bioelectron.
, vol.6
, pp. 555-562
-
-
Urban, G.1
Jobst, G.2
Kohl, F.3
Jachimowicz, A.4
Olcaytug, F.5
Tilado, O.6
Goiser, P.7
Nauer, G.8
Pittner, F.9
Schalkhammer, T.10
Mann-Buxbaum, E.11
|