메뉴 건너뛰기




Volumn 17, Issue 7, 2002, Pages 936-941

Vertical acetabular positioning with an inclinometer in total hip arthroplasty

Author keywords

Abduction angle; Acetabulum; Hip prosthesis; Inclinometer

Indexed keywords

ACETABULUM; ARTICLE; CADAVER; CONTROLLED STUDY; DEPTH PERCEPTION; HUMAN; HUMAN TISSUE; INCLINOMETER; MALE; MEASUREMENT; PROBABILITY; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS;

EID: 0036787719     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1054/arth.2002.34820     Document Type: Article
Times cited : (17)

References (35)
  • 1
    • 0028284420 scopus 로고
    • Charnley low friction arthroplasty of the hip: Twenty-year results with cement
    • Kavanagh BF, Wallrichs S, Dewitz M, et al: Charnley low friction arthroplasty of the hip: twenty-year results with cement. J Arthroplasty 9:229, 1994
    • (1994) J Arthroplasty , vol.9 , pp. 229
    • Kavanagh, B.F.1    Wallrichs, S.2    Dewitz, M.3
  • 2
    • 0025995645 scopus 로고
    • A comparison of quality of life before and after arthroplasty in patient who had arthrosis of the hip joint
    • Wickland I, Romanus B: A comparison of quality of life before and after arthroplasty in patient who had arthrosis of the hip joint. J Bone Joint Surg Am 73:765, 1991
    • (1991) J Bone Joint Surg Am , vol.73 , pp. 765
    • Wickland, I.1    Romanus, B.2
  • 3
    • 0027750744 scopus 로고
    • The effect of elective total hip replacement on health related quality of life
    • Laupacis A, Bourne R, Rorarbeck C, et al: The effect of elective total hip replacement on health related quality of life. J Bone Joint Surg Am 75:1619, 1993
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 1619
    • Laupacis, A.1    Bourne, R.2    Rorarbeck, C.3
  • 5
    • 0017859205 scopus 로고
    • Dislocation after total hip replacement arthroplasties
    • Lewinnek GE, Lewis JL, Tarr R, et al: Dislocation after total hip replacement arthroplasties. J Bone Joint Surg Am 60:217, 1978
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 217
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3
  • 6
    • 0025679123 scopus 로고
    • Dislocation after total hip arthroplasty: Causes and prevention
    • McCollum DE, Gray WJ: Dislocation after total hip arthroplasty: causes and prevention. Clin Orthop 261:159, 1990
    • (1990) Clin Orthop , vol.261 , pp. 159
    • McCollum, D.E.1    Gray, W.J.2
  • 7
    • 0034012520 scopus 로고    scopus 로고
    • The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios
    • D'Lima DD, Urquhart AG, Buehler KO, et al: The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am 82:315, 2000
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 315
    • D'Lima, D.D.1    Urquhart, A.G.2    Buehler, K.O.3
  • 8
    • 0032801048 scopus 로고    scopus 로고
    • The effect of acetabular cup orientations on limiting hip rotation
    • Kummer FJ, Shah S, Iyer S, DiCesare PE: The effect of acetabular cup orientations on limiting hip rotation. J Arthroplasty 14:509, 1999
    • (1999) J Arthroplasty , vol.14 , pp. 509
    • Kummer, F.J.1    Shah, S.2    Iyer, S.3    DiCesare, P.E.4
  • 9
    • 0033166123 scopus 로고    scopus 로고
    • Ceramic cups for hip endoprotheses: 6. Cup design, inclination and antetorsion angle modify range of motion and impingement
    • Bader R, Willmann G: Ceramic cups for hip endoprotheses: 6. cup design, inclination and antetorsion angle modify range of motion and impingement. Biomed Tech (Berl) 44:209, 1999
    • (1999) Biomed Tech (Berl) , vol.44 , pp. 209
    • Bader, R.1    Willmann, G.2
  • 10
    • 0033385696 scopus 로고    scopus 로고
    • Ceramic acetabular cups for hip endoprostheses: 7. How do position of the centre of rotation and the CCD angle of the shaft modify range of motion and impingement
    • Bader R, Willmann G: Ceramic acetabular cups for hip endoprostheses: 7. how do position of the centre of rotation and the CCD angle of the shaft modify range of motion and impingement. Biomed Tech (Berl) 44:345, 1999
    • (1999) Biomed Tech (Berl) , vol.44 , pp. 345
    • Bader, R.1    Willmann, G.2
  • 11
    • 0031172144 scopus 로고    scopus 로고
    • The role of backside polishing, cup angle and polyethylene thickness on the contact stresses in metal backed acetabular component
    • Kurtz SM, Edidin AA, Bartel DL: The role of backside polishing, cup angle and polyethylene thickness on the contact stresses in metal backed acetabular component. J Biomech 30:639, 1997
    • (1997) J Biomech , vol.30 , pp. 639
    • Kurtz, S.M.1    Edidin, A.A.2    Bartel, D.L.3
  • 12
    • 0032440129 scopus 로고    scopus 로고
    • Results of cemented metal-backed acetabular components: A 10-year-average follow-up study
    • Chen FS, Di Cesare PE, Kale AA, et al: Results of cemented metal-backed acetabular components: a 10-year-average follow-up study. J Arthroplasty 13:867, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 867
    • Chen, F.S.1    Di Cesare, P.E.2    Kale, A.A.3
  • 13
    • 0028198810 scopus 로고
    • The relationship between the design, position and articular wear of acetabular component inserted without cement and the development of pelvic osteolysis
    • Schmalzried TP: The relationship between the design, position and articular wear of acetabular component inserted without cement and the development of pelvic osteolysis. J Bone Joint Surg Am 76:677, 1994
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 677
    • Schmalzried, T.P.1
  • 14
    • 0010592347 scopus 로고
    • Aseptic loosening: Fifteen years experience with the Muller total hip arthroplasty
    • Proceedings of the 39th Canadian Orthopeadic Association Meeting, Québec, 1983
    • McBroom R, Muller M: Aseptic loosening: fifteen years experience with the Muller total hip arthroplasty. Proceedings of the 39th Canadian Orthopeadic Association Meeting, Québec, 1983. J Bone Joint Surg Br 66:300, 1984
    • (1984) J Bone Joint Surg Br , vol.66 , pp. 300
    • McBroom, R.1    Muller, M.2
  • 15
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
    • Kennedy JG, Roger WB, Soffe KE, et al: Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13:530, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 530
    • Kennedy, J.G.1    Roger, W.B.2    Soffe, K.E.3
  • 16
    • 0025393979 scopus 로고
    • Analysis of removed Autophore ceramic-on-ceramic components
    • Kummer FJ, Stuchin SA, Frankle VH: Analysis of removed Autophore ceramic-on-ceramic components. J Arthroplasty 5:509, 1990
    • (1990) J Arthroplasty , vol.5 , pp. 509
    • Kummer, F.J.1    Stuchin, S.A.2    Frankle, V.H.3
  • 18
    • 0036056821 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip arthroplasty: A minimum 18.5-year follow-up study
    • Hamadouche M, Boutin P, Daussange J, et al: Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 84:69, 2002
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 69
    • Hamadouche, M.1    Boutin, P.2    Daussange, J.3
  • 20
    • 0024255826 scopus 로고
    • The use of dense alumina-alumina ceramic combinations in total hip replacement
    • Boutin P, Christel P, Dorlot JM, et al: The use of dense alumina-alumina ceramic combinations in total hip replacement. J Biomed Mater Res 22:1203, 1988
    • (1988) J Biomed Mater Res , vol.22 , pp. 1203
    • Boutin, P.1    Christel, P.2    Dorlot, J.M.3
  • 21
    • 0022481856 scopus 로고
    • The inclination of the weight bearing surface in the hip joint: The clinical significance of abnormal force
    • Maistrelli G, Gerundini M, Bombelli R: The inclination of the weight bearing surface in the hip joint: the clinical significance of abnormal force. Orthop Rev 15:271, 1986
    • (1986) Orthop Rev , vol.15 , pp. 271
    • Maistrelli, G.1    Gerundini, M.2    Bombelli, R.3
  • 23
    • 0025295098 scopus 로고
    • Alumina on alumina hip replacement: Results and survivorship in young patients
    • Sedel L, Kerboull L, Christel P, et al: Alumina on alumina hip replacement: results and survivorship in young patients. J Bone Joint Surg Br 72:658, 1990
    • (1990) J Bone Joint Surg Br , vol.72 , pp. 658
    • Sedel, L.1    Kerboull, L.2    Christel, P.3
  • 24
    • 0010629942 scopus 로고
    • Editorial: Ceramic hips
    • Sedel L: Editorial: ceramic hips. J Bone Joint Surg Br 79:331, 1992
    • (1992) J Bone Joint Surg Br , vol.79 , pp. 331
    • Sedel, L.1
  • 25
    • 0010560483 scopus 로고
    • Biomechanics of total hip arthroplasty
    • Imura S: Biomechanics of total hip arthroplasty. East Jpn J Clin Orthop 7:609, 1995
    • (1995) East Jpn J Clin Orthop , vol.7 , pp. 609
    • Imura, S.1
  • 26
    • 0000020883 scopus 로고    scopus 로고
    • Arthroplasty of the hip
    • Crenshaw AH (ed). Mosby, St. Louis
    • Harkess WJ: Arthroplasty of the hip. p. 535. In Crenshaw AH (ed): Campbell's operative orthopaedics. Mosby, St. Louis, 1998
    • (1998) Campbell's operative orthopaedics , pp. 535
    • Harkess, W.J.1
  • 27
    • 0032124945 scopus 로고    scopus 로고
    • Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer aided design simulation
    • Seki M, Yuasa N, Ohkuni K: Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer aided design simulation. J Orthop Res 16:513, 1998
    • (1998) J Orthop Res , vol.16 , pp. 513
    • Seki, M.1    Yuasa, N.2    Ohkuni, K.3
  • 28
    • 0031894930 scopus 로고    scopus 로고
    • Accuracy of intraoperative assessment of acetabular prosthesis placement
    • Hassan DM, Johnston GH, Dust WN, et al: Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty 13:80, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 80
    • Hassan, D.M.1    Johnston, G.H.2    Dust, W.N.3
  • 29
    • 0023943689 scopus 로고
    • Comparison of two and three dimensional methods for assessment of orientation of total hip prosthesis
    • Herlin K, Petterson H, Sevlik G: Comparison of two and three dimensional methods for assessment of orientation of total hip prosthesis. Acta Radiol 29:357, 1988
    • (1988) Acta Radiol , vol.29 , pp. 357
    • Herlin, K.1    Petterson, H.2    Sevlik, G.3
  • 30
    • 0010595280 scopus 로고
    • The effect of pelvic rotation on alpha and theta angles in total hip arthroplasty
    • Seller R, Lyles D, Dorr L: The effect of pelvic rotation on alpha and theta angles in total hip arthroplasty. Contemp Orthop 17:67, 1988
    • (1988) Contemp Orthop , vol.17 , pp. 67
    • Seller, R.1    Lyles, D.2    Dorr, L.3
  • 32
    • 0029582771 scopus 로고
    • Can simple radiographs be predictive of total hip dislocation?
    • Pollard JA, Daum WJ, Uchida T: Can simple radiographs be predictive of total hip dislocation? J Arthroplasty 10:800, 1995
    • (1995) J Arthroplasty , vol.10 , pp. 800
    • Pollard, J.A.1    Daum, W.J.2    Uchida, T.3
  • 33
    • 0019997368 scopus 로고
    • Radiologic evaluation of the position of the acetabular component of the total hip prosthesis
    • Petterson H, Gentz CF, Lindberg HO, Carlsson AS: Radiologic evaluation of the position of the acetabular component of the total hip prosthesis. Acta Radiol Diag 23:259, 1982
    • (1982) Acta Radiol Diag , vol.23 , pp. 259
    • Petterson, H.1    Gentz, C.F.2    Lindberg, H.O.3    Carlsson, A.S.4
  • 34
    • 0031717594 scopus 로고    scopus 로고
    • Effect of acetabular abduction on cup wear rates in total hip arthroplasty
    • Del Schutte H, Lipman AJ, Bannar SM, et al: Effect of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty 13:621, 1998
    • (1998) J Arthroplasty , vol.13 , pp. 621
    • Del Schutte, H.1    Lipman, A.J.2    Bannar, S.M.3
  • 35
    • 0026738353 scopus 로고
    • Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis
    • Nizard RS, Sedel L, Christel P, et al: Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop 282:53, 1992
    • (1992) Clin Orthop , vol.282 , pp. 53
    • Nizard, R.S.1    Sedel, L.2    Christel, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.