메뉴 건너뛰기




Volumn 44, Issue 7-8, 1999, Pages 212-219

Ceramic acetabular cups for total hip replacement part 6: Cup design, inclination angle and antetorsion angle have an influence on the range of motion and impingement;Keramischer pfannen fur huftendoprothesen teil 6: Pfannendesign, inklinations- und antetorsionswinkel beeinflussen bewegungsumfang und impingement

Author keywords

Ceramic insert; Ceramic on ceramic; Cup design; Dislocation; Hip endoprostheses; Impingement

Indexed keywords

BIOMECHANICS; CERAMIC MATERIALS; COMPUTER AIDED DIAGNOSIS; COMPUTER SIMULATION; JOINTS (ANATOMY); ORTHOPEDICS;

EID: 0033166123     PISSN: 00135585     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (43)

References (16)
  • 1
    • 0016707369 scopus 로고
    • Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus
    • Amstutz H. C., R. M. Lodwig, D. J. Schurman, A. G. Hodgsen: Range of Motion Studies for Total Hip Replacements. A Comparative Study with a New Experimental Apparatus. Clin Orthop 111 (1975), 124-130.
    • (1975) Clin Orthop , vol.111 , pp. 124-130
    • Amstutz, H.C.1    Lodwig, R.M.2    Schurman, D.J.3    Hodgsen, A.G.4
  • 4
    • 84956694744 scopus 로고    scopus 로고
    • Range of motion after total hip arthroplasty: Experimental verification of the analytical simulator
    • Troccaz J., E. Grimson, R. Mösges (eds.): Lecture Notes in Computer Science. Berlin
    • Jaramaz B., C. Nikou, D. A. Simon, A. M. DiGioia: Range of Motion After Total Hip Arthroplasty: Experimental Verification of the Analytical Simulator. In: Troccaz J., E. Grimson, R. Mösges (eds.): Lecture Notes in Computer Science. CVRMed-MRCAS '97, Berlin 1997, 573-582.
    • (1997) CVRMed-MRCAS '97 , pp. 573-582
    • Jaramaz, B.1    Nikou, C.2    Simon, D.A.3    DiGioia, A.M.4
  • 6
    • 0025679123 scopus 로고
    • Dislocation after total hip arthroplasty
    • McCollum D. E., W. J. Gray: Dislocation After Total Hip Arthroplasty. Clin. Orthop. 261 (1990), 159-170.
    • (1990) Clin. Orthop. , vol.261 , pp. 159-170
    • McCollum, D.E.1    Gray, W.J.2
  • 7
    • 0002410041 scopus 로고
    • Springer Verlag, Berlin Heidelberg New York
    • Morscher, E. W. (ed.): Endoprothetik. Springer Verlag, Berlin Heidelberg New York 1995.
    • (1995) Endoprothetik
    • Morscher, E.W.1
  • 10
    • 0031016456 scopus 로고    scopus 로고
    • Joint motion and surface contact area related to component position in total hip arthroplasty
    • Br
    • Robinson R. P., P. T. Simonian, I. M. Gradisar, R. P. Ching: Joint Motion And Surface Contact Area Related To Component Position In Total Hip Arthroplasty. J. Bone and Joint Surg. (Br) 79-B (1997), 140-146.
    • (1997) J. Bone and Joint Surg. , vol.79 B , pp. 140-146
    • Robinson, R.P.1    Simonian, P.T.2    Gradisar, I.M.3    Ching, R.P.4
  • 13
    • 0032124945 scopus 로고    scopus 로고
    • Analysis of optimal range of socket orientations in total hip arthroplasty with use of computer-aided design simulation
    • Seki M., N. Yuasa, K. Ohkuni: Analysis of Optimal Range of Socket Orientations in Total Hip Arthroplasty with Use of Computer-Aided Design Simulation. J. Orthop. Res. 16, (1998), 513-517.
    • (1998) J. Orthop. Res. , vol.16 , pp. 513-517
    • Seki, M.1    Yuasa, N.2    Ohkuni, K.3
  • 14
    • 0028501353 scopus 로고
    • Über die bedeutung der position der endoprothesenpfanne aus biomechanischer und klinischer sicht - Vorschlag einer klassifizierung
    • Thomas W., M. Schug: Über die Bedeutung der Position der Endoprothesenpfanne aus biomechanischer und klinischer Sicht - Vorschlag einer Klassifizierung. Biomed. Technik 39 (1994), 222-226.
    • (1994) Biomed. Technik , vol.39 , pp. 222-226
    • Thomas, W.1    Schug, M.2
  • 16
    • 0031239994 scopus 로고    scopus 로고
    • Keramische pfannen für hüftendoprothesen teil 3: Zum problem der osteointegration monolithischer pfannen
    • Willmann, G.: Keramische Pfannen für Hüftendoprothesen Teil 3: Zum Problem der Osteointegration monolithischer Pfannen. Biomed. Technik 42 (1997), 256-263.
    • (1997) Biomed. Technik , vol.42 , pp. 256-263
    • Willmann, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.