메뉴 건너뛰기




Volumn 29, Issue 12, 2002, Pages 1588-1593

Cardiac phantom measurement validating the methodology for a cardiac multi-centre trial with positron emission tomography

Author keywords

Defect size; Myocardial perfusion; Positron emission tomography

Indexed keywords

ACCURACY; ARTICLE; AUTOANALYSIS; CLINICAL PROTOCOL; CLINICAL TRIAL; HEART DISEASE; HUMAN; METHODOLOGY; MULTICENTER STUDY; PHANTOM; POSITRON EMISSION TOMOGRAPHY; REPRODUCIBILITY; STATISTICAL ANALYSIS; VALIDATION PROCESS; BLOOD CLOT LYSIS; COMPUTER PROGRAM; HEART INFARCTION; HEART LEFT VENTRICLE; IMAGE DISPLAY; COMPARATIVE STUDY; COMPUTER ASSISTED EMISSION TOMOGRAPHY; EQUIPMENT DESIGN; EUROPE; EVALUATION; HEART; HEART VENTRICLE; IMAGE QUALITY; INSTRUMENTATION; ISRAEL; QUALITY CONTROL; SCINTISCANNING; SENSITIVITY AND SPECIFICITY; STANDARD; VALIDATION STUDY;

EID: 0036451981     PISSN: 03406997     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00259-002-0940-0     Document Type: Article
Times cited : (5)

References (15)
  • 1
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson MH, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994; 13:601-609.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, M.H.1    Larkin, R.S.2
  • 2
    • 0029299915 scopus 로고
    • Objective assessment of image quality. II. Fisher information, Fourier crosstalk, and figures of merit for task performance
    • Barrett HH, Denny JL, Wagner RF, Myers KJ. Objective assessment of image quality. II. Fisher information, Fourier crosstalk, and figures of merit for task performance. J Opt Soc Am [A] 1995; 12:834-852.
    • (1995) J Opt Soc Am [A] , vol.12 , pp. 834-852
    • Barrett, H.H.1    Denny, J.L.2    Wagner, R.F.3    Myers, K.J.4
  • 5
    • 0028807868 scopus 로고
    • Impaired myocardial tissue perfusion early after successful thrombolysis, impact on myocardial flow, metabolism and function at late follow-up
    • Maes A, Van de Werf F, Nuyts J, Bormans G, Desmet W, Mortelmans L. Impaired myocardial tissue perfusion early after successful thrombolysis, impact on myocardial flow, metabolism and function at late follow-up. Circulation 1995; 92:2072-2078.
    • (1995) Circulation , vol.92 , pp. 2072-2078
    • Maes, A.1    Van de Werf, F.2    Nuyts, J.3    Bormans, G.4    Desmet, W.5    Mortelmans, L.6
  • 6
    • 0031210462 scopus 로고    scopus 로고
    • PET with F-18 fluoride: Effects of iterative versus filtered backprojection reconstruction on kinetic modeling
    • Schiepers C, Nuyts J, Wu C, Verma R. PET with F-18 fluoride: effects of iterative versus filtered backprojection reconstruction on kinetic modeling. IEEE Trans Nucl Sci 1997, 44:1591-1593.
    • (1997) IEEE Trans Nucl Sci , vol.44 , pp. 1591-1593
    • Schiepers, C.1    Nuyts, J.2    Wu, C.3    Verma, R.4
  • 7
    • 0035555251 scopus 로고    scopus 로고
    • Factor analysis for delineation of organ structures and automatic generation of in- and output functions in PET studies of prostate cancer
    • November 6-11, San Diego, Calif. USA
    • Schiepers C, Wu C, Seltzer M, Phelps M, Dahlbom M, Hoh C, Nuyts J. Factor analysis for delineation of organ structures and automatic generation of in- and output functions in PET studies of prostate cancer. Proceedings of the IEEE NSS and MIC, November 6-11, 2001, San Diego, Calif. USA.
    • (2001) Proceedings of the IEEE NSS and MIC
    • Schiepers, C.1    Wu, C.2    Seltzer, M.3    Phelps, M.4    Dahlbom, M.5    Hoh, C.6    Nuyts, J.7
  • 8
    • 0035000317 scopus 로고    scopus 로고
    • Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: Quantitative characteristics and effects on kinetic modeling
    • Boellaard R, van Lingen A, Lammertsma AA. Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling. J Nucl Med 2001; 42:808-817.
    • (2001) J Nucl Med , vol.42 , pp. 808-817
    • Boellaard, R.1    Van Lingen, A.2    Lammertsma, A.A.3
  • 10
    • 0034195227 scopus 로고    scopus 로고
    • Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction
    • Stayman JW, Fessler FA. Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction. IEEE Trans Med Imaging 2000; 19:601-615.
    • (2000) IEEE Trans Med Imaging , vol.19 , pp. 601-615
    • Stayman, J.W.1    Fessler, F.A.2
  • 11
    • 0030085857 scopus 로고    scopus 로고
    • Practical considerations for 3D image reconstruction using spherically symmetric volume elements
    • Matej S, Lewitt RM. Practical considerations for 3D image reconstruction using spherically symmetric volume elements. IEEE Trans Med Imaging 1996; 15:68-78.
    • (1996) IEEE Trans Med Imaging , vol.15 , pp. 68-78
    • Matej, S.1    Lewitt, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.