메뉴 건너뛰기




Volumn 44, Issue 4 PART 1, 1997, Pages 1591-1593

PET with18F-Fluoride: Effects of iterative versus filtered backprojection reconstruction on kinetic modeling

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; IMAGE RECONSTRUCTION; ITERATIVE METHODS; MATHEMATICAL MODELS; POSITRON EMISSION TOMOGRAPHY; RADIOISOTOPES;

EID: 0031210462     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/23.632737     Document Type: Article
Times cited : (11)

References (7)
  • 1
    • 0027398350 scopus 로고    scopus 로고
    • The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction. 1993; 38: pp. 55-70
    • J.S. Liow, S.C. Strother. "The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction. Phys Med Biol, 1993; 38: pp. 55-70
    • Phys Med Biol
    • Liow, J.S.1    Strother, S.C.2
  • 2
    • 0028896737 scopus 로고    scopus 로고
    • P. Dupont, V. Van den Maegdenbergh, S. Vleugels, P. Suetens, L. Mortelmans. A study of the liver-heart artifact in emission tomography. 1995; 36: pp. 133-139
    • J. Nuyts, P. Dupont, V. Van den Maegdenbergh, S. Vleugels, P. Suetens, L. Mortelmans. "A study of the liver-heart artifact in emission tomography." J Nucl Med, 1995; 36: pp. 133-139
    • J Nucl Med
    • Nuyts, J.1
  • 3
    • 0028700063 scopus 로고    scopus 로고
    • R.S. Larkin. Accelerated image reconstruction using ordered subsets of projection data, 1994; 13: pp. 601-609
    • M.H. Hudson, R.S. Larkin. "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans MI, 1994; 13: pp. 601-609
    • IEEE Trans MI
    • Hudson, M.H.1
  • 4
    • 33747808423 scopus 로고    scopus 로고
    • P. Dupont, C. Schiepers, L. Mortelmans. Efficient storage of the detection probability matrix for reconstruction in PET, 1994; 35: p. S187
    • J. Nuyts, P. Dupont, C. Schiepers, L. Mortelmans. "Efficient storage of the detection probability matrix for reconstruction in PET," J Nucl Med, 1994; 35: p. S187
    • J Nucl Med
    • Nuyts, J.1
  • 5
    • 0026648265 scopus 로고    scopus 로고
    • 18F-fluoride ion with PET, 1992; 33: pp. 633-642
    • 18F-fluoride ion with PET," J Nucl Med, 1992; 33: pp. 633-642
    • J Nucl Med
    • Hawkins, R.A.1
  • 6
    • 0028496882 scopus 로고    scopus 로고
    • Y. Yan, B. Chodowski, T.K. Yap, M.E. Daube-Witherspoon. Precision and accuracy or regional radioactivity quantitation using maximum likelihood EM reconstruction algorithms. 1994; 13: pp. 526-537
    • R.E. Carson, Y. Yan, B. Chodowski, T.K. Yap, M.E. Daube-Witherspoon. "Precision and accuracy or regional radioactivity quantitation using maximum likelihood EM reconstruction algorithms." IEEE Trans MI, 1994; 13: pp. 526-537
    • IEEE Trans MI
    • Carson, R.E.1
  • 7
    • 0029805550 scopus 로고    scopus 로고
    • R.M. Leahy, S.R. Cherry. Bayesian reconstruction of PET images: methodology and performance analysis. 1996; 41: pp. 1777-1807
    • E.U. Mumcuoglu, R.M. Leahy, S.R. Cherry. "Bayesian reconstruction of PET images: methodology and performance analysis." Phys Med Biol, 1996; 41: pp. 1777-1807
    • Phys Med Biol
    • Mumcuoglu, E.U.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.