Volumn 38, Issue 10, 1997, Pages 1614-1623

Performance evaluation of a whole-body PET scanner using the NEMA protocol

Author keywords

NEMA protocol; PET

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; HUMAN; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; WHOLE BODY SCINTISCANNING;

EID: 9844227354     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (449)

References (17)
  • 1
    • 0026323156 scopus 로고
    • Performance standards in positron emission tomography
    • Karp JS, Daube-Witherspoon ME, Hoffman EJ, et al. Performance standards in positron emission tomography. J Nucl Med 1991;12:2342-2350.
    • (1991) J Nucl Med , vol.12 , pp. 2342-2350
    • Karp, J.S.1    Daube-Witherspoon, M.E.2    Hoffman, E.J.3
  • 2
    • 0003710949 scopus 로고
    • National Electrical Manufacturers Association
    • NEMA Standards Publication NU 2-1994. National Electrical Manufacturers Association, 1994.
    • (1994) NEMA Standards Publication NU 2-1994
  • 3
    • 0024610693 scopus 로고
    • Analytical three-dimensional image reconstruction using all detected events
    • Kinahan P, Rogers JG. Analytical three-dimensional image reconstruction using all detected events. IEEE Trans Nucl Sci 1989;36:964-968.
    • (1989) IEEE Trans Nucl Sci , vol.36 , pp. 964-968
    • Kinahan, P.1    Rogers, J.G.2
  • 5
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections. J Comput Assist Tomogr 1983;7:42-50.
    • (1983) J Comput Assist Tomogr , vol.7 , pp. 42-50
    • Bergström, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 6
    • 0027287252 scopus 로고
    • Scatter correction in the transaxial slices of a whole-body positron emission tomograph
    • Hoverath H, Kuebler WK, Ostertag HJ, et al. Scatter correction in the transaxial slices of a whole-body positron emission tomograph. Phys Med Biol 1993;38:717-728.
    • (1993) Phys Med Biol , vol.38 , pp. 717-728
    • Hoverath, H.1    Kuebler, W.K.2    Ostertag, H.J.3
  • 7
    • 0001320737 scopus 로고    scopus 로고
    • A single scatter simulation technique for scatter correction in three-dimensional PET
    • Grangeat P, Amans JL, eds. Dordrecht, The Netherlands: Kluwer
    • Watson CC, Newport D, Casey ME. A single scatter simulation technique for scatter correction in three-dimensional PET. In: Grangeat P, Amans JL, eds. Three-dimensional image reconstruction in radiology and nuclear medicine. Dordrecht, The Netherlands: Kluwer; 1996:255-268.
    • (1996) Three-dimensional Image Reconstruction in Radiology and Nuclear Medicine , pp. 255-268
    • Watson, C.C.1    Newport, D.2    Casey, M.E.3
  • 8
    • 0026319313 scopus 로고
    • Standards for performance measurements of PET scanners: Evaluation with the UGM PENN-PET 240H scanner
    • Karp JS, Muehllehner G. Standards for performance measurements of PET scanners: evaluation with the UGM PENN-PET 240H scanner. Med Prog Technol 1991;17:173-187.
    • (1991) Med Prog Technol , vol.17 , pp. 173-187
    • Karp, J.S.1    Muehllehner, G.2
  • 9
    • 0026725290 scopus 로고
    • Standardized tests of PET performance
    • Bice AN, Miyaoka RS. Standardized tests of PET performance. J Nucl Med 1992;33:1429-1430.
    • (1992) J Nucl Med , vol.33 , pp. 1429-1430
    • Bice, A.N.1    Miyaoka, R.S.2
  • 15
    • 0027169779 scopus 로고
    • A rotating PET scanner using BGO block detectors; design, performance and applications
    • Townsend DW, Wensveen M, Byars LG, et al. A rotating PET scanner using BGO block detectors; design, performance and applications. J Nucl Med 1993;34:1367-1376.
    • (1993) J Nucl Med , vol.34 , pp. 1367-1376
    • Townsend, D.W.1    Wensveen, M.2    Byars, L.G.3
  • 16
    • 0001569189 scopus 로고
    • Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors
    • Moses WW, Derenzo SE. Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors. J Nucl Med 1993;34: 101P.
    • (1993) J Nucl Med , vol.34
    • Moses, W.W.1    Derenzo, S.E.2
  • 17
    • 0025780950 scopus 로고
    • Three-dimensional PET using a conventional multislice tomograph without septa
    • Cherry SR, Dahlbom M, Hoffmann EJ, Three-dimensional PET using a conventional multislice tomograph without septa. J Comput Assist Tomogr 1991;15:655-668.
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 655-668
    • Cherry, S.R.1    Dahlbom, M.2    Hoffmann, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.