메뉴 건너뛰기




Volumn 100, Issue 1-4, 2002, Pages 353-356

Influence of readout parameters on TL response, re-usability and residual signal in LiF:Mg,Cu,P

Author keywords

[No Author keywords available]

Indexed keywords

COPPER; LITHIUM FLUORIDE; MAGNESIUM; PHOSPHORUS;

EID: 0036387972     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a005887     Document Type: Article
Times cited : (10)

References (15)
  • 1
    • 0003410393 scopus 로고
    • Thermoluminescence Dosimetry-Materials: Properties and Uses
    • (Ashford, UK: Nuclear Technology Publishing)
    • Mckeever, S. W. S., Moscovitch, M. and Townsend, P. D. Thermoluminescence Dosimetry-Materials: Properties and Uses (Ashford, UK: Nuclear Technology Publishing) (1995).
    • (1995)
    • Mckeever, S.W.S.1    Moscovitch, M.2    Townsend, P.D.3
  • 2
    • 13044305291 scopus 로고    scopus 로고
    • State of the Art of Environmental Dosimetry: 11th International Intercomparison and Proposed Performance Tests
    • and 11 others
    • Klemic, G. and 11 others. State of the Art of Environmental Dosimetry: 11th Intarnational Intercomparison and Proposed Performance Tests. Radiat. Prot. Dosim. 85(1-4), 201-206 (1999).
    • (1999) Radiat. Prot. Dosim , vol.85 , Issue.1-4 , pp. 201-206
    • Klemic, G.1
  • 3
    • 0033787970 scopus 로고    scopus 로고
    • Recent Developments of Passive and Active Detectors Used in the Monitoring of External Environmental Radiation
    • Saez-Vergara, J. C. Recent Developments of Passive and Active Detectors Used in the Monitoring of External Environmental Radiation. Radiat. Prot. Dosim. 92(1-3), 83-88 (2000).
    • (2000) Radiat. Prot. Dosim , vol.92 , Issue.1-3 , pp. 83-88
    • Saez-Vergara, J.C.1
  • 4
    • 0000476818 scopus 로고    scopus 로고
    • Recent Improvements in LiF:Mg,Ti and LiF:Mg,Cu,P Based Environmental Dosimetry
    • Delgado, A. Recent Improvements in LiF:Mg,Ti and LiF:Mg,Cu,P Based Environmental Dosimetry. Radiat. Prot. Dosim. 66 (1-4), 101-104 (1996).
    • (1996) Radiat. Prot. Dosim , vol.66 , Issue.1-4 , pp. 101-104
    • Delgado, A.1
  • 5
    • 0032772827 scopus 로고    scopus 로고
    • An Improved LiF:Mg,Cu,P Chip with a Low Residual Signal
    • Tang. K., Cai, G., Shen, W.. Min, L. and Zhu, H. An Improved LiF:Mg,Cu,P Chip with a Low Residual Signal. Radiat. Prot. Dosim. 84 (1-4), 227-230 (1999).
    • (1999) Radiat. Prot. Dosim , vol.84 , Issue.1-4 , pp. 227-230
    • Tang, K.1    Cai, G.2    Shen, W.3    Min, L.4    Zhu, H.5
  • 6
    • 0002205227 scopus 로고    scopus 로고
    • Selection of a New Dosimetry System: One Utility's Experience
    • Hirning, C. R. Selection of a New Dosimetry System: One Utility's Experience. Radiat. Prot. Dosim. 66(1-4), 63-67 (1996).
    • (1996) Radiat. Prot. Dosim , vol.66 , Issue.1-4 , pp. 63-67
    • Hirning, C.R.1
  • 7
    • 0025155701 scopus 로고
    • Influence of The Cooling Rate on Repeatability of LiF:Mg,Cu,P Thermoluminescent Chips
    • Piters, T. M. and Bos, A. J. J. Influence of The Cooling Rate on Repeatability of LiF:Mg,Cu,P Thermoluminescent Chips. Radiat. Prot. Dosim. 33(1-4), 91-94 (1990).
    • (1990) Radiat. Prot. Dosim , vol.33 , Issue.1-4 , pp. 91-94
    • Piters, T.M.1    Bos, A.J.J.2
  • 8
    • 0010657169 scopus 로고    scopus 로고
    • Glow Curve Control of the Maximum Readout Temperature: Application to LiF GR-200
    • Gomez Ros, J. M., Burg, B., van der Muniz, J. L. and Delgado, A. Glow Curve Control of the Maximum Readout Temperature: Application to LiF GR-200. Radiat. Prot. Dosim. 66(1-4), 423-426 (1996).
    • (1996) Radiat. Prot. Dosim , vol.66 , Issue.1-4 , pp. 423-426
    • Gomez Ros, J.M.1    Burg, B.2    van der Muniz, J.L.3    Delgado, A.4
  • 9
    • 0001687576 scopus 로고    scopus 로고
    • The Influence of the Heating System on the Hypersensitive Thermoluminescence Materials LiF: Mg,Cu,P (GR-200)
    • Saez-Vergara, J. C. and Romero, A. M. The Influence of the Heating System on the Hypersensitive Thermoluminescence Materials LiF: Mg,Cu,P (GR-200). Radiat. Prot. Dosim. 66(1-4), 431-436 (1996).
    • (1996) Radiat. Prot. Dosim , vol.66 , Issue.1-4 , pp. 431-436
    • Saez-Vergara, J.C.1    Romero, A.M.2
  • 10
    • 0027730297 scopus 로고
    • Glow Curve Readout of LiF:Mg,Cu,P (GR-200) at Maximum Temperatures between 240°C and 280°C: Elimination of the Residual Signal
    • Oster, L., Horowitz, Y. S. and Horowitz, A. Glow Curve Readout of LiF:Mg,Cu,P (GR-200) at Maximum Temperatures between 240°C and 280°C: Elimination of the Residual Signal. Radiat. Prot. Dosim. 49(4), 407-411 (1993).
    • (1993) Radiat. Prot. Dosim , vol.49 , Issue.4 , pp. 407-411
    • Oster, L.1    Horowitz, Y.S.2    Horowitz, A.3
  • 14
    • 0022919646 scopus 로고
    • Measurement of Extremely Low Dose with LiF:Mg,Cu,P TL Chips
    • Zha, Z., Wang, S., Wu, F., Chen, G., Li, Y. and Zhu, J. Measurement of Extremely Low Dose with LiF:Mg,Cu,P TL Chips. Radiat. Prot. Dosim. 17(1-4), 415-418(1986).
    • (1986) Radiat. Prot. Dosim , vol.17 , Issue.1-4 , pp. 415-418
    • Zha, Z.1    Wang, S.2    Wu, F.3    Chen, G.4    Li, Y.5    Zhu, J.6
  • 15
    • 0036392823 scopus 로고    scopus 로고
    • New Advances in LiF:Mg,Cu,P TLDs (GR-200A)
    • (This issue)
    • Shen, W., Tang, K., Zhu, H. and Liu, B. New Advances in LiF:Mg,Cu,P TLDs (GR-200A). Rachat. Prot. Dosim. 100(1-4), 357-360 (This issue) (2002).
    • (2002) Rachat. Prot. Dosim , vol.100 , Issue.1-4 , pp. 357-360
    • Shen, W.1    Tang, K.2    Zhu, H.3    Liu, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.