메뉴 건너뛰기




Volumn 84, Issue 1-4, 1999, Pages 235-238

Investigation of the glow peak parameters, reusability and dosimetric precision of LiF:Mg,Cu,P at high heating rates up to 20 K.s-1

Author keywords

[No Author keywords available]

Indexed keywords

COPPER; LITHIUM FLUORIDE; MAGNESIUM; PHOSPHORUS;

EID: 0032794350     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a032726     Document Type: Conference Paper
Times cited : (17)

References (9)
  • 1
    • 0027268426 scopus 로고
    • LiF:Mg,Cu,P: The Competition Heats Up
    • Horowitz, Y. S. LiF:Mg,Cu,P: The Competition Heats Up. Radiat. Prot. Dosim. 47, 135-141 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 135-141
    • Horowitz, Y.S.1
  • 2
    • 0027240269 scopus 로고
    • Preparation and Characteristics of LiF:Mg,Cu,P Thermoluminescent Material
    • Zha, Z., Wang, S., Shen, W., Zhu, J. and Cai, G. Preparation and Characteristics of LiF:Mg,Cu,P Thermoluminescent Material. Radiat. Prot. Dosim. 47, 111-117 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 111-117
    • Zha, Z.1    Wang, S.2    Shen, W.3    Zhu, J.4    Cai, G.5
  • 3
    • 0025010017 scopus 로고
    • Characterisation of LiF:Mg,Cu,P (GR-200) for Personnel TLD
    • Horowitz, Y. S. and Horowitz, A. Characterisation of LiF:Mg,Cu,P (GR-200) for Personnel TLD. Radiat. Prot. Dosim. 33, 279-282 (1990).
    • (1990) Radiat. Prot. Dosim. , vol.33 , pp. 279-282
    • Horowitz, Y.S.1    Horowitz, A.2
  • 4
    • 0027730297 scopus 로고
    • Glow Curve Readout of LiF:Mg,Cu,P (GR-200) Chips at Maximum Temperatures between 240°C and 280°C: Elimination of the Residual Signal
    • Oster, L., Horowitz, Y. S. and Horowitz, A. Glow Curve Readout of LiF:Mg,Cu,P (GR-200) Chips at Maximum Temperatures between 240°C and 280°C: Elimination of the Residual Signal. Radiat. Prot. Dosim. 49, 407-411 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.49 , pp. 407-411
    • Oster, L.1    Horowitz, Y.S.2    Horowitz, A.3
  • 5
    • 0029842048 scopus 로고    scopus 로고
    • Further Studies of the Stability of LiF:Mg,Cu,P (GR-200) at Maximum Readout Temperatures between 240°C and 280°C
    • Oster, L., Horowitz, Y. S. and Horowitz, A. Further Studies of the Stability of LiF:Mg,Cu,P (GR-200) at Maximum Readout Temperatures between 240°C and 280°C. Radiat. Prot. Dosim. 65, 159-162 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.65 , pp. 159-162
    • Oster, L.1    Horowitz, Y.S.2    Horowitz, A.3
  • 7
    • 0017949317 scopus 로고
    • The Analysis of Thermoluminescent Glow Peaks in LiF(TLD-100)
    • Taylor, G. C. and Lilley, E. The Analysis of Thermoluminescent Glow Peaks in LiF(TLD-100). J. Phys, D: Appl. Phys. 11, 567-581 (1978).
    • (1978) J. Phys, D: Appl. Phys. , vol.11 , pp. 567-581
    • Taylor, G.C.1    Lilley, E.2
  • 8
    • 79952991429 scopus 로고
    • Effects of Cooling and Heating Rate on Trapping Parameters in LiF:Mg,Ti Crystals
    • Bos, A. J. J., Vijverberg, R. N. M., Piters, T. M. and McKeever, S. W. S. Effects of Cooling and Heating Rate on Trapping Parameters in LiF:Mg,Ti Crystals. J. Phys. D: Appl. Phys. 25, 1249-1257 (1992).
    • (1992) J. Phys. D: Appl. Phys. , vol.25 , pp. 1249-1257
    • Bos, A.J.J.1    Vijverberg, R.N.M.2    Piters, T.M.3    McKeever, S.W.S.4
  • 9
    • 9444235465 scopus 로고
    • Thermal Quenching of Luminescence in Six Thermoluminescent Dosimetry Phosphors
    • Gatlinburg, Tennessee
    • Gorbics, S. G., Nash, A. E. and Attix, F. H. Thermal Quenching of Luminescence in Six Thermoluminescent Dosimetry Phosphors. In: Proc. Second Int. Conf. On Luminescence Dosimetry, Gatlinburg, Tennessee, pp. 587-608 (1969).
    • (1969) Proc. Second Int. Conf. on Luminescence Dosimetry , pp. 587-608
    • Gorbics, S.G.1    Nash, A.E.2    Attix, F.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.