1
-
-
0003304896
-
Development of a New Highly Sensitive LiF Thermoluminescence Dosemeter and its Applications
-
Nakajima, T., Murayama, Y., Matsuzawa, T. and Koyano, A. Development of a New Highly Sensitive LiF Thermoluminescence Dosemeter and its Applications. Nucl. Instrum. Methods 157, 155-162 (1978).
-
(1978)
Nucl. Instrum. Methods
, vol.157
, pp. 155-162
-
-
Nakajima, T.1
Murayama, Y.2
Matsuzawa, T.3
Koyano, A.4
-
2
-
-
2242487094
-
Newly Developed Highly Sensitive LiF(Mg,Cu,P) TL Chips with High Signal-to-noise Ratio
-
Wang, S., Chen, G , Wu, F., Li, Y., Zha, Z. and Zhu, J. Newly Developed Highly Sensitive LiF(Mg,Cu,P) TL Chips with High Signal-to-noise Ratio. Radiat. Prot. Dosim 6, 350-352.
-
Radiat. Prot. Dosim
, vol.6
, pp. 350-352
-
-
Wang, S.1
Chen, G.2
Wu, F.3
Li, Y.4
Zha, Z.5
Zhu, J.6
-
3
-
-
0025010017
-
Characterisation of LiF:Mg,Cu,P (GR-200) for Personnel Thermoluminescence Dosimetry
-
Horowitz, Y. S. and Horowitz, A. Characterisation of LiF:Mg,Cu,P (GR-200) for Personnel Thermoluminescence Dosimetry. Radiat. Prot. Dosim. 33, 279-282 (1990).
-
(1990)
Radiat. Prot. Dosim.
, vol.33
, pp. 279-282
-
-
Horowitz, Y.S.1
Horowitz, A.2
-
4
-
-
0025155701
-
Influence of the Cooling Rate on Repeatability of LiF:Mg,Cu,P Thermoluminescence Chips
-
Piters, T. M. and Bos, A. J. J. Influence of the Cooling Rate on Repeatability of LiF:Mg,Cu,P Thermoluminescence Chips. Radiat. Prot. Dosim. 33, 91-94 (1990).
-
(1990)
Radiat. Prot. Dosim.
, vol.33
, pp. 91-94
-
-
Piters, T.M.1
Bos, A.J.J.2
-
5
-
-
2242437769
-
Study of the Kinetics Parameters in LiF:Mg,Cu,P
-
Bacci, C., Damilano, R., Furetta, C., Rispoli, B., Zhu, J., Cai, G. G., Delgado, A. and Gómez Ros, J. M. Study of the Kinetics Parameters in LiF:Mg,Cu,P. CIEMAT Report No. 717 (1990).
-
(1990)
CIEMAT Report No. 717
-
-
Bacci, C.1
Damilano, R.2
Furetta, C.3
Rispoli, B.4
Zhu, J.5
Cai, G.G.6
Delgado, A.7
Gómez Ros, J.M.8
-
6
-
-
0025475012
-
Isothermal Decay of Peak IV in LiF:Mg,Cu,P
-
Delgado, A., Gómez Ros, J. M., Bacci, C., Furetta, C. and Rispoli, B. Isothermal Decay of Peak IV in LiF:Mg,Cu,P. J. Phys. D: Appl. Phys. 23, 1132-1134 (1990).
-
(1990)
J. Phys. D: Appl. Phys.
, vol.23
, pp. 1132-1134
-
-
Delgado, A.1
Gómez Ros, J.M.2
Bacci, C.3
Furetta, C.4
Rispoli, B.5
-
7
-
-
0028963138
-
Intrinsic Self-Dosing and Long-term Stability and LiF TLD-100 and GR-200 TL Detectors
-
Delgado, A , Sáez-Vergara, J. C , Gómez Ros, J. M. and Romero, A. Intrinsic Self-Dosing and Long-term Stability and LiF TLD-100 and GR-200 TL Detectors. Radiat. Prot. Dosim. 58, 211-215 (1995).
-
(1995)
Radiat. Prot. Dosim.
, vol.58
, pp. 211-215
-
-
Delgado, A.1
Sáez-Vergara, J.C.2
Gómez Ros, J.M.3
Romero, A.4
-
8
-
-
0002428621
-
The Response of the New Hypersensitive Thermoluminescence Material to High Energy Photons (0.6-6 MeV)
-
Sáez-Vergara, J. C., Romero, A. M., Olko, P. and Budzanowski, M. The Response of the New Hypersensitive Thermoluminescence Material to High Energy Photons (0.6-6 MeV). Radiat. Prot Dosim 65(1-4), 167-172 (1996).
-
(1996)
Radiat. Prot Dosim
, vol.65
, Issue.1-4
, pp. 167-172
-
-
Sáez-Vergara, J.C.1
Romero, A.M.2
Olko, P.3
Budzanowski, M.4
-
9
-
-
0029163357
-
Computerized Analysis of LiF GR-200 TL Signal. Application to Dose Measurements in the μGy range
-
Delgado, A., Gómez Ros, J. M. and Muñiz J. L. Computerized Analysis of LiF GR-200 TL Signal. Application to Dose Measurements in the μGy range. Radiat. Prot. Dosim. 60(2), 147-153 (1995).
-
(1995)
Radiat. Prot. Dosim.
, vol.60
, Issue.2
, pp. 147-153
-
-
Delgado, A.1
Gómez Ros, J.M.2
Muñiz, J.L.3
-
10
-
-
0027730297
-
Glow Curve Readout of LiF:Mg,Cu,P (GR-200) Chips at Maximum Temperatures between 240°C and 280°C: Elimination of the Residual Signal
-
Oster, L., Horowitz, Y. S. and Horowitz, A. Glow Curve Readout of LiF:Mg,Cu,P (GR-200) Chips at Maximum Temperatures between 240°C and 280°C: Elimination of the Residual Signal. Radiat. Prot. Dosim. 49, 407-411 (1993).
-
(1993)
Radiat. Prot. Dosim.
, vol.49
, pp. 407-411
-
-
Oster, L.1
Horowitz, Y.S.2
Horowitz, A.3
-
11
-
-
2242420648
-
Ulteriori Studi sulle Carattersistiche Dosimetriche del LiF:Mg,Cu,P
-
Alghero, Italy
-
Scarpa, G., Moscati, M. and Soriani, A. Ulteriori Studi sulle Carattersistiche Dosimetriche del LiF:Mg,Cu,P. In: Proc. IV Symp. sulle Metodologie Radiometriche e Radiochimiche neall Radioprotezione. Alghero, Italy (1991).
-
(1991)
Proc. IV Symp. Sulle Metodologie Radiometriche e Radiochimiche Neall Radioprotezione
-
-
Scarpa, G.1
Moscati, M.2
Soriani, A.3
-
12
-
-
2242444970
-
Medidas de Dosis Absorbidas en el Rango del μGy con LiF:Mg,Cu,P (GR-200)
-
In Spanish, English available upon request
-
Delgado, A., Gómez Ros, J. M. and Muñiz, J. L. Medidas de Dosis Absorbidas en el Rango del μGy con LiF:Mg,Cu,P (GR-200). Radioprotección 1 (1994) (In Spanish, English available upon request.)
-
(1994)
Radioprotección
, vol.1
-
-
Delgado, A.1
Gómez Ros, J.M.2
Muñiz, J.L.3
-
13
-
-
2242435937
-
Sensitivity and Residual in LiF:Mg,Cu,P as a Function of Maximum Readout Temperature
-
Las Vegas, USA, in press
-
Rathbone, B. A. Sensitivity and Residual in LiF:Mg,Cu,P as a Function of Maximum Readout Temperature. In: Proc. Harshaw/Bicron TLD User's Symposium, Las Vegas, USA, 1995. (in press).
-
(1995)
Proc. Harshaw/Bicron TLD User's Symposium
-
-
Rathbone, B.A.1
-
14
-
-
0027240269
-
Preparation and Characteristics of LiF:Mg,Cu,P Thermoluminescent Material
-
Zha, Z., Wang S., Shen, W., Zhu, J. and Cai, G. Preparation and Characteristics of LiF:Mg,Cu,P Thermoluminescent Material. Radiat. Prot. Dosim. 47, 111-118 (1993).
-
(1993)
Radiat. Prot. Dosim.
, vol.47
, pp. 111-118
-
-
Zha, Z.1
Wang, S.2
Shen, W.3
Zhu, J.4
Cai, G.5
|