메뉴 건너뛰기




Volumn 21, Issue 2, 2001, Pages 133-139

Thermal sensor using the differential thermal analysis for the detection of relative humidity

Author keywords

Humidity; Sensors; Thermal analysis

Indexed keywords

ATMOSPHERIC HUMIDITY; CONDENSATION; DIFFERENTIAL THERMAL ANALYSIS; ELECTRIC POTENTIAL; SEEBECK EFFECT; THERMAL EFFECTS; THERMOCOUPLES; VAPORIZATION; WATER;

EID: 0035780476     PISSN: 02602288     EISSN: None     Source Type: Journal    
DOI: 10.1108/02602280110388333     Document Type: Article
Times cited : (1)

References (19)
  • 1
    • 0029322247 scopus 로고
    • New concept of integrated Peltier cooling device for the preventive detection of water condensation
    • Ancey, P., Gschwind, M. and Vancauwenberghe, O. (1995), "New concept of integrated Peltier cooling device for the preventive detection of water condensation", Sensors and Actuators, B26-27, pp. 303-07.
    • (1995) Sensors and Actuators , vol.B26-27 , pp. 303-307
    • Ancey, P.1    Gschwind, M.2    Vancauwenberghe, O.3
  • 2
    • 0026840184 scopus 로고
    • Properties of thin film thermoelectric materials: Application to sensors using the Seebeck effect
    • Boyer, A. and Cissé, E. (1992), "Properties of thin film thermoelectric materials: application to sensors using the Seebeck effect", Materials Science and Engineering, B13, pp. 103-11.
    • (1992) Materials Science and Engineering , vol.B13 , pp. 103-111
    • Boyer, A.1    Cissé, E.2
  • 3
    • 4244121220 scopus 로고    scopus 로고
    • Evolution de l'analyse calorimétrique différentielle (DSC)
    • October-November
    • Claudy, P. (1999), "Evolution de l'analyse calorimétrique différentielle (DSC)", Spectra Analyse, No. 210, October-November, pp. 17-22.
    • (1999) Spectra Analyse , Issue.210 , pp. 17-22
    • Claudy, P.1
  • 7
    • 0022320645 scopus 로고
    • A chilled mirror dew-point sensor/psychrometric transmitter for energy monitoring and control systems
    • Washington, DC, 15-18 April
    • Harding, J.C. (1985), "A chilled mirror dew-point sensor/psychrometric transmitter for energy monitoring and control systems", Proc. Moisture and Humidity Symp., Washington, DC, 15-18 April, pp. 491-504.
    • (1985) Proc. Moisture and Humidity Symp. , pp. 491-504
    • Harding, J.C.1
  • 8
    • 0029322749 scopus 로고
    • Surface acoustic wave (SAW) dew point sensor: Application to dew point hygrometer
    • Hoummady, M., Bonjour, C., Coillin, J., Lardet-Vieudrin, F. and Martin, G. (1995), "Surface acoustic wave (SAW) dew point sensor: application to dew point hygrometer", Sensors and Actuators, B26-27, pp. 315-17.
    • (1995) Sensors and Actuators , vol.B26-27 , pp. 315-317
    • Hoummady, M.1    Bonjour, C.2    Coillin, J.3    Lardet-Vieudrin, F.4    Martin, G.5
  • 9
    • 0026837418 scopus 로고
    • Dew point hygrometer with heat injection - Principle of construction and operation
    • Jachowicz, R.S. (1992), "Dew point hygrometer with heat injection - principle of construction and operation", Sensors and Actuators, B7, pp. 455-9.
    • (1992) Sensors and Actuators , vol.B7 , pp. 455-459
    • Jachowicz, R.S.1
  • 10
    • 0027647424 scopus 로고
    • Optimal measurement procedures for a dew point hygrometer system
    • Jachowicz, R.S. (1993), "Optimal measurement procedures for a dew point hygrometer system", IEEE Transactions on Instrumentation and Measurement, Vol 42 No. 4, pp. 828-33.
    • (1993) IEEE Transactions on Instrumentation and Measurement , vol.42 , Issue.4 , pp. 828-833
    • Jachowicz, R.S.1
  • 11
    • 0030182309 scopus 로고    scopus 로고
    • Absolute-humidity sensing independent of ambient temperature
    • Kimura, M. (1996), "Absolute-humidity sensing independent of ambient temperature", Sensors and Actuators, A55, pp. 7-11.
    • (1996) Sensors and Actuators , vol.A55 , pp. 7-11
    • Kimura, M.1
  • 12
    • 0011420603 scopus 로고    scopus 로고
    • Analyse thermique, tous les matériaux en profitent
    • Février
    • Le Parlouër, P. (2000), "Analyse thermique, tous les matériaux en profitent", Mesures, Vol. 722, Février, pp. 59-62.
    • (2000) Mesures , vol.722 , pp. 59-62
    • Le Parlouër, P.1
  • 13
    • 0029314112 scopus 로고
    • Air-flow sensor and humidity sensor application to neonatal infant respiration monitoring
    • Ma, Y., Ma, S., Wang, T. and Fang, W. (1995), "Air-flow sensor and humidity sensor application to neonatal infant respiration monitoring", Sensors and Actuators, A49, pp. 47-50.
    • (1995) Sensors and Actuators , vol.A49 , pp. 47-50
    • Ma, Y.1    Ma, S.2    Wang, T.3    Fang, W.4
  • 14
    • 0034275864 scopus 로고    scopus 로고
    • Quartz crystal microbalance (QCM) used as humidity sensor
    • Pascal-Delannoy, F., Sorli, B. and Boyer, A. (2000), "Quartz crystal microbalance (QCM) used as humidity sensor", Sensors and Actuators, Vol. 84, pp. 285-91.
    • (2000) Sensors and Actuators , vol.84 , pp. 285-291
    • Pascal-Delannoy, F.1    Sorli, B.2    Boyer, A.3
  • 17
    • 49149137630 scopus 로고
    • Solid-state humidity sensors
    • Regtien, P.P.L. (1981/1982), "Solid-state humidity sensors", Sensors and Actuators, Vol. 2, pp. 85-95.
    • (1981) Sensors and Actuators , vol.2 , pp. 85-95
    • Regtien, P.P.L.1
  • 19
    • 0011519715 scopus 로고    scopus 로고
    • Micro-module Peltier elaborated by flash technique and used as humidity sensor
    • Sorli, B., Foucaran, A., Pascal-Delannoy, F., Giani, A. and Boyer, A. (2000), "Micro-module Peltier elaborated by flash technique and used as humidity sensor", Sensor Review, Vol. 20 No. 4, pp. 332-5.
    • (2000) Sensor Review , vol.20 , Issue.4 , pp. 332-335
    • Sorli, B.1    Foucaran, A.2    Pascal-Delannoy, F.3    Giani, A.4    Boyer, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.