메뉴 건너뛰기




Volumn 65, Issue 2-3, 1998, Pages 165-170

Fast humidity sensor using optoelectronic detection on pulsed Peltier device

Author keywords

Humidity sensors; Intermittent detection; Peltier cooling devices

Indexed keywords

ATMOSPHERIC HUMIDITY; CONDENSATION; COOLING; PHOTODETECTORS; THERMOCOUPLES; THERMOELECTRIC EQUIPMENT;

EID: 0032520371     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0924-4247(97)01743-3     Document Type: Article
Times cited : (17)

References (11)
  • 1
    • 0022813956 scopus 로고
    • Humidity sensors: Principles and applications
    • N. Yamazoe, Y. Shimizu, Humidity sensors: principles and applications. Sensors and Actuators 10 (1986) 379-398.
    • (1986) Sensors and Actuators , vol.10 , pp. 379-398
    • Yamazoe, N.1    Shimizu, Y.2
  • 4
    • 0029314112 scopus 로고
    • Air flow sensor and humidity sensor application to neonatal infant respiration monitoring
    • Y. Ma, S. Ma, T. Wang, Air flow sensor and humidity sensor application to neonatal infant respiration monitoring, Sensors and Actuators A 49 (1995) 47-50.
    • (1995) Sensors and Actuators A , vol.49 , pp. 47-50
    • Ma, Y.1    Ma, S.2    Wang, T.3
  • 5
    • 49149137630 scopus 로고
    • Solid-state humidity sensors
    • P.P.L. Regtien, Solid-state humidity sensors, Sensors and Actuators 2 (1981) 85-95.
    • (1981) Sensors and Actuators , vol.2 , pp. 85-95
    • Regtien, P.P.L.1
  • 6
    • 0030182309 scopus 로고    scopus 로고
    • Absolute-humidity sensing independent of the ambient temperature
    • M. Kimura, Absolute-humidity sensing independent of the ambient temperature. Sensors and Actuators A 55 (1996) 7-11.
    • (1996) Sensors and Actuators A , vol.55 , pp. 7-11
    • Kimura, M.1
  • 7
    • 0026837418 scopus 로고
    • Dew point hygrometer with heat injection - Principle of construction and operation
    • R.S. Jachowicz, Dew point hygrometer with heat injection - principle of construction and operation, Sensors and Actuators B 7 (1992) 455-459.
    • (1992) Sensors and Actuators B , vol.7 , pp. 455-459
    • Jachowicz, R.S.1
  • 8
    • 0027647424 scopus 로고
    • Optimal measurement procedures for a dew point hygrometer system
    • R.S. Jachowicz, Optimal measurement procedures for a dew point hygrometer system, IEEE Trans. Instrum. Meas. 42 (1993) 828-814.
    • (1993) IEEE Trans. Instrum. Meas. , vol.42 , pp. 828-1814
    • Jachowicz, R.S.1
  • 9
    • 0029322247 scopus 로고
    • New concept of integrated Peltier cooling device for the preventive detection of water condensation
    • P. Ancey, M. Gschwind, O. Vancauwenberghe, New concept of integrated Peltier cooling device for the preventive detection of water condensation, Sensors and Actuators B 26-27 (1995) 303-305.
    • (1995) Sensors and Actuators B , vol.26-27 , pp. 303-305
    • Ancey, P.1    Gschwind, M.2    Vancauwenberghe, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.