메뉴 건너뛰기




Volumn 4560, Issue , 2001, Pages 207-216

Rapid fabrication of embossing tools for the production of polymeric microfluidic devices for bioanalytical applications

Author keywords

Embossing; LIGA; Microfluidics; Micromolding; PMMA; SU 8

Indexed keywords

DNA; ELECTROPHORESIS; NICKEL; POLYCARBONATES; POLYMERS; STAINLESS STEEL; X RAY LITHOGRAPHY;

EID: 0035766393     PISSN: 0277786X     EISSN: None     Source Type: Journal    
DOI: 10.1117/12.443060     Document Type: Article
Times cited : (9)

References (22)
  • 1
    • 0001739992 scopus 로고
    • Miniaturization of chemical-analysis systems - A look into next century technology or just a fashionable craze
    • A. Manz, D.J. Harrison, E.M.J. Verpoorte, J.C. Fettinger, H. Ludi, and H.M. Widmer, "Miniaturization of Chemical-Analysis Systems - a Look into Next Century Technology or Just a Fashionable Craze," Chimia, vol. 45, pp. 103-105, 1991.
    • (1991) Chimia , vol.45 , pp. 103-105
    • Manz, A.1    Harrison, D.J.2    Verpoorte, E.M.J.3    Fettinger, J.C.4    Ludi, H.5    Widmer, H.M.6
  • 3
    • 0028407532 scopus 로고
    • Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices
    • S.C. Jacobson, R. Hergenroder, L.B. Koutny, R.J. Warmack, and J.M. Ramsey, "Effects of Injection Schemes and Column Geometry on the Performance of Microchip Electrophoresis Devices," Analytical Chemistry, vol. 66, pp. 1107-1113, 1994.
    • (1994) Analytical Chemistry , vol.66 , pp. 1107-1113
    • Jacobson, S.C.1    Hergenroder, R.2    Koutny, L.B.3    Warmack, R.J.4    Ramsey, J.M.5
  • 6
    • 0031169963 scopus 로고    scopus 로고
    • UV laser machined polymer substrates for the development of microdiagnostic systems
    • M.A. Roberts, J.S. Rossier, P. Bercier, and H. Girault, "UV laser machined polymer substrates for the development of microdiagnostic systems," Analytical Chemistry, vol. 69, pp. 2035-2042, 1997.
    • (1997) Analytical Chemistry , vol.69 , pp. 2035-2042
    • Roberts, M.A.1    Rossier, J.S.2    Bercier, P.3    Girault, H.4
  • 7
    • 0033986278 scopus 로고    scopus 로고
    • Analysis of DNA fragments by microchip electrophoresis fabricated on poly(methyl methacrylate) substrates using a wire-imprinting method
    • Y.H. Chen and S.H. Chen, "Analysis of DNA fragments by microchip electrophoresis fabricated on poly(methyl methacrylate) substrates using a wire-imprinting method," Electrophoresis, vol. 21, pp. 165-170, 2000.
    • (2000) Electrophoresis , vol.21 , pp. 165-170
    • Chen, Y.H.1    Chen, S.H.2
  • 10
    • 0035971924 scopus 로고    scopus 로고
    • Microfabricated plastic chips by hot embossing methods and their applications for DNA separation and detection
    • G.B. Lee, S.H. Chen, G.R. Huang, W.C. Sung, and Y.H. Lin, "Microfabricated plastic chips by hot embossing methods and their applications for DNA separation and detection," Sensors and Actuators B-Chemical, vol. 75, pp. 142-148, 2001.
    • (2001) Sensors and Actuators B-Chemical , vol.75 , pp. 142-148
    • Lee, G.B.1    Chen, S.H.2    Huang, G.R.3    Sung, W.C.4    Lin, Y.H.5
  • 12
    • 0032768727 scopus 로고    scopus 로고
    • Nanoliter-scale sample preparation methods directly coupled to polymethylmethacrylate-based microchips and gel-filled capillaries for the analysis of oligonucleotides
    • S.A. Soper, S.M. Ford, Y.C. Xu, S.Z. Qi, S. McWhorter, S. Lassiter, D. Patterson, and R.C. Bruch, "Nanoliter-scale sample preparation methods directly coupled to polymethylmethacrylate-based microchips and gel-filled capillaries for the analysis of oligonucleotides," Journal of Chromatography A, vol. 853, pp. 107-120, 1999.
    • (1999) Journal of Chromatography A , vol.853 , pp. 107-120
    • Soper, S.A.1    Ford, S.M.2    Xu, Y.C.3    Qi, S.Z.4    McWhorter, S.5    Lassiter, S.6    Patterson, D.7    Bruch, R.C.8
  • 13
    • 0035041991 scopus 로고    scopus 로고
    • Plastic microchip electrophoresis for genetic screening: The analysis of polymerase chain reactions products of fragile X (CGG)n alleles
    • W.C. Sung, G.B. Lee, C.C. Tzeng, and S.H. Chen, "Plastic microchip electrophoresis for genetic screening: The analysis of polymerase chain reactions products of fragile X (CGG)n alleles," Electrophoresis, vol. 22, pp. 1188-1193, 2001.
    • (2001) Electrophoresis , vol.22 , pp. 1188-1193
    • Sung, W.C.1    Lee, G.B.2    Tzeng, C.C.3    Chen, S.H.4
  • 14
    • 0035805375 scopus 로고    scopus 로고
    • Isotachophoresis and isotachophoresis o zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection
    • R. Bodor, V. Madajova, D. Kaniansky, M. Masar, M. Johnck, and B. Stanislawski, "Isotachophoresis and isotachophoresis o zone electrophoresis separations of inorganic anions present in water samples on a planar chip with column-coupling separation channels and conductivity detection," Journal of Chromatography A, vol. 916, pp. 155-165,2001.
    • (2001) Journal of Chromatography A , vol.916 , pp. 155-165
    • Bodor, R.1    Madajova, V.2    Kaniansky, D.3    Masar, M.4    Johnck, M.5    Stanislawski, B.6
  • 15
    • 0035866596 scopus 로고    scopus 로고
    • Interfacing a polymer-based micromachined device to a nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometer
    • Z.J. Meng, S.Z. Qi, S.A. Soper, and P.A. Limbach, "Interfacing a polymer-based micromachined device to a nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometer," Analytical Chemistry, vol. 73, pp. 1286-1291, 2001.
    • (2001) Analytical Chemistry , vol.73 , pp. 1286-1291
    • Meng, Z.J.1    Qi, S.Z.2    Soper, S.A.3    Limbach, P.A.4
  • 17
    • 0035356152 scopus 로고    scopus 로고
    • Imaging of electroosmotic flow in plastic microchannels
    • D. Ross, T.J. Johnson, and L.E. Locascio, "Imaging of electroosmotic flow in plastic microchannels," Analytical Chemistry, vol. 73, pp. 2509-2515, 2001.
    • (2001) Analytical Chemistry , vol.73 , pp. 2509-2515
    • Ross, D.1    Johnson, T.J.2    Locascio, L.E.3
  • 19
    • 0033473707 scopus 로고    scopus 로고
    • Polymer hot embossing with silicon master structures
    • H. Becker and U. Helm, "Polymer hot embossing with silicon master structures," Sensors and Materials, vol. 11, pp. 297-304, 1999.
    • (1999) Sensors and Materials , vol.11 , pp. 297-304
    • Becker, H.1    Helm, U.2
  • 20
    • 0343550309 scopus 로고    scopus 로고
    • Polymer microfabrication methods for microfluidic analytical applications
    • H. Becker and C. Gartner, "Polymer microfabrication methods for microfluidic analytical applications," Electrophoresis, vol. 21, pp. 12-26, 2000.
    • (2000) Electrophoresis , vol.21 , pp. 12-26
    • Becker, H.1    Gartner, C.2
  • 22
    • 0033203927 scopus 로고    scopus 로고
    • Measurement of electroosmotic flow in plastic imprinted microfluid devices and the effect of protein adsorption on flow rate
    • L.E. Locascio, C.E. Perso, and C.S. Lee, "Measurement of electroosmotic flow in plastic imprinted microfluid devices and the effect of protein adsorption on flow rate," Journal of Chromatography A, vol. 857, pp. 275-284, 1999.
    • (1999) Journal of Chromatography A , vol.857 , pp. 275-284
    • Locascio, L.E.1    Perso, C.E.2    Lee, C.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.