-
1
-
-
0028186545
-
Guideline eleven: Guidelines for intraoperative monitoring of sensory evoked potentials
-
American Electroencephalographic Society: Guideline Eleven: Guidelines for intraoperative monitoring of sensory evoked potentials. J Clin Neurophysiol 11:77-87, 1994.
-
(1994)
J Clin Neurophysiol
, vol.11
, pp. 77-87
-
-
-
2
-
-
0024267556
-
The use of somatosensory evoked potentials in the evaluation of the central nervous system
-
Aminoff MJ: The use of somatosensory evoked potentials in the evaluation of the central nervous system. Neurol Clin 6:809-823, 1988.
-
(1988)
Neurol Clin
, vol.6
, pp. 809-823
-
-
Aminoff, M.J.1
-
3
-
-
0031747029
-
Simultaneous somatosensory evoked potential and electromyographic recordings during lumbosacral decompression and instrumentation
-
Balzer JR, Rose RD, Welch WC, et al: Simultaneous somatosensory evoked potential and electromyographic recordings during lumbosacral decompression and instrumentation. Neurosurg 42:1318-1324, 1998.
-
(1998)
Neurosurg
, vol.42
, pp. 1318-1324
-
-
Balzer, J.R.1
Rose, R.D.2
Welch, W.C.3
-
5
-
-
0031916644
-
"Threshold-level" multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: Description of method and comparison to somatosensory evoked potential monitoring
-
Calancie B, Harris W, Broton JG, et al: "Threshold-level" multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: Description of method and comparison to somatosensory evoked potential monitoring. J Neurosurg 88:457-470, 1998.
-
(1998)
J Neurosurg
, vol.88
, pp. 457-470
-
-
Calancie, B.1
Harris, W.2
Broton, J.G.3
-
6
-
-
0026738114
-
Intraoperative evoked EMG monitoring in an animal model: A new technique for evaluating pedicle screw placement
-
Calancie B, Nebwohl N, Madsen P: Intraoperative evoked EMG monitoring in an animal model: A new technique for evaluating pedicle screw placement. Spine 17:1229-1235, 1992.
-
(1992)
Spine
, vol.17
, pp. 1229-1235
-
-
Calancie, B.1
Nebwohl, N.2
Madsen, P.3
-
7
-
-
0028586882
-
Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation
-
Calancie B, Parley M, Lebwohl N: Stimulus-evoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Spine 19:2780-2786, 1994.
-
(1994)
Spine
, vol.19
, pp. 2780-2786
-
-
Calancie, B.1
Parley, M.2
Lebwohl, N.3
-
8
-
-
0029986628
-
Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement
-
Clements DH, Morledge DE, Martin WH, et al: Evoked and spontaneous electromyography to evaluate lumbosacral pedicle screw placement. Spine 21:600-604, 1996.
-
(1996)
Spine
, vol.21
, pp. 600-604
-
-
Clements, D.H.1
Morledge, D.E.2
Martin, W.H.3
-
9
-
-
0032518381
-
A comparison of impedance and electromyogram measurements in detecting the presence of pedicle wall breakthrough
-
Darden BV, Owen JH, Hatley MK, et al: A comparison of impedance and electromyogram measurements in detecting the presence of pedicle wall breakthrough. Spine 23:256-262, 1998.
-
(1998)
Spine
, vol.23
, pp. 256-262
-
-
Darden, B.V.1
Owen, J.H.2
Hatley, M.K.3
-
10
-
-
0029870260
-
Evaluation of pedicle screw insertion monitored by intraoperative evoked electromyography
-
Darden BV, Wood KE, Hatley MK, et al: Evaluation of pedicle screw insertion monitored by intraoperative evoked electromyography. J Spinal Disord 9:8-16, 1996.
-
(1996)
J Spinal Disord
, vol.9
, pp. 8-16
-
-
Darden, B.V.1
Wood, K.E.2
Hatley, M.K.3
-
11
-
-
0018657211
-
Intraoperative monitoring of facial muscle evoked responses obtained by intracranial stimulation of the facial nerve: A more accurate technique for facial nerve dissection
-
Delgado TE, Buchheit WA, Rosenholtz HR, et al: Intraoperative monitoring of facial muscle evoked responses obtained by intracranial stimulation of the facial nerve: A more accurate technique for facial nerve dissection. Neurosurg 4:418-421, 1979.
-
(1979)
Neurosurg
, vol.4
, pp. 418-421
-
-
Delgado, T.E.1
Buchheit, W.A.2
Rosenholtz, H.R.3
-
12
-
-
0022975930
-
Intraoperative spinal somatosensory evoked potential monitoring
-
Dinner DS, Luders H, Lesser RP, et al: Intraoperative spinal somatosensory evoked potential monitoring. J Neurosurg 65:807-814, 1986.
-
(1986)
J Neurosurg
, vol.65
, pp. 807-814
-
-
Dinner, D.S.1
Luders, H.2
Lesser, R.P.3
-
13
-
-
0018139277
-
Somatosensory evoked potentials during Harrington instrumentation for scoliosis
-
Engler GL, Spielholz NJ, Bernhard WN, et al: Somatosensory evoked potentials during Harrington instrumentation for scoliosis. J Bone Joint Surg 60A:528-532, 1978.
-
(1978)
J Bone Joint Surg
, vol.60 A
, pp. 528-532
-
-
Engler, G.L.1
Spielholz, N.J.2
Bernhard, W.N.3
-
14
-
-
0027189796
-
Evaluation of intraoperative somatosensory-evoked potential monitoring during 100 cervical operations
-
Epstein NE, Danto J, Nardi D: Evaluation of intraoperative somatosensory-evoked potential monitoring during 100 cervical operations. Spine 18:737-747, 1993.
-
(1993)
Spine
, vol.18
, pp. 737-747
-
-
Epstein, N.E.1
Danto, J.2
Nardi, D.3
-
15
-
-
0023685767
-
Evaluation of spinal cord function by means of lower limb somatosensory evoked potentials in reparative aortic surgery
-
Fava E, Bortolani EM, Ducati A, et al: Evaluation of spinal cord function by means of lower limb somatosensory evoked potentials in reparative aortic surgery. J Cardiovasc Surg 29:421-427, 1988.
-
(1988)
J Cardiovasc Surg
, vol.29
, pp. 421-427
-
-
Fava, E.1
Bortolani, E.M.2
Ducati, A.3
-
17
-
-
0029018888
-
A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation
-
Glassman SD, Dimar JR, Puno RM, et al: A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomographic scan confirmation. Spine 20:1375-1379, 1995.
-
(1995)
Spine
, vol.20
, pp. 1375-1379
-
-
Glassman, S.D.1
Dimar, J.R.2
Puno, R.M.3
-
18
-
-
0031607160
-
Minimizing spinal cord injury during repair of descending thoracic and thoracoabdominal aneurysms: The Mount Sinai approach
-
Griepp RB, Ergin MA, Galla JD, et al: Minimizing spinal cord injury during repair of descending thoracic and thoracoabdominal aneurysms: The Mount Sinai approach. Semin Thorac Cardiovasc Surg 10:25-28, 1998.
-
(1998)
Semin Thorac Cardiovasc Surg
, vol.10
, pp. 25-28
-
-
Griepp, R.B.1
Ergin, M.A.2
Galla, J.D.3
-
19
-
-
0030635527
-
Intraoperative monitoring of motor pathways during operative fixation of acute acetabular fractures
-
Helfet DL, Anand N, Malkani AL, et al: Intraoperative monitoring of motor pathways during operative fixation of acute acetabular fractures. J Orthop Trauma 11:2-6, 1997.
-
(1997)
J Orthop Trauma
, vol.11
, pp. 2-6
-
-
Helfet, D.L.1
Anand, N.2
Malkani, A.L.3
-
20
-
-
0030118109
-
Spine update: Spinal cord and nerve root monitoring in spine surgery and related procedures
-
Herdmann J, Deletis V, Edmonds HL, et al: Spine update: Spinal cord and nerve root monitoring in spine surgery and related procedures. Spine 21:879-885, 1996.
-
(1996)
Spine
, vol.21
, pp. 879-885
-
-
Herdmann, J.1
Deletis, V.2
Edmonds, H.L.3
-
21
-
-
0032168971
-
Intraoperative electromyography during thoracolumbar spinal surgery
-
Holland NR: Intraoperative electromyography during thoracolumbar spinal surgery. Spine 23:1915-1922, 1998.
-
(1998)
Spine
, vol.23
, pp. 1915-1922
-
-
Holland, N.R.1
-
22
-
-
0031410018
-
Continuous electromyographic monitoring to detect nerve root injury during thoracolumbar scoliosis surgery
-
Holland NR, Kostuik JP: Continuous electromyographic monitoring to detect nerve root injury during thoracolumbar scoliosis surgery. Spine 22:2547-2550, 1997.
-
(1997)
Spine
, vol.22
, pp. 2547-2550
-
-
Holland, N.R.1
Kostuik, J.P.2
-
23
-
-
0032518249
-
Higher electrical stimulus intensities are required to activate chronically compressed nerve roots
-
Holland NR, Lukaczyk TA, Riley LH, et al: Higher electrical stimulus intensities are required to activate chronically compressed nerve roots. Spine 23:234-227, 1998.
-
(1998)
Spine
, vol.23
, pp. 234-1227
-
-
Holland, N.R.1
Lukaczyk, T.A.2
Riley, L.H.3
-
24
-
-
0027524999
-
Monitoring of lumbosacral nerve roots during spinal instrumentation
-
Hormes JT, Chappius JL: Monitoring of lumbosacral nerve roots during spinal instrumentation. Spine 18:2059-2062, 1993.
-
(1993)
Spine
, vol.18
, pp. 2059-2062
-
-
Hormes, J.T.1
Chappius, J.L.2
-
25
-
-
0031008518
-
Recent advances in intraoperative neuromonitoring of spinal cord function: Pedicle screw stimulation techniques
-
Isley MR, Pearlman RC, Wadsworth JS: Recent advances in intraoperative neuromonitoring of spinal cord function: Pedicle screw stimulation techniques. Am J END Technol 37:93-126, 1997.
-
(1997)
Am J END Technol
, vol.37
, pp. 93-126
-
-
Isley, M.R.1
Pearlman, R.C.2
Wadsworth, J.S.3
-
27
-
-
0001616341
-
Experimental background: Signal analysis and behavioral correlates of evoked potential configurations in cats
-
John ER, Ruchkin DS, Villegas J: Experimental background: Signal analysis and behavioral correlates of evoked potential configurations in cats. Ann NY Acad Sci 112:362-420, 1964.
-
(1964)
Ann NY Acad Sci
, vol.112
, pp. 362-420
-
-
John, E.R.1
Ruchkin, D.S.2
Villegas, J.3
-
28
-
-
0022539711
-
Somatosensory evoked potential monitoring of spinal cord ischemia during aortic operations
-
Kaplan BJ, Friedman WA, Alexander MD, et al: Somatosensory evoked potential monitoring of spinal cord ischemia during aortic operations. Neurosurg 19:82-89, 1986.
-
(1986)
Neurosurg
, vol.19
, pp. 82-89
-
-
Kaplan, B.J.1
Friedman, W.A.2
Alexander, M.D.3
-
29
-
-
0024993129
-
Somatosensory cortical evoked potentials: A review of 100 cases of intraoperative spinal surgery monitoring
-
Keith RW, Stambough JL, Awender SH: Somatosensory cortical evoked potentials: A review of 100 cases of intraoperative spinal surgery monitoring. J Spinal Disord 3:220-226, 1990.
-
(1990)
J Spinal Disord
, vol.3
, pp. 220-226
-
-
Keith, R.W.1
Stambough, J.L.2
Awender, S.H.3
-
30
-
-
0031930294
-
Neurogenic motor evoked potentials: A prospective comparison of stimulation methods in spinal deformity surgery
-
Komanetsky RM, Padberg AM, Lenke LG, et al: Neurogenic motor evoked potentials: A prospective comparison of stimulation methods in spinal deformity surgery. J Spinal Disord 11:21-28, 1998.
-
(1998)
J Spinal Disord
, vol.11
, pp. 21-28
-
-
Komanetsky, R.M.1
Padberg, A.M.2
Lenke, L.G.3
-
31
-
-
0018966103
-
Evoked potentials in experimental myelopathy
-
Larson SJ, Walsh PR, Sances Jr A, et al: Evoked potentials in experimental myelopathy. Spine 5:299-302, 1980.
-
(1980)
Spine
, vol.5
, pp. 299-302
-
-
Larson, S.J.1
Walsh, P.R.2
Sances A., Jr.3
-
32
-
-
0023248856
-
Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. II. Use of somatosensory evoked potentials to assess adequacy of distal aortic bypass and perfusion after thoracic aortic cross-clamping
-
Laschinger JC, Cunningham JN, Baumann F, et al: Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. II. Use of somatosensory evoked potentials to assess adequacy of distal aortic bypass and perfusion after thoracic aortic cross-clamping. J Thorac Cardiovasc Surg 94:266-270, 1987.
-
(1987)
J Thorac Cardiovasc Surg
, vol.94
, pp. 266-270
-
-
Laschinger, J.C.1
Cunningham, J.N.2
Baumann, F.3
-
33
-
-
0020306666
-
Detection and prevention of intraoperative spinal cord ischemia after cross clamping of the thoracic aorta: Use of somatosensory evoked potentials
-
Laschinger JC, Cunningham Jr J, Catinella FP, et al: Detection and prevention of intraoperative spinal cord ischemia after cross clamping of the thoracic aorta: Use of somatosensory evoked potentials. Surgery 92:1109-1117, 1982.
-
(1982)
Surgery
, vol.92
, pp. 1109-1117
-
-
Laschinger, J.C.1
Cunningham J., Jr.2
Catinella, F.P.3
-
34
-
-
0023176531
-
Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. I. Relationship of aortic cross-clamp duration, changes in somatosensory evoked potentials, and incidence of neurologic dysfunction
-
Laschinger JC, Cunningham JN, Cooper MM, et al: Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. I. Relationship of aortic cross-clamp duration, changes in somatosensory evoked potentials, and incidence of neurologic dysfunction. J Thorac Cardiovasc Surg 94:260-265, 1987.
-
(1987)
J Thorac Cardiovasc Surg
, vol.94
, pp. 260-265
-
-
Laschinger, J.C.1
Cunningham, J.N.2
Cooper, M.M.3
-
35
-
-
0021035947
-
Definition of the safe lower limits of aortic resection during surgical procedures on the thoracoabdominal aorta: Use of somatosensory evoked potentials
-
Laschinger JC, Cunningham Jr J, Isom OW, et al: Definition of the safe lower limits of aortic resection during surgical procedures on the thoracoabdominal aorta: Use of somatosensory evoked potentials. J Am Coll Cardiol 2:959-965, 1983.
-
(1983)
J Am Coll Cardiol
, vol.2
, pp. 959-965
-
-
Laschinger, J.C.1
Cunningham J., Jr.2
Isom, O.W.3
-
36
-
-
0029093114
-
Triggered electromyographic threshold for accuracy of pedicle screw placement: An animal model and clinical correlation
-
Lenke LG, Padberg AM, Russo MH, et al: Triggered electromyographic threshold for accuracy of pedicle screw placement: An animal model and clinical correlation. Spine 20:1585-1591, 1995.
-
(1995)
Spine
, vol.20
, pp. 1585-1591
-
-
Lenke, L.G.1
Padberg, A.M.2
Russo, M.H.3
-
37
-
-
0039851979
-
New approach for diagnosis in herniated lumbosacral disc: Dermatomal somatosensory evoked potentials (DSSEPs)
-
Machida, Asai TM, Sato K, et al: New approach for diagnosis in herniated lumbosacral disc: Dermatomal somatosensory evoked potentials (DSSEPs). Spine 14:421-430, 1986.
-
(1986)
Spine
, vol.14
, pp. 421-430
-
-
Machida1
Asai, T.M.2
Sato, K.3
-
38
-
-
0028957058
-
Evaluation of intrapedicular screw position using intraoperative evoked electromyography
-
Maguire J, Wallace S, Madiga R, et al: Evaluation of intrapedicular screw position using intraoperative evoked electromyography. Spine 20:1068-1074, 1995.
-
(1995)
Spine
, vol.20
, pp. 1068-1074
-
-
Maguire, J.1
Wallace, S.2
Madiga, R.3
-
39
-
-
0030059348
-
Intraoperative SSEP monitoring during external fixation procedures in the lower extremities
-
Makarov MR, Delgado MR, Birch JG, et al: Intraoperative SSEP monitoring during external fixation procedures in the lower extremities. J Pediatr Orthop 16:155-160, 1996.
-
(1996)
J Pediatr Orthop
, vol.16
, pp. 155-160
-
-
Makarov, M.R.1
Delgado, M.R.2
Birch, J.G.3
-
40
-
-
0002405650
-
The collective electrical behavior of cortical neurons: The electroencephalogram and the mechanisms of epilepsy
-
Kandel ER, Schwartz JH, Jessell TM (eds). New York, Elsevier
-
Martin JH: The Collective Electrical Behavior of Cortical Neurons: The Electroencephalogram and the Mechanisms of Epilepsy. In Kandel ER, Schwartz JH, Jessell TM (eds). Principles of Neural Science. Ed 3. New York, Elsevier 777-791, 1991.
-
(1991)
Principles of Neural Science. Ed 3
, pp. 777-791
-
-
Martin, J.H.1
-
41
-
-
0029841262
-
Somatosensory evoked potential monitoring in cervical surgery: Identification of pre- and intraoperative risk factors associated with neurological deterioration
-
May DM, Jones SJ, Crockard HA: Somatosensory evoked potential monitoring in cervical surgery: Identification of pre- and intraoperative risk factors associated with neurological deterioration. J Neurosurg 85:566-573, 1996.
-
(1996)
J Neurosurg
, vol.85
, pp. 566-573
-
-
May, D.M.1
Jones, S.J.2
Crockard, H.A.3
-
42
-
-
0027721018
-
Issues surrounding spinal cord protection
-
Marini CP, Cunningham JN: Issues surrounding spinal cord protection. Adv Cardiac Surg 4:89-107, 1993.
-
(1993)
Adv Cardiac Surg
, vol.4
, pp. 89-107
-
-
Marini, C.P.1
Cunningham, J.N.2
-
43
-
-
0029976975
-
Intraoperative improvement of somatosensory evoked potentials and local spinal blood flow in patients with syringomyelia
-
Milhorat TH, Kotzen RM, Capocelli AL, et al: Intraoperative improvement of somatosensory evoked potentials and local spinal blood flow in patients with syringomyelia. J Neurosurg Anesth 8:208-215, 1996.
-
(1996)
J Neurosurg Anesth
, vol.8
, pp. 208-215
-
-
Milhorat, T.H.1
Kotzen, R.M.2
Capocelli, A.L.3
-
44
-
-
0031950288
-
Intraoperative monitoring with stimulus-evoked electromyography during placement of iliosacral screws: An initial clinical study
-
Moed BR, Ahmad BK, Craig JG, et al: Intraoperative monitoring with stimulus-evoked electromyography during placement of iliosacral screws: An initial clinical study. J Bone Joint Surg 80A:537-546, 1998.
-
(1998)
J Bone Joint Surg
, vol.80 A
, pp. 537-546
-
-
Moed, B.R.1
Ahmad, B.K.2
Craig, J.G.3
-
45
-
-
0021228195
-
Preservation of facial function during removal of acoustic neuromas: Use of monopolar constant-voltage stimulation and EMG
-
Møller AR, Jannetta PJ: Preservation of facial function during removal of acoustic neuromas: Use of monopolar constant-voltage stimulation and EMG. J Neurosurg 61:757-760, 1984.
-
(1984)
J Neurosurg
, vol.61
, pp. 757-760
-
-
Møller, A.R.1
Jannetta, P.J.2
-
46
-
-
0024207226
-
Use of somatosensory evoked potentials for intraoperative monitoring of cerebral and spinal cord function
-
Nuwer MR: Use of somatosensory evoked potentials for intraoperative monitoring of cerebral and spinal cord function. Neurol Clin 6:881-897, 1988.
-
(1988)
Neurol Clin
, vol.6
, pp. 881-897
-
-
Nuwer, M.R.1
-
47
-
-
0040444947
-
Somatosensory evoked potential spinal cord monitoring reduces neurological deficits after scoliosis surgery: Results of a large multicenter survey
-
Nuwer MR, Dawson EG, Carlson LG, et al: Somatosensory evoked potential spinal cord monitoring reduces neurological deficits after scoliosis surgery: Results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 87:263-273, 1995.
-
(1995)
Electroencephalogr Clin Neurophysiol
, vol.87
, pp. 263-273
-
-
Nuwer, M.R.1
Dawson, E.G.2
Carlson, L.G.3
-
48
-
-
0032808349
-
Mechanically elicited nerve root discharge: Mechanical irritation and waveform
-
Obi T, Mochizuki M, Isobe K, et al: Mechanically elicited nerve root discharge: Mechanical irritation and waveform. Acta Neurol Scand 100:185-188, 1999.
-
(1999)
Acta Neurol Scand
, vol.100
, pp. 185-188
-
-
Obi, T.1
Mochizuki, M.2
Isobe, K.3
-
49
-
-
0033572524
-
The application of intraoperative monitoring during surgery for spinal deformity
-
Owen JH: The application of intraoperative monitoring during surgery for spinal deformity. Spine 24:2649-2662, 1999.
-
(1999)
Spine
, vol.24
, pp. 2649-2662
-
-
Owen, J.H.1
-
50
-
-
0026199771
-
The clinical application of neurogenic motor evoked potentials to monitor spinal cord function during surgery
-
Owen JH, Bridwell KH, Grubb R, et al: The clinical application of neurogenic motor evoked potentials to monitor spinal cord function during surgery. Spine (Suppl) 16:385-390, 1991.
-
(1991)
Spine
, vol.16
, Issue.SUPPL.
, pp. 385-390
-
-
Owen, J.H.1
Bridwell, K.H.2
Grubb, R.3
-
51
-
-
0027168445
-
Innervation pattern of dorsal roots and their effects on the specificity of dermatomal somatosensory evoked potentials
-
Owen JH, Bridwell KH, Lenke L: Innervation pattern of dorsal roots and their effects on the specificity of dermatomal somatosensory evoked potentials. Spine 18:748-754, 1993.
-
(1993)
Spine
, vol.18
, pp. 748-754
-
-
Owen, J.H.1
Bridwell, K.H.2
Lenke, L.3
-
52
-
-
0028030049
-
The use of mechanically elicited electromyograms to protect nerve roots during surgery for spinal degeneration
-
Owen JH, Kostuik JP, Gornet M, et al: The use of mechanically elicited electromyograms to protect nerve roots during surgery for spinal degeneration. Spine 19:1704-1710, 1994.
-
(1994)
Spine
, vol.19
, pp. 1704-1710
-
-
Owen, J.H.1
Kostuik, J.P.2
Gornet, M.3
-
53
-
-
0025848784
-
Clinical correlation between degenerative spine diseases and dermatomal somatosensory evoked potentials in humans
-
Owen JH, Padberg AM, Spahr-Holland L, et al: Clinical correlation between degenerative spine diseases and dermatomal somatosensory evoked potentials in humans. Spine 16:S201-S205, 1991.
-
(1991)
Spine
, vol.16
-
-
Owen, J.H.1
Padberg, A.M.2
Spahr-Holland, L.3
-
54
-
-
0032796634
-
Spinal cord monitoring: Current state of the art
-
Padberg AM, Bridwell KH: Spinal cord monitoring: Current state of the art. Orthop Clin North Am 30:407-433, 1999.
-
(1999)
Orthop Clin North Am
, vol.30
, pp. 407-433
-
-
Padberg, A.M.1
Bridwell, K.H.2
-
55
-
-
0029997782
-
Validity and reliability of spinal cord monitoring in neuromuscular spinal deformity surgery
-
Padberg AM, Russo MH, Lenke LG, et al: Validity and reliability of spinal cord monitoring in neuromuscular spinal deformity surgery. J Spinal Disord 9:150-158, 1996.
-
(1996)
J Spinal Disord
, vol.9
, pp. 150-158
-
-
Padberg, A.M.1
Russo, M.H.2
Lenke, L.G.3
-
56
-
-
0032526343
-
Somatosensory- and motor-evoked potential monitoring without a wake-up test during idiopathic scoliosis surgery: An accepted standard of care
-
Padberg AM, Wilson-Holden TJ, Lenke LG, et al: Somatosensory- and motor-evoked potential monitoring without a wake-up test during idiopathic scoliosis surgery: An accepted standard of care. Spine 23:1392-1400, 1998.
-
(1998)
Spine
, vol.23
, pp. 1392-1400
-
-
Padberg, A.M.1
Wilson-Holden, T.J.2
Lenke, L.G.3
-
57
-
-
0029984237
-
Surgical maneuvers placing the sciatic nerve at risk during total hip arthroplasty as assessed by somatosensory evoked potential monitoring
-
Pereles TR, Stuchin SA, Kastenbaum DM, et al: Surgical maneuvers placing the sciatic nerve at risk during total hip arthroplasty as assessed by somatosensory evoked potential monitoring. J Arthroplasty 11:438-444, 1996.
-
(1996)
J Arthroplasty
, vol.11
, pp. 438-444
-
-
Pereles, T.R.1
Stuchin, S.A.2
Kastenbaum, D.M.3
-
58
-
-
0022551707
-
Acoustic (loudspeaker) facial electromyographic monitoring: Part 1. Evoked electromyographic activity during acoustic neuroma resection
-
Prass RL, Lüders H: Acoustic (loudspeaker) facial electromyographic monitoring: Part 1. Evoked electromyographic activity during acoustic neuroma resection. Neurosurg 19:392-400, 1986.
-
(1986)
Neurosurg
, vol.19
, pp. 392-400
-
-
Prass, R.L.1
Lüders, H.2
-
59
-
-
0031612248
-
Monitoring of somatosensory evoked potentials: A primer on the intraoperative detection of spinal cord ischemia during aortic reconstructive surgery
-
Robertazzi RR, Cunningham JN: Monitoring of somatosensory evoked potentials: A primer on the intraoperative detection of spinal cord ischemia during aortic reconstructive surgery. Semin Thorac Cardiovasc Surg 10:11-17, 1998.
-
(1998)
Semin Thorac Cardiovasc Surg
, vol.10
, pp. 11-17
-
-
Robertazzi, R.R.1
Cunningham, J.N.2
-
60
-
-
0005415220
-
Identification of the Sensorimotor Cortex with SSEP Phase Reversal
-
Loftus CM, Traynelis VC (eds). New York, McGraw Hill
-
Robertson SC, Traynelis VC, Yamada TT: Identification of the Sensorimotor Cortex with SSEP Phase Reversal. In Loftus CM, Traynelis VC (eds). Intraoperative Monitoring Techniques in Neurosurgery. New York, McGraw Hill 107-111, 1994.
-
(1994)
Intraoperative Monitoring Techniques in Neurosurgery
, pp. 107-111
-
-
Robertson, S.C.1
Traynelis, V.C.2
Yamada, T.T.3
-
61
-
-
0031045592
-
Persistently electrified pedicle stimulation instruments in spinal instrumentation
-
Rose RD, Welch WC, Balzer JR, et al: Persistently electrified pedicle stimulation instruments in spinal instrumentation. Spine 22:334-341, 1997.
-
(1997)
Spine
, vol.22
, pp. 334-341
-
-
Rose, R.D.1
Welch, W.C.2
Balzer, J.R.3
-
62
-
-
0025866007
-
Letter to the editor
-
Rosen CD: Letter to the editor. Spine 16:599, 1991.
-
(1991)
Spine
, vol.16
, pp. 599
-
-
Rosen, C.D.1
-
63
-
-
0040444945
-
Monitoring for aortic surgery
-
Simpson JM (ed). Newton, MA, Butterworth-Heinemann
-
Schulman SB, Weiss DS: Monitoring for Aortic Surgery. In Simpson JM (ed). Anesthesia for Aortic Surgery. Newton, MA, Butterworth-Heinemann 63-112, 1997.
-
(1997)
Anesthesia for Aortic Surgery
, pp. 63-112
-
-
Schulman, S.B.1
Weiss, D.S.2
-
64
-
-
0026537981
-
Dermatomal somatosensory evoked potentials: Cervical, thoracic, and lumbosacral levels
-
Slimp JC, Rubner DE, Snowden ML, et al: Dermatomal somatosensory evoked potentials: Cervical, thoracic, and lumbosacral levels. EEG Clin Neurophysiol 84:55-70, 1992.
-
(1992)
EEG Clin Neurophysiol
, vol.84
, pp. 55-70
-
-
Slimp, J.C.1
Rubner, D.E.2
Snowden, M.L.3
-
65
-
-
0029846992
-
Detection of stroke during cardiac operations with somatosensory evoked responses
-
Stecker MM, Cheung AT, Patterson T, et al: Detection of stroke during cardiac operations with somatosensory evoked responses. J Thorac Cardiovasc Surg 112:962-972, 1996.
-
(1996)
J Thorac Cardiovasc Surg
, vol.112
, pp. 962-972
-
-
Stecker, M.M.1
Cheung, A.T.2
Patterson, T.3
-
66
-
-
0029850650
-
Cotreldubousset instrumentation in children using simultaneous motor and somatosensory evoked potential monitoring
-
Stephen JP, Sullivan MR, Hicks RG, et al: Cotreldubousset instrumentation in children using simultaneous motor and somatosensory evoked potential monitoring. Spine 21:2450-2357, 1996.
-
(1996)
Spine
, vol.21
, pp. 2450-12357
-
-
Stephen, J.P.1
Sullivan, M.R.2
Hicks, R.G.3
-
67
-
-
0030039659
-
Use of spontaneous electromyography during revision and complex total hip arthroplasty
-
Sutherland CJ, Miller DH, Owen JH: Use of spontaneous electromyography during revision and complex total hip arthroplasty. J Arthroplasty 11:206-209, 1996.
-
(1996)
J Arthroplasty
, vol.11
, pp. 206-209
-
-
Sutherland, C.J.1
Miller, D.H.2
Owen, J.H.3
-
68
-
-
0031427841
-
Intraoperative dematomal evoked potential monitoring fails to predict outcome from lumbar decompression surgery
-
Tsai RY, Yang RS, Nuwer MR, et al: Intraoperative Dematomal evoked potential monitoring fails to predict outcome from lumbar decompression surgery. Spine 22:1970-1975, 1997.
-
(1997)
Spine
, vol.22
, pp. 1970-1975
-
-
Tsai, R.Y.1
Yang, R.S.2
Nuwer, M.R.3
-
69
-
-
0023127011
-
Monitoring of cortical evoked potentials during surgical procedures on the cervical spine
-
Veilleux M, Daube JR, Cucchiara RF: Monitoring of cortical evoked potentials during surgical procedures on the cervical spine. Mayo Clin Proc 62:256-264, 1987.
-
(1987)
Mayo Clin Proc
, vol.62
, pp. 256-264
-
-
Veilleux, M.1
Daube, J.R.2
Cucchiara, R.F.3
-
70
-
-
0030741966
-
Evaluation with evoked and spontaneous electromyography during lumbar instrumentation: A prospective study
-
Welch WC, Rose RD, Balzer JR, et al: Evaluation with evoked and spontaneous electromyography during lumbar instrumentation: A prospective study. J Neurosurg 87:397-402, 1997.
-
(1997)
J Neurosurg
, vol.87
, pp. 397-402
-
-
Welch, W.C.1
Rose, R.D.2
Balzer, J.R.3
-
71
-
-
0022496474
-
Recording of spinal somatosensory evoked potentials for intraoperative spinal cord monitoring
-
Whittle IR, Johnston IH, Besser M: Recording of spinal somatosensory evoked potentials for intraoperative spinal cord monitoring. J Neurosurg 64:601-612, 1986.
-
(1986)
J Neurosurg
, vol.64
, pp. 601-612
-
-
Whittle, I.R.1
Johnston, I.H.2
Besser, M.3
-
72
-
-
0032942387
-
The diagnostic value of dermatomal somatosensory evoked potentials in lumbosacral disc herniations: A critical approach
-
Yazicioglu K, Ozgul A, Kalyon TA, et al: The diagnostic value of dermatomal somatosensory evoked potentials in lumbosacral disc herniations: A critical approach. Electromyogr Clin Neurophysiol 39:175-181, 1999.
-
(1999)
Electromyogr Clin Neurophysiol
, vol.39
, pp. 175-181
-
-
Yazicioglu, K.1
Ozgul, A.2
Kalyon, T.A.3
|