-
1
-
-
0023626715
-
Stabilization of the lower thoracic and lumbar spine with the internal spinal skeletal fixation system: Indications, techniques, and first results of treatment
-
Aeba M, Etter C, Kehl X, Thalgott J: Stabilization of the lower thoracic and lumbar spine with the internal spinal skeletal fixation system: indications, techniques, and first results of treatment. Spine 12:546-551, 1987
-
(1987)
Spine
, vol.12
, pp. 546-551
-
-
Aeba, M.1
Etter, C.2
Kehl, X.3
Thalgott, J.4
-
2
-
-
33847466486
-
A method of spinal fusion
-
Boucher HH: A method of spinal fusion. J Bone Joint Surg [Br] 41:248-259, 1959
-
(1959)
J Bone Joint Surg [Br]
, vol.41
, pp. 248-259
-
-
Boucher, H.H.1
-
3
-
-
0021227205
-
Cortical evoked potential monitoring: A system for intraoperation monitoring of spinal cord function
-
Brown RH, Nash CL, Berilla JA, Amaddio MD: Cortical evoked potential monitoring: a system for intraoperation monitoring of spinal cord function. Spine 9:256-261, 1984
-
(1984)
Spine
, vol.9
, pp. 256-261
-
-
Brown, R.H.1
Nash, C.L.2
Berilla, J.A.3
Amaddio, M.D.4
-
4
-
-
0026738114
-
Intraoperative evoked EMG monitoring in an animal model: A new technique for evaluating pedicle screw placement
-
Calancie B, Lebwohl N, Madsen P, Klose KJ: Intraoperative evoked EMG monitoring in an animal model: a new technique for evaluating pedicle screw placement. Spine 17(10): 1229-1235, 1992
-
(1992)
Spine
, vol.17
, Issue.10
, pp. 1229-1235
-
-
Calancie, B.1
Lebwohl, N.2
Madsen, P.3
Klose, K.J.4
-
5
-
-
0023757068
-
Dermatomal monitoring for surgical correction of spondylolisthesis: A case report
-
Cohen BA, Huizenga BA: Dermatomal monitoring for surgical correction of spondylolisthesis: a case report. Spine 13: 1125-1128, 1988
-
(1988)
Spine
, vol.13
, pp. 1125-1128
-
-
Cohen, B.A.1
Huizenga, B.A.2
-
6
-
-
0026201632
-
Predictability of adequacy of spinal root decompression using evoked potentials
-
Cohen BA, Huizenga BA: Predictability of adequacy of spinal root decompression using evoked potentials. Spine 16:S379-S384, 1991
-
(1991)
Spine
, vol.16
-
-
Cohen, B.A.1
Huizenga, B.A.2
-
7
-
-
0022975930
-
Intraoperative spine somatosensory evoked potential monitoring
-
Dinner DS, Luders H, Lesser RP, et al.: Intraoperative spine somatosensory evoked potential monitoring. J Neurosurg 65:807-814, 1986
-
(1986)
J Neurosurg
, vol.65
, pp. 807-814
-
-
Dinner, D.S.1
Luders, H.2
Lesser, R.P.3
-
8
-
-
0024720172
-
Somatosensory evoked potentials in potentials in lumbar root decompression
-
Gepstein R, Brown MD: Somatosensory evoked potentials in potentials in lumbar root decompression. Clin Orthop 245: 69-71, 1989
-
(1989)
Clin Orthop
, vol.245
, pp. 69-71
-
-
Gepstein, R.1
Brown, M.D.2
-
9
-
-
0025267440
-
Accuracy of pedicular screw placement in vivo
-
Gertzbein SD, Robbins SE: Accuracy of pedicular screw placement in vivo. Spine 15:11-14, 1990
-
(1990)
Spine
, vol.15
, pp. 11-14
-
-
Gertzbein, S.D.1
Robbins, S.E.2
-
10
-
-
0020661303
-
Intraoperative monitoring of sensory-evoked potentials
-
Grndy BL: Intraoperative monitoring of sensory-evoked potentials. Anesthesiology 58:72-87, 1983
-
(1983)
Anesthesiology
, vol.58
, pp. 72-87
-
-
Grndy, B.L.1
-
11
-
-
0023258740
-
Intraoperative use of dermatomal somatosensory-evoked potentials in lumbar stenosis surgery
-
Herron LD, Trippi AC, Gonyeau M: Intraoperative use of dermatomal somatosensory-evoked potentials in lumbar stenosis surgery. Spine 12:379-383, 1987
-
(1987)
Spine
, vol.12
, pp. 379-383
-
-
Herron, L.D.1
Trippi, A.C.2
Gonyeau, M.3
-
12
-
-
0024513558
-
The Wiltse pedicle screw fixation system: Early clinical results
-
Horowitch A, Peek RD, Thomas JCJ, et al.: The Wiltse pedicle screw fixation system: early clinical results. Spine 14:461-467, 1989
-
(1989)
Spine
, vol.14
, pp. 461-467
-
-
Horowitch, A.1
Peek, R.D.2
Thomas, J.C.J.3
-
13
-
-
0022345020
-
Somatosensory evoked potentials as an aid in the diagnosis and intraoperative management of spinal stenosis
-
Keim HA, Hajdu M, Gonzalez EG, Brand L, Balasubramanian E: Somatosensory evoked potentials as an aid in the diagnosis and intraoperative management of spinal stenosis. Spine 10:338-344, 1985
-
(1985)
Spine
, vol.10
, pp. 338-344
-
-
Keim, H.A.1
Hajdu, M.2
Gonzalez, E.G.3
Brand, L.4
Balasubramanian, E.5
-
14
-
-
84938185804
-
Internal fixation for lumbosacral fusion
-
King D: Internal fixation for lumbosacral fusion. J Bone Joint Surg [Am] 30:560, 1948
-
(1948)
J Bone Joint Surg [Am]
, vol.30
, pp. 560
-
-
King, D.1
-
15
-
-
0002093074
-
Spinal instrumentation
-
ed by JN Weinstein, SW Wiesel. Philadelphia, WB Saunders
-
Krag MH, Fredrickson BE, Yuan HA: Spinal instrumentation. In: The lumbar spine, ed by JN Weinstein, SW Wiesel. Philadelphia, WB Saunders, 1990, pp 916-955
-
(1990)
The Lumbar Spine
, pp. 916-955
-
-
Krag, M.H.1
Fredrickson, B.E.2
Yuan, H.A.3
-
16
-
-
0024446555
-
Placement of transpedicular vertebral screws close to anterior vertebral cortex: Description of methods
-
Krag MH, Van Hal ME, Beynnon BD: Placement of transpedicular vertebral screws close to anterior vertebral cortex: description of methods. Spine 14:879-883, 1989
-
(1989)
Spine
, vol.14
, pp. 879-883
-
-
Krag, M.H.1
Van Hal, M.E.2
Beynnon, B.D.3
-
17
-
-
0022651507
-
Fusion of the lumbar and sacral spine by internal fixation with screws and plates
-
Louis R: Fusion of the lumbar and sacral spine by internal fixation with screws and plates. Clin Orthop 203:18-33, 1986
-
(1986)
Clin Orthop
, vol.203
, pp. 18-33
-
-
Louis, R.1
-
18
-
-
0025641159
-
Problems and solutions of pedicle screw plate fixation of lumbar spine
-
Matsuzaki H, Tokuhaski Y, Matsumoto F, et al.: Problems and solutions of pedicle screw plate fixation of lumbar spine. Spine 15:1159-1165, 1990
-
(1990)
Spine
, vol.15
, pp. 1159-1165
-
-
Matsuzaki, H.1
Tokuhaski, Y.2
Matsumoto, F.3
-
19
-
-
0024490714
-
Transpedicular screw fixation
-
Moran JM, Berg WS, Berry JL, Geiger JM, Steffee AD: Transpedicular screw fixation. J Orthop Res 7:107-114, 1989
-
(1989)
J Orthop Res
, vol.7
, pp. 107-114
-
-
Moran, J.M.1
Berg, W.S.2
Berry, J.L.3
Geiger, J.M.4
Steffee, A.D.5
-
20
-
-
0025848784
-
Clinical correlation between degenerative spine disease and dermatomal somatosensory-evoked potentials in humans
-
Owen JH, Padberg AM, Spahr-Hallond L, Bridwell KH, Keppler L, Steffee AD: Clinical correlation between degenerative spine disease and dermatomal somatosensory-evoked potentials in humans. Spine 16:S201-S205, 1991
-
(1991)
Spine
, vol.16
-
-
Owen, J.H.1
Padberg, A.M.2
Spahr-Hallond, L.3
Bridwell, K.H.4
Keppler, L.5
Steffee, A.D.6
-
21
-
-
0013770322
-
A method of spinal fusion using internal fixation
-
Pennal GF, McDonald GA, Dale GG: A method of spinal fusion using internal fixation. Clin Orthop 35:86-94, 1964
-
(1964)
Clin Orthop
, vol.35
, pp. 86-94
-
-
Pennal, G.F.1
McDonald, G.A.2
Dale, G.G.3
-
22
-
-
0025866007
-
Letter to the editor
-
Rosen CD: Letter to the editor. Spine 16:599, 1991
-
(1991)
Spine
, vol.16
, pp. 599
-
-
Rosen, C.D.1
-
23
-
-
0014806397
-
Osteosythese du rachis dorsal, lombaire et lumbosacre par plaques metalliques vissees dan les pedicules vertebraux et les apophyses articulaires
-
Roy-Camille R: Osteosythese du rachis dorsal, lombaire et lumbosacre par plaques metalliques vissees dan les pedicules vertebraux et les apophyses articulaires. Pred Med 78:1447, 1970
-
(1970)
Pred Med
, vol.78
, pp. 1447
-
-
Roy-Camille, R.1
-
24
-
-
0022625438
-
Internal fixation of the lumbar spine with pedicle screw plating
-
Roy-Camille R, Saillant G, Mazel C: Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop 203:7-17, 1986
-
(1986)
Clin Orthop
, vol.203
, pp. 7-17
-
-
Roy-Camille, R.1
Saillant, G.2
Mazel, C.3
-
25
-
-
0022642420
-
Segmental spine plates with pedicle screw fixation: A new internal fixation device for disorders of the lumbar and thoracolumbar spine
-
Steffee AD, Biscup RS, Sitkowski DJ: Segmental spine plates with pedicle screw fixation: a new internal fixation device for disorders of the lumbar and thoracolumbar spine. Clin Orthop 203:45-53, 1986
-
(1986)
Clin Orthop
, vol.203
, pp. 45-53
-
-
Steffee, A.D.1
Biscup, R.S.2
Sitkowski, D.J.3
-
26
-
-
0024555059
-
Reconstruction of the lumbar spine using AO DCP plate internal fixation
-
Thalgott JS, LaRocca H, Aebi M, Dwyer AP, Razz BE: Reconstruction of the lumbar spine using AO DCP plate internal fixation. Spine 14:91-95, 1989
-
(1989)
Spine
, vol.14
, pp. 91-95
-
-
Thalgott, J.S.1
LaRocca, H.2
Aebi, M.3
Dwyer, A.P.4
Razz, B.E.5
-
27
-
-
0026445667
-
Anatomic and technical considerations of pedicle screw fixation
-
Weinstein JN, Ryderik BL, Ravschning W: Anatomic and technical considerations of pedicle screw fixation. Clin Orthop 234:34-46, 1992
-
(1992)
Clin Orthop
, vol.234
, pp. 34-46
-
-
Weinstein, J.N.1
Ryderik, B.L.2
Ravschning, W.3
-
28
-
-
0023790873
-
Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
-
Weinstein JN, Spratt KF, Spendiger D, Brick C, Reid S: Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012-1018, 1988
-
(1988)
Spine
, vol.13
, pp. 1012-1018
-
-
Weinstein, J.N.1
Spratt, K.F.2
Spendiger, D.3
Brick, C.4
Reid, S.5
-
29
-
-
0026012523
-
Results of spinal arthrodesis with pedicle screw-plate fixation
-
West JL, Bradford DS, Ogilvie JW: Results of spinal arthrodesis with pedicle screw-plate fixation. J Bone Joint Surg [Am] 73:1179-1183, 1991
-
(1991)
J Bone Joint Surg [Am]
, vol.73
, pp. 1179-1183
-
-
West, J.L.1
Bradford, D.S.2
Ogilvie, J.W.3
-
30
-
-
0025879589
-
Complications of the variable screw plate pedicle screw fixation
-
West JL, Ogilvie JW, Bradford DS: Complications of the variable screw plate pedicle screw fixation. Screw 16:576-579, 1991
-
(1991)
Screw
, vol.16
, pp. 576-579
-
-
West, J.L.1
Ogilvie, J.W.2
Bradford, D.S.3
-
31
-
-
0024720461
-
Roentgenographic measurements of pedicle screw penetration
-
Whitecloud TS, Skalley TC, Cook SD, Morgan EL: Roentgenographic measurements of pedicle screw penetration. Clin Orthop 245:57-68, 1989
-
(1989)
Clin Orthop
, vol.245
, pp. 57-68
-
-
Whitecloud, T.S.1
Skalley, T.C.2
Cook, S.D.3
Morgan, E.L.4
-
32
-
-
0021705743
-
Postoperative neurological deficits in segmental spinal instrumentation
-
Wilber RG, Thompson GH, Shaffer JW, Brown RH, Nash CL: Postoperative neurological deficits in segmental spinal instrumentation. J Bone Joint Surg 66:1178-1187, 1984
-
(1984)
J Bone Joint Surg
, vol.66
, pp. 1178-1187
-
-
Wilber, R.G.1
Thompson, G.H.2
Shaffer, J.W.3
Brown, R.H.4
Nash, C.L.5
-
33
-
-
9244258089
-
Basic principles of neurophysiologic records in the operating room
-
ed by Kortush JM, Bouchard KR. New York, Raven Press
-
York D: Basic principles of neurophysiologic records in the operating room. In: Neuromonitoring in otology and head and neck surgery, ed by Kortush JM, Bouchard KR. New York, Raven Press, 1992, pp 15-16
-
(1992)
Neuromonitoring in Otology and Head and Neck Surgery
, pp. 15-16
-
-
York, D.1
-
34
-
-
0025762392
-
The role of transpedicular fixation systems for stabilization of the lumbar spine
-
Zindrick MR: The role of transpedicular fixation systems for stabilization of the lumbar spine. Orthop Clin North Am 22:333-343, 1991
-
(1991)
Orthop Clin North Am
, vol.22
, pp. 333-343
-
-
Zindrick, M.R.1
|