메뉴 건너뛰기




Volumn 23, Issue 12, 1998, Pages 1392-1400

Somatosensory- and motor-evoked potential monitoring without a wake-up test during idiopathic up test during idiopathic scoliosis surgery: An accepted standard of care

Author keywords

Idiopathic scoliosis; Neurogenic motor evoked potentials; Somatosensory evoked potentials; Stagnara wake up test

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EVOKED MUSCLE RESPONSE; EVOKED SOMATOSENSORY RESPONSE; HUMAN; IDIOPATHIC SCOLIOSIS; INHALATION ANESTHESIA; MAJOR CLINICAL STUDY; PRIORITY JOURNAL;

EID: 0032526343     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-199806150-00018     Document Type: Article
Times cited : (134)

References (27)
  • 1
    • 0023616030 scopus 로고
    • Posterior spinal fusion complicated by posterior column injury: A case report of a false-negative wake-up test
    • Ben-David B, Taylor PD, Haller GS. Posterior spinal fusion complicated by posterior column injury: A case report of a false-negative wake-up test. Spine 1987;12:540-3.
    • (1987) Spine , vol.12 , pp. 540-543
    • Ben-David, B.1    Taylor, P.D.2    Haller, G.S.3
  • 2
    • 0027536281 scopus 로고
    • Somatosensory evoked potential monitoring during Cotrel-Dubousset instrumentation
    • Booke JS, Banta JV, Bunke FJ, Pelletier C. Somatosensory evoked potential monitoring during Cotrel-Dubousset instrumentation. Spine 1993;18:518-21.
    • (1993) Spine , vol.18 , pp. 518-521
    • Booke, J.S.1    Banta, J.V.2    Bunke, F.J.3    Pelletier, C.4
  • 3
    • 0021231589 scopus 로고
    • Clinical evaluation of spinal cord monitoring in scoliosis surgery
    • Bradshaw K, Webb JK, Fraser AM. Clinical evaluation of spinal cord monitoring in scoliosis surgery. Spine 1984;6:636-43.
    • (1984) Spine , vol.6 , pp. 636-643
    • Bradshaw, K.1    Webb, J.K.2    Fraser, A.M.3
  • 4
    • 0021231589 scopus 로고
    • Clinical evaluation of spinal cord monitoring in scoliosis surgery
    • Bradshaw K, Webb JK, Fraser AM. Clinical evaluation of spinal cord monitoring in scoliosis surgery. Spine 1984;9:636-43.
    • (1984) Spine , vol.9 , pp. 636-643
    • Bradshaw, K.1    Webb, J.K.2    Fraser, A.M.3
  • 5
    • 0032006775 scopus 로고    scopus 로고
    • Major intraoperative neurologic deficits in pediatric and adult spinal deformity patients: Incidence and etiology at one institution
    • Bridwell KH, Lenke LG, Blades C, Blanke K. Major intraoperative neurologic deficits in pediatric and adult spinal deformity patients: Incidence and etiology at one institution. Spine, 1998;23:324-31.
    • (1998) Spine , vol.23 , pp. 324-331
    • Bridwell, K.H.1    Lenke, L.G.2    Blades, C.3    Blanke, K.4
  • 6
    • 0026201342 scopus 로고
    • Spinal cord monitoring: Results of the Scoliosis Research Society and the European Spinal Deformity Society survey
    • Dawson EG, Sherman JE, Kanim LEA, Nuwer MR. Spinal cord monitoring: Results of the Scoliosis Research Society and the European Spinal Deformity Society survey. Spine 1991; 16(Suppl):S361-4.
    • (1991) Spine , vol.16 , Issue.SUPPL.
    • Dawson, E.G.1    Sherman, J.E.2    Kanim, L.E.A.3    Nuwer, M.R.4
  • 7
    • 0021928016 scopus 로고
    • Postoperative paraplegia with preserved intraoperative somatosensory evoked potentials
    • Ginsberg HH, Shelter AG, Raudzess PA. Postoperative paraplegia with preserved intraoperative somatosensory evoked potentials. J Neurosurg 1985;63:296-300.
    • (1985) J Neurosurg , vol.63 , pp. 296-300
    • Ginsberg, H.H.1    Shelter, A.G.2    Raudzess, P.A.3
  • 8
    • 0031018822 scopus 로고    scopus 로고
    • The ankle clonus test for assessment of the integrity of the spinal cord during operations for scoliosis
    • Hoppenfeld S, Gross A, Andrews C, Lonner B. The ankle clonus test for assessment of the integrity of the spinal cord during operations for scoliosis. J Bone Joint Surg [Am] 1997; 79:208-12.
    • (1997) J Bone Joint Surg [Am] , vol.79 , pp. 208-212
    • Hoppenfeld, S.1    Gross, A.2    Andrews, C.3    Lonner, B.4
  • 9
    • 0000147667 scopus 로고
    • Report of committee on methods of clinical examination in EEG. Appendix: The ten-twenty electrode system of the International Federation
    • Jasper HH. Report of committee on methods of clinical examination in EEG. Appendix: The ten-twenty electrode system of the International Federation. Electroencephalogr Clin Neurophysiol 1958;10:371.
    • (1958) Electroencephalogr Clin Neurophysiol , vol.10 , pp. 371
    • Jasper, H.H.1
  • 10
    • 0008502458 scopus 로고
    • Criteria for detection and pathological significance of response decrement during spinal cord monitoring
    • Ducker T, Brown R, eds. New York: Springer-Verlag
    • Jones SJ, Howard L, Shawkat F. Criteria for detection and pathological significance of response decrement during spinal cord monitoring. In: Ducker T, Brown R, eds. Neurophysiology and standards of spinal cord monitoring. New York: Springer-Verlag, 1985:201-16.
    • (1985) Neurophysiology and Standards of Spinal Cord Monitoring , pp. 201-216
    • Jones, S.J.1    Howard, L.2    Shawkat, F.3
  • 11
    • 0027305709 scopus 로고
    • Use of sciatic neurogenic motor evoked potentials versus spinal potentials to predict early-onset neurologic deficits when intervention is still possible during overdistraction
    • Kai Y, Owen JH, Lenke LG, Bridwell KH, Oakley DM, Sugioka Y. Use of sciatic neurogenic motor evoked potentials versus spinal potentials to predict early-onset neurologic deficits when intervention is still possible during overdistraction. Spine 1993;18:1134-9.
    • (1993) Spine , vol.18 , pp. 1134-1139
    • Kai, Y.1    Owen, J.H.2    Lenke, L.G.3    Bridwell, K.H.4    Oakley, D.M.5    Sugioka, Y.6
  • 12
    • 31444437621 scopus 로고    scopus 로고
    • Intraoperative collision studies demonstrate descending spinal cord stimulated evoked potentials and ascending somatosensory evoked potentials are mediated through common pathways
    • May, Chicago, Illinois
    • Leppanen R, Madigan R, Sears C, Maguire J, Wallace S, Captain J. Intraoperative collision studies demonstrate descending spinal cord stimulated evoked potentials and ascending somatosensory evoked potentials are mediated through common pathways. Presented at the American Society of Neurophysiological Monitoring, Eighth annual meeting, May, 1997, Chicago, Illinois.
    • (1997) American Society of Neurophysiological Monitoring, Eighth Annual Meeting
    • Leppanen, R.1    Madigan, R.2    Sears, C.3    Maguire, J.4    Wallace, S.5    Captain, J.6
  • 13
    • 0022655150 scopus 로고
    • Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentials
    • Lesser RP, Raudzens P, Luders H, et al. Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentials. Ann Neurol 1986;19:22-5.
    • (1986) Ann Neurol , vol.19 , pp. 22-25
    • Lesser, R.P.1    Raudzens, P.2    Luders, H.3
  • 14
    • 0024459072 scopus 로고
    • Variability of somatosensory cortical evoked potential monitoring during spinal surgery
    • Lubicky JP, Spadaro JA, Yuan HA, Fredrickson BE, Henderson N. Variability of somatosensory cortical evoked potential monitoring during spinal surgery. Spine 1989;14:790-8.
    • (1989) Spine , vol.14 , pp. 790-798
    • Lubicky, J.P.1    Spadaro, J.A.2    Yuan, H.A.3    Fredrickson, B.E.4    Henderson, N.5
  • 15
    • 0016715026 scopus 로고
    • Acute neurological complications in the treatment of scoliosis: A report of the Scoliosis Research Society
    • MacEwen GD, Bunnel WP, Sriram K. Acute neurological complications in the treatment of scoliosis: A report of the Scoliosis Research Society. J Bone Joint Surg [Am] 1975;57: 404-8.
    • (1975) J Bone Joint Surg [Am] , vol.57 , pp. 404-408
    • MacEwen, G.D.1    Bunnel, W.P.2    Sriram, K.3
  • 16
    • 0022271221 scopus 로고
    • Spinal cord monitoring: Electrophysiological measures of sensory and motor function during spinal surgery
    • Machida M, Weinstein SL, Yameda T, Kimura J. Spinal cord monitoring: Electrophysiological measures of sensory and motor function during spinal surgery. Spine 1985;10:407-13.
    • (1985) Spine , vol.10 , pp. 407-413
    • Machida, M.1    Weinstein, S.L.2    Yameda, T.3    Kimura, J.4
  • 17
    • 0024654406 scopus 로고
    • Current concepts review: Spinal cord monitoring
    • Nash CL, Brown RH. Current concepts review: Spinal cord monitoring. J Bone Joint Surg [Am] 1989;71:627-30.
    • (1989) J Bone Joint Surg [Am] , vol.71 , pp. 627-630
    • Nash, C.L.1    Brown, R.H.2
  • 18
    • 0028881660 scopus 로고
    • Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter survey
    • Nuwer MR, Dawson EG, Carlson LG, Kanim LEA, Sherman JE. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: Results of a large multicenter survey. Electroencephalogr Clin Neurophysiol 1995;96:6-11.
    • (1995) Electroencephalogr Clin Neurophysiol , vol.96 , pp. 6-11
    • Nuwer, M.R.1    Dawson, E.G.2    Carlson, L.G.3    Kanim, L.E.A.4    Sherman, J.E.5
  • 19
    • 0026199771 scopus 로고
    • The clinical application of neurogenic motor evoked potentials to monitor spinal cord function during surgery
    • Owen JH, Bridwell KH, Grubb RL, et al. The clinical application of neurogenic motor evoked potentials to monitor spinal cord function during surgery. Spine 1991;7:385-90.
    • (1991) Spine , vol.7 , pp. 385-390
    • Owen, J.H.1    Bridwell, K.H.2    Grubb, R.L.3
  • 20
    • 0023698630 scopus 로고
    • Sensitivity and specificity of somatosensory and neurogenic-motor evoked potentials in animals and humans
    • Owen JH, Laschinger J, Bridwell KH, et al. Sensitivity and specificity of somatosensory and neurogenic-motor evoked potentials in animals and humans. Spine 1988;13:1111-8.
    • (1988) Spine , vol.13 , pp. 1111-1118
    • Owen, J.H.1    Laschinger, J.2    Bridwell, K.H.3
  • 21
    • 0024988896 scopus 로고
    • Relationship between duration of spinal cord ischemia and postoperative neurologic deficits in animals
    • Owen JH, Naito M, Bridwell KH, Oakley DM. Relationship between duration of spinal cord ischemia and postoperative neurologic deficits in animals. Spine 1990;15:846-51.
    • (1990) Spine , vol.15 , pp. 846-851
    • Owen, J.H.1    Naito, M.2    Bridwell, K.H.3    Oakley, D.M.4
  • 22
    • 0025081283 scopus 로고
    • Relationship among level of distraction, evoked potentials, spinal cord ischemia and integrity in clinical status and in animals
    • Owen JH, Naito M, Bridwell KH. Relationship among level of distraction, evoked potentials, spinal cord ischemia and integrity in clinical status and in animals. Spine 1990;15: 852-7.
    • (1990) Spine , vol.15 , pp. 852-857
    • Owen, J.H.1    Naito, M.2    Bridwell, K.H.3
  • 23
    • 0006134930 scopus 로고
    • Necessity of using somatosensory evoked potentials and motor evoked potentials to monitor spinal cord function during surgery for spinal deformity
    • Owen JH. Necessity of using somatosensory evoked potentials and motor evoked potentials to monitor spinal cord function during surgery for spinal deformity. American Society of Neurophysiologic Monitoring 1993;1:7-12.
    • (1993) American Society of Neurophysiologic Monitoring , vol.1 , pp. 7-12
    • Owen, J.H.1
  • 25
    • 0029850650 scopus 로고    scopus 로고
    • Cotrel-Dubousset instrumentation in children using simultaneous motor and somatosensory evoked potential monitoring
    • Stephen JP, Sullivan MR, Hicks RG, Burke DJ, Woodforth IJ, Crawford MR. Cotrel-Dubousset instrumentation in children using simultaneous motor and somatosensory evoked potential monitoring. Spine 1996;21:2450-7.
    • (1996) Spine , vol.21 , pp. 2450-2457
    • Stephen, J.P.1    Sullivan, M.R.2    Hicks, R.G.3    Burke, D.J.4    Woodforth, I.J.5    Crawford, M.R.6
  • 26
    • 0022601928 scopus 로고
    • Sensitivity of spinal cord monitoring to intraoperative events
    • Szalay EA, Carollo JJ, Roach JW. Sensitivity of spinal cord monitoring to intraoperative events. J Pediatr Orthop 1986;6: 437-41.
    • (1986) J Pediatr Orthop , vol.6 , pp. 437-441
    • Szalay, E.A.1    Carollo, J.J.2    Roach, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.