메뉴 건너뛰기




Volumn 11, Issue 3, 2000, Pages 147-162

Pulse sequences for interventional magnetic resonance imaging

Author keywords

Intervention; Magnetic resonance imaging; Pulse sequences

Indexed keywords

ARTICLE; DIAGNOSTIC IMAGING; DIAGNOSTIC PROCEDURE; FOURIER TRANSFORMATION; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; INTERVENTIONAL RADIOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PULSE WAVE; PULSED FIELD GEL ELECTROPHORESIS;

EID: 0034468402     PISSN: 08993459     EISSN: None     Source Type: Journal    
DOI: 10.1097/00002142-200006000-00001     Document Type: Article
Times cited : (17)

References (88)
  • 1
    • 0026563470 scopus 로고
    • The operating room of the future. Report of the National Cancer Institute Workshop. "Imaging-Guided stereotactic tumor diagnosis and treatment"
    • (1992) Invest Radiol , vol.27 , pp. 326-328
    • Jolesz, F.A.1    Shtern, F.2
  • 9
    • 0023733988 scopus 로고
    • Some factors that influence the steady state in steady-state free precession
    • (1988) Magn Reson Imaging , vol.6 , pp. 405-413
    • Patz, S.1
  • 10
    • 0025213880 scopus 로고
    • Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging
    • (1990) Magn Reson Med , vol.13 , pp. 77-89
    • Haase, A.1
  • 16
    • 0023705696 scopus 로고
    • The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences
    • (1988) Magn Reson Imaging , vol.6 , pp. 415-419
    • Gyngell, M.L.1
  • 21
    • 0032860009 scopus 로고    scopus 로고
    • Improved device definition using a rotated stripes keyhole acquisition in interventional magnetic resonance imaging (I-MRI)
    • (1999) Magn Reson Med , vol.42 , pp. 554-560
    • Hwang, K.P.1    Lim, J.2    Wendt, M.3
  • 43
    • 33746803555 scopus 로고
    • Image formation by induced local interactions: Examples employing nuclear magnetic resonance
    • (1973) Nature , vol.242 , pp. 190-191
    • Lauterbur, P.C.1
  • 81
    • 33744607266 scopus 로고
    • The proton-resonance-frequency-shift method compared with molecular diffusion for quantitative measurement of two-dimensional time-dependent temperature distribution in a phantom
    • (1994) J Magn Reson B , vol.103 , pp. 234-241
    • De Poorter, J.1    De Wagter, C.2    De Deene, Y.3
  • 83
    • 36849111386 scopus 로고
    • Proton resonance shift of water in the gas and liquid states
    • (1966) J Chem Phys , vol.44 , pp. 4582-4592
    • Hindman, J.C.1
  • 85
    • 0029112548 scopus 로고
    • Noninvasive MRI thermometry with the proton resonance frequency method: Study of susceptibility effects
    • (1995) Magn Reson Med , vol.34 , pp. 359-367
    • De Poorter, J.1
  • 87


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.