메뉴 건너뛰기




Volumn 67, Issue 3, 2000, Pages 244-253

Evaluating porous-layer open-tubular capillaries as vapor preconcentrators in a microanalytical system

Author keywords

[No Author keywords available]

Indexed keywords

ACOUSTIC SURFACE WAVE DEVICES; CAPILLARY FLOW; DESORPTION; OPEN CHANNEL FLOW; POROUS MATERIALS; SENSITIVITY ANALYSIS;

EID: 0034272767     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(00)00423-8     Document Type: Article
Times cited : (20)

References (39)
  • 3
    • 0023019419 scopus 로고
    • Detection of hazardous gases and vapors: Pattern recognition analysis of data from an electrochemical sensor array
    • Stetter J.R., Jurs P.C., Rose S.L. Detection of hazardous gases and vapors: pattern recognition analysis of data from an electrochemical sensor array. Anal. Chem. 58:1986;860-866.
    • (1986) Anal. Chem. , vol.58 , pp. 860-866
    • Stetter, J.R.1    Jurs, P.C.2    Rose, S.L.3
  • 4
    • 0033198573 scopus 로고    scopus 로고
    • Vapor recognition with small arrays of polymer-coated microsensors - A comprehensive analysis
    • Park J., Groves W.A., Zellers E.T. Vapor recognition with small arrays of polymer-coated microsensors - a comprehensive analysis. Anal. Chem. 71:1999;3877-3886.
    • (1999) Anal. Chem. , vol.71 , pp. 3877-3886
    • Park, J.1    Groves, W.A.2    Zellers, E.T.3
  • 5
    • 0034005594 scopus 로고    scopus 로고
    • Personal monitoring instrument for the selective measurement of multiple organic vapors
    • Park J., Zhang G.-Z., Zellers E.T. Personal monitoring instrument for the selective measurement of multiple organic vapors. Am. Ind. Hyg. Assoc. J. 61:2000;192-204.
    • (2000) Am. Ind. Hyg. Assoc. J. , vol.61 , pp. 192-204
    • Park, J.1    Zhang, G.-Z.2    Zellers, E.T.3
  • 6
    • 0033891559 scopus 로고    scopus 로고
    • Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors
    • Cai Q.Y., Park J., Heldsinger D., Hsieh M.D., Zellers E.T. Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors. Sens. Actuators B. 62:2000;121-130.
    • (2000) Sens. Actuators B , vol.62 , pp. 121-130
    • Cai, Q.Y.1    Park, J.2    Heldsinger, D.3    Hsieh, M.D.4    Zellers, E.T.5
  • 9
    • 0033104270 scopus 로고    scopus 로고
    • Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays
    • Grate J.W., Patrash S.J., Kaganove S.N., Wise B.M. Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays. Anal. Chem. 71:1999;1033-1040.
    • (1999) Anal. Chem. , vol.71 , pp. 1033-1040
    • Grate, J.W.1    Patrash, S.J.2    Kaganove, S.N.3    Wise, B.M.4
  • 10
    • 21844524304 scopus 로고
    • Environmental chemical sensing using quartz microbalance sensor arrays: Application of multicomponent analysis techniques
    • Hierlemann A., Weimar U., Kraus G., Gauglitz G. Environmental chemical sensing using quartz microbalance sensor arrays: application of multicomponent analysis techniques. Sens. Mater. 7:1995;179-189.
    • (1995) Sens. Mater. , vol.7 , pp. 179-189
    • Hierlemann, A.1    Weimar, U.2    Kraus, G.3    Gauglitz, G.4
  • 11
    • 0032487350 scopus 로고    scopus 로고
    • Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent
    • Groves W.A., Zellers E.T., Frye G.C. Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: selection and characterization of the preconcentrator adsorbent. Anal. Chim. Acta. 371(2-3):1998;131-143.
    • (1998) Anal. Chim. Acta , vol.371 , Issue.23 , pp. 131-143
    • Groves, W.A.1    Zellers, E.T.2    Frye, G.C.3
  • 12
    • 0000462297 scopus 로고
    • Smart sensor system for trace organophosphorus and organosulfur vapor detection employing acoustic wave sensors, automated sample preconcentration and pattern recognition
    • Grate J.W., Rose-Pehrsson S.L., Venezky D.L., Klusty M., Wohltjen H. Smart sensor system for trace organophosphorus and organosulfur vapor detection employing acoustic wave sensors, automated sample preconcentration and pattern recognition. Anal. Chem. 65:1993;1868-1881.
    • (1993) Anal. Chem. , vol.65 , pp. 1868-1881
    • Grate, J.W.1    Rose-Pehrsson, S.L.2    Venezky, D.L.3    Klusty, M.4    Wohltjen, H.5
  • 15
    • 0030459698 scopus 로고    scopus 로고
    • Prototype instrument employing an array of surface-acoustic-wave sensors for measuring organic vapors in exhaled breath
    • Groves W.A., Zellers E.T. Prototype instrument employing an array of surface-acoustic-wave sensors for measuring organic vapors in exhaled breath. Am. Ind. Hyg. Assoc. J. 57(12):1996;1103-1108.
    • (1996) Am. Ind. Hyg. Assoc. J. , vol.57 , Issue.12 , pp. 1103-1108
    • Groves, W.A.1    Zellers, E.T.2
  • 16
    • 2742610500 scopus 로고    scopus 로고
    • Multiway analysis of preconcentrator-sampled surface acoustic wave chemical sensor array data
    • Shaffer R.E., Rose-Pehrrson S.L., McGill R.A. Multiway analysis of preconcentrator-sampled surface acoustic wave chemical sensor array data. Field Anal. Chem. Technol. 2:1998;179-192.
    • (1998) Field Anal. Chem. Technol. , vol.2 , pp. 179-192
    • Shaffer, R.E.1    Rose-Pehrrson, S.L.2    McGill, R.A.3
  • 17
    • 0003126460 scopus 로고
    • Headspace gas analysis: The role and the design of concentration traps specifically suitable for capillary gas chromatography
    • Grob K., Habish A. Headspace gas analysis: the role and the design of concentration traps specifically suitable for capillary gas chromatography. J. Chrom. 321:1985;45-58.
    • (1985) J. Chrom. , vol.321 , pp. 45-58
    • Grob, K.1    Habish, A.2
  • 18
    • 0000133551 scopus 로고
    • Headspace gas analysis - quantitative trapping and thermal desorption of volatiles using fused-silica open tubular capillary traps
    • Burger B.V., Munro Z. Headspace gas analysis - quantitative trapping and thermal desorption of volatiles using fused-silica open tubular capillary traps. J. Chrom. 370:1986;449-464.
    • (1986) J. Chrom. , vol.370 , pp. 449-464
    • Burger, B.V.1    Munro, Z.2
  • 19
    • 0345791663 scopus 로고    scopus 로고
    • Trace analysis of semi-volatile organic air pollutants using thick-film silicone rubber traps with capillary gas chromatography
    • Ortner E.K., Rohwer E.R. Trace analysis of semi-volatile organic air pollutants using thick-film silicone rubber traps with capillary gas chromatography. HRC J. High Resolut. Chrom. 19:1996;339-344.
    • (1996) HRC J. High Resolut. Chrom. , vol.19 , pp. 339-344
    • Ortner, E.K.1    Rohwer, E.R.2
  • 20
    • 84985294672 scopus 로고
    • Headspace gas analysis: Comparison of the efficiency of thick film, ultra thick film and activated charcoal open tubular capillary traps for the concentration of volatile airborne organic compounds
    • Burger B.V., le Roux M. Headspace gas analysis: comparison of the efficiency of thick film, ultra thick film and activated charcoal open tubular capillary traps for the concentration of volatile airborne organic compounds. J. High Resolut. Chrom. 15:1992;373-376.
    • (1992) J. High Resolut. Chrom. , vol.15 , pp. 373-376
    • Burger, B.V.1    Le Roux, M.2
  • 21
    • 0347683496 scopus 로고    scopus 로고
    • A new method for sorptive enrichment of gaseous samples: Application in air analysis and natural gas characterization
    • Baltussen E., Janssen H.G., Sandra P., Cramers C.A. A new method for sorptive enrichment of gaseous samples: application in air analysis and natural gas characterization. HRC J. High Resolut. Chrom. 20:1997;385-393.
    • (1997) HRC J. High Resolut. Chrom. , vol.20 , pp. 385-393
    • Baltussen, E.1    Janssen, H.G.2    Sandra, P.3    Cramers, C.A.4
  • 24
    • 0001714219 scopus 로고
    • Performance of fixed-bed catalytic reactors with poison in the feed
    • Wheeler A., Robell A.J. Performance of fixed-bed catalytic reactors with poison in the feed. J. Catal. 13:1969;299-305.
    • (1969) J. Catal. , vol.13 , pp. 299-305
    • Wheeler, A.1    Robell, A.J.2
  • 25
    • 0000600338 scopus 로고
    • The kinetics of adsorption of carbon tetrachloride and chloroform from air mixtures by activated carbon
    • Jonas L.A., Svirbely W.J. The kinetics of adsorption of carbon tetrachloride and chloroform from air mixtures by activated carbon. J. Catal. 24:1972;446-459.
    • (1972) J. Catal. , vol.24 , pp. 446-459
    • Jonas, L.A.1    Svirbely, W.J.2
  • 26
    • 0015474455 scopus 로고
    • The kinetics of adsorption of organophosphorus vapors from air mixtures by activated carbon
    • Jonas L.A., Rehrmann J.A. The kinetics of adsorption of organophosphorus vapors from air mixtures by activated carbon. Carbon. 10:1972;657-663.
    • (1972) Carbon , vol.10 , pp. 657-663
    • Jonas, L.A.1    Rehrmann, J.A.2
  • 27
    • 0021282154 scopus 로고
    • Applications of gas adsorption kinetics I. A theoretical model for respirator cartridge service life
    • Yoon Y.H., Nelson J.H. Applications of gas adsorption kinetics I. A theoretical model for respirator cartridge service life. Am. Ind. Hyg. Assoc. J. 45:1984;509-516.
    • (1984) Am. Ind. Hyg. Assoc. J. , vol.45 , pp. 509-516
    • Yoon, Y.H.1    Nelson, J.H.2
  • 28
    • 0024445790 scopus 로고
    • A review of the Wheeler Equation and comparison of its applications to organic vapor respirator cartridge breakthrough data
    • Wood G.O., Moyer E.S. A review of the Wheeler Equation and comparison of its applications to organic vapor respirator cartridge breakthrough data. Am. Ind. Hyg. Assoc. J. 50:1989;400-407.
    • (1989) Am. Ind. Hyg. Assoc. J. , vol.50 , pp. 400-407
    • Wood, G.O.1    Moyer, E.S.2
  • 31
    • 33845752102 scopus 로고
    • American Chemical Society, Washington, DC
    • Beilstein Online Database, American Chemical Society, Washington, DC, 1990.
    • (1990) Beilstein Online Database
  • 34
    • 0024289506 scopus 로고
    • Determination of hazardous vapors including mixtures using pattern recognition analysis of responses from surface acoustic wave devices
    • Rose-Pehrrson S.L., Grate J.W., Ballantine D.S. Jr., Jurs P. Determination of hazardous vapors including mixtures using pattern recognition analysis of responses from surface acoustic wave devices. Anal. Chem. 60:1988;2801-2811.
    • (1988) Anal. Chem. , vol.60 , pp. 2801-2811
    • Rose-Pehrrson, S.L.1    Grate, J.W.2    Ballantine D.S., Jr.3    Jurs, P.4
  • 35
    • 0016279015 scopus 로고
    • Respirator cartridge efficiency studies V. Effects of solvent vapor
    • Nelson G.O., Harder C.A. Respirator cartridge efficiency studies V. Effects of solvent vapor. Am. Indust. Hyg. Assoc. J. 35:1974;391-410.
    • (1974) Am. Indust. Hyg. Assoc. J. , vol.35 , pp. 391-410
    • Nelson, G.O.1    Harder, C.A.2
  • 37
    • 0022159085 scopus 로고
    • Residence time model for respirator sorbent beds
    • Ackley M.W. Residence time model for respirator sorbent beds. Am. Indust. Hyg. Assoc. J. 46:1985;679-689.
    • (1985) Am. Indust. Hyg. Assoc. J. , vol.46 , pp. 679-689
    • Ackley, M.W.1
  • 38
    • 0027645276 scopus 로고
    • Characterization of polymeric surface-acoustic-wave sensor coatings and semi-empirical models of sensor responses to organic vapors
    • Patrash S.J., Zellers E.T. Characterization of polymeric surface-acoustic-wave sensor coatings and semi-empirical models of sensor responses to organic vapors. Anal. Chem. 65:1993;2055-2066.
    • (1993) Anal. Chem. , vol.65 , pp. 2055-2066
    • Patrash, S.J.1    Zellers, E.T.2
  • 39
    • 0030181263 scopus 로고    scopus 로고
    • Effects of temperature and ambient humidity on the performance of polymer-coated surface acoustic wave vapor sensor arrays
    • Zellers E.T., Han M. Effects of temperature and ambient humidity on the performance of polymer-coated surface acoustic wave vapor sensor arrays. Anal. Chem. 68:1996;2409-2418.
    • (1996) Anal. Chem. , vol.68 , pp. 2409-2418
    • Zellers, E.T.1    Han, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.