Volumn 2, Issue 3, 1998, Pages 179-192

Multiway Analysis of Preconcentrator-Sampled Surface Acoustic Wave Chemical Sensor Array Data

Author keywords

Chemical sensor; Chemometrics; Nerve agent; Pattern recognition; Preconcentration; Surface acoustic wave

Indexed keywords


EID: 2742610500     PISSN: 1086900X     EISSN: None     Source Type: Journal    
DOI: 10.1002/(sici)1520-6521(1998)2:3<179::aid-fact7>3.0.co;2-q     Document Type: Article
Times cited : (24)

References (20)
  • 1
    • 33845184712 scopus 로고
    • Surface Acoustic Wave Devices for Chemical Analysis
    • D. S. Ballantine and H. Wohltjen, "Surface Acoustic Wave Devices for Chemical Analysis", Anal Chem. 11, 704A-715A, (1989).
    • (1989) Anal Chem. , vol.11
    • Ballantine, D.S.1    Wohltjen, H.2
  • 2
    • 0028513983 scopus 로고
    • Choosing Polymer Coatings for Chemical Sensors
    • R. A. McGill, M. H. Abraham and J. W. Grate, "Choosing Polymer Coatings for Chemical Sensors", Chemtech 24, 27-37, (1994).
    • (1994) Chemtech , vol.24 , pp. 27-37
    • McGill, R.A.1    Abraham, M.H.2    Grate, J.W.3
  • 3
    • 0000462297 scopus 로고
    • Smart Sensor System for Trace Organophosphorus and Organosulfur Vapor Detection Employing a Temperature-Controlled Array of Surface Acoustic Wave Sensors, Automated Sample Preconcentration, and Pattern Recognition
    • J. W. Grate, S. L. Rose-Pehrsson, D. L. Venezky, M. Klusty and H. Wohltjen, "Smart Sensor System for Trace Organophosphorus and Organosulfur Vapor Detection Employing a Temperature-Controlled Array of Surface Acoustic Wave Sensors, Automated Sample Preconcentration, and Pattern Recognition," Anal Chem. 65, 1868-1881, (1993).
    • (1993) Anal Chem. , vol.65 , pp. 1868-1881
    • Grate, J.W.1    Rose-Pehrsson, S.L.2    Venezky, D.L.3    Klusty, M.4    Wohltjen, H.5
  • 6
    • 0030181263 scopus 로고    scopus 로고
    • Effects of Temperature and Humidity on the Performance of Polymer-Coated Surface Acoustic Wave Vapor Sensor Arrays
    • E. T. Zellers and M. Han, "Effects of Temperature and Humidity on the Performance of Polymer-Coated Surface Acoustic Wave Vapor Sensor Arrays," Anal. Chem. 68, 2409-2418, (1996).
    • (1996) Anal. Chem. , vol.68 , pp. 2409-2418
    • Zellers, E.T.1    Han, M.2
  • 7
    • 18944397868 scopus 로고
    • Theory of Analytical Chemistry
    • K. S. Booksh and B. R. Kowalski, "Theory of Analytical Chemistry," Anal. Chem. 66, 782A-791A, (1994).
    • (1994) Anal. Chem. , vol.66
    • Booksh, K.S.1    Kowalski, B.R.2
  • 8
    • 0010040681 scopus 로고
    • Multi-Way Principal Components and PLS Analysis
    • S. Wold, P. Geladi, K. Esbensen and J. Ohman, "Multi-Way Principal Components and PLS Analysis," J. Chemometrics 1, 41-56, (1987).
    • (1987) J. Chemometrics , vol.1 , pp. 41-56
    • Wold, S.1    Geladi, P.2    Esbensen, K.3    Ohman, J.4
  • 9
    • 0024847384 scopus 로고
    • Analysis of Multi-Way (Multi-Mode) Data
    • P. Geladi, "Analysis of Multi-Way (Multi-Mode) Data," Chemometrics Intell. Lab. Syst. 7, 11-30, (1989).
    • (1989) Chemometrics Intell. Lab. Syst. , vol.7 , pp. 11-30
    • Geladi, P.1
  • 10
    • 0003009442 scopus 로고    scopus 로고
    • Multiway Calibration. Multilinear PLS
    • R. Bro, "Multiway Calibration. Multilinear PLS," J. Chemometrics 10, 47-61 (1996).
    • (1996) J. Chemometrics , vol.10 , pp. 47-61
    • Bro1
  • 11
    • 2742561680 scopus 로고    scopus 로고
    • Design & Evaluation of SAWCAD Performance Part 1: Field Tests in South Korea 3rd-7th November 1994
    • in preparation
    • R. A. McGill, C. Chon and D. L. Venezky, "Design & Evaluation of SAWCAD Performance Part 1: Field Tests in South Korea 3rd-7th November 1994," Naval Research Laboratory Memorandum Report, in preparation.
    • Naval Research Laboratory Memorandum Report
    • McGill, R.A.1    Chon, C.2    Venezky, D.L.3
  • 12
    • 2742562787 scopus 로고    scopus 로고
    • Design & Evaluation of SAWCAD Performance Part 2: Chemical Agent Test & Evaluation
    • in preparation
    • R. A. McGill et al., "Design & Evaluation of SAWCAD Performance Part 2: Chemical Agent Test & Evaluation," Naval Research Laboratory Memorandum Report, in preparation.
    • Naval Research Laboratory Memorandum Report
    • McGill, R.A.1
  • 13
    • 0026104208 scopus 로고
    • Solubility Interactions and the Design of Chemically Selective Sorbent Coatings for Chemical Sensors and Arrays
    • J. W. Grate and M. H. Abraham, "Solubility Interactions and the Design of Chemically Selective Sorbent Coatings for Chemical Sensors and Arrays," Sensors Actuators B 3, 85-111, (1991).
    • (1991) Sensors Actuators B , vol.3 , pp. 85-111
    • Grate, J.W.1    Abraham, M.H.2
  • 18
    • 0029888347 scopus 로고    scopus 로고
    • Discriminant Analysis of High-Dimensional Data: A Comparison of Principal Components Analysis and Partial Least Squares Data Reduction Methods
    • E. K. Kemsley, "Discriminant Analysis of High-Dimensional Data: A Comparison of Principal Components Analysis and Partial Least Squares Data Reduction Methods, Chemometrics Intell. Lab. Syst. 33, 47-61, (1996).
    • (1996) Chemometrics Intell. Lab. Syst. , vol.33 , pp. 47-61
    • Kemsley, E.K.1
  • 19
    • 2742559522 scopus 로고    scopus 로고
    • http://newton.foodsci.kvl.dk/foodtech
  • 20
    • 0030595360 scopus 로고    scopus 로고
    • Feature Reduction by Fourier Transform in Pattern Recognition of NIR Data
    • W. Wu, B. Walzak, W. Penninckx and D. L. Massart, "Feature Reduction by Fourier Transform in Pattern Recognition of NIR Data," Analyt. Chim. Acta 331, 75-83, (1996).
    • (1996) Analyt. Chim. Acta , vol.331 , pp. 75-83
    • Wu, W.1    Walzak, B.2    Penninckx, W.3    Massart, D.L.4