메뉴 건너뛰기




Volumn 62, Issue 2, 2000, Pages 121-130

Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors

Author keywords

[No Author keywords available]

Indexed keywords

MATHEMATICAL MODELS; MIXTURES; MONTE CARLO METHODS; PATTERN RECOGNITION; VAPORS;

EID: 0033891559     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(99)00381-0     Document Type: Article
Times cited : (73)

References (27)
  • 1
    • 0029644463 scopus 로고
    • Optimal coating selection for the analysis of organic vapor mixtures with polymer-coated surface acoustic wave sensor arrays
    • Zellers E.T., Batterman S., Han M., Patrash S.J. Optimal coating selection for the analysis of organic vapor mixtures with polymer-coated surface acoustic wave sensor arrays. Anal. Chem. 67:1995;1092-1106.
    • (1995) Anal. Chem. , vol.67 , pp. 1092-1106
    • Zellers, E.T.1    Batterman, S.2    Han, M.3    Patrash, S.J.4
  • 2
    • 0034005594 scopus 로고    scopus 로고
    • Personal monitoring instrument for the selective measurement of multiple organic vapors
    • in press
    • J. Park, G.-Z. Zhang, E.T. Zellers, Personal monitoring instrument for the selective measurement of multiple organic vapors, Am. Ind. Hyg. Assoc. J. (2000) in press.
    • (2000) Am. Ind. Hyg. Assoc. J.
    • Park, J.1    Zhang, G.-Z.2    Zellers, E.T.3
  • 3
    • 0033198573 scopus 로고    scopus 로고
    • Vapor recognition with small arrays of polymer-coated microsensors - A comprehensive analysis
    • Park J., Groves W.A., Zellers E.T. Vapor recognition with small arrays of polymer-coated microsensors - a comprehensive analysis. Anal. Chem. 71:1999;3877-3886.
    • (1999) Anal. Chem. , vol.71 , pp. 3877-3886
    • Park, J.1    Groves, W.A.2    Zellers, E.T.3
  • 5
    • 0001111112 scopus 로고    scopus 로고
    • Surface acoustic wave chemical sensor arrays: New chemically sensitive interfaces combined with novel cluster analysis to detect volatile organic compounds and mixtures
    • Ricco A.J., Crooks R.M., Osbourne G.C. Surface acoustic wave chemical sensor arrays: new chemically sensitive interfaces combined with novel cluster analysis to detect volatile organic compounds and mixtures. Acc. Chem. Res. 31:1998;289-296.
    • (1998) Acc. Chem. Res. , vol.31 , pp. 289-296
    • Ricco, A.J.1    Crooks, R.M.2    Osbourne, G.C.3
  • 7
    • 0023363493 scopus 로고
    • Multicomponent analysis using an array of piezoelectric crystal sensors
    • Carey W.P., Beebe K., Kowalski B.R. Multicomponent analysis using an array of piezoelectric crystal sensors. Anal. Chem. 59:1987;1529-1534.
    • (1987) Anal. Chem. , vol.59 , pp. 1529-1534
    • Carey, W.P.1    Beebe, K.2    Kowalski, B.R.3
  • 8
    • 21844524304 scopus 로고
    • Environmental chemical sensing using quartz microbalance sensor arrays: Application of multicomponent analysis techniques
    • Hierlemann A., Weimar U., Kraus G., Gauglitz G. Environmental chemical sensing using quartz microbalance sensor arrays: application of multicomponent analysis techniques. Sens. Mater. 7:1995;179-189.
    • (1995) Sens. Mater. , vol.7 , pp. 179-189
    • Hierlemann, A.1    Weimar, U.2    Kraus, G.3    Gauglitz, G.4
  • 9
    • 0031233380 scopus 로고    scopus 로고
    • Generating sensor diversity through combinatorial polymer synthesis
    • Dickinson T.A., Walt D.R., White J., Kauer J.S. Generating sensor diversity through combinatorial polymer synthesis. Anal. Chem. 69:1997;3413-3418.
    • (1997) Anal. Chem. , vol.69 , pp. 3413-3418
    • Dickinson, T.A.1    Walt, D.R.2    White, J.3    Kauer, J.S.4
  • 10
    • 0023019419 scopus 로고
    • Detection of hazardous gases and vapors: Pattern recognition analysis of data from an electrochemical sensor array
    • Stetter J.R., Jurs P.C., Rose S.L. Detection of hazardous gases and vapors: pattern recognition analysis of data from an electrochemical sensor array. Anal. Chem. 58:1986;860-866.
    • (1986) Anal. Chem. , vol.58 , pp. 860-866
    • Stetter, J.R.1    Jurs, P.C.2    Rose, S.L.3
  • 11
    • 0032487350 scopus 로고    scopus 로고
    • Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent
    • Groves W.A., Zellers E.T., Frye G.C. Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: selection and characterization of the preconcentrator adsorbent. Anal. Chim. Acta. 371(2/3):1998;131-143.
    • (1998) Anal. Chim. Acta , vol.371 , Issue.2-3 , pp. 131-143
    • Groves, W.A.1    Zellers, E.T.2    Frye, G.C.3
  • 12
    • 0000462297 scopus 로고
    • Smart sensor system for trace organophosphorus and organosulfur vapor detection employing acoustic wave sensors, automated sample preconcentration, and pattern recognition
    • Grate J.W., Rose-Pehrsson S.L., Venezky D.L., Klusty M., Wohltjen H. Smart sensor system for trace organophosphorus and organosulfur vapor detection employing acoustic wave sensors, automated sample preconcentration, and pattern recognition. Anal. Chem. 65:1993;1868-1881.
    • (1993) Anal. Chem. , vol.65 , pp. 1868-1881
    • Grate, J.W.1    Rose-Pehrsson, S.L.2    Venezky, D.L.3    Klusty, M.4    Wohltjen, H.5
  • 14
    • 0024016835 scopus 로고
    • Computer modeling of polymer-coated ZnO/Si surface-acoustic-wave and lamb-wave chemical sensors
    • Zellers E.T., White R.M., Wenzel S.W. Computer modeling of polymer-coated ZnO/Si surface-acoustic-wave and lamb-wave chemical sensors. Sens. Actuators. 14:1988;35-45.
    • (1988) Sens. Actuators , vol.14 , pp. 35-45
    • Zellers, E.T.1    White, R.M.2    Wenzel, S.W.3
  • 15
    • 0025698999 scopus 로고
    • Flexural plate-wave gravimetric chemical sensor
    • Wenzel S.W., White R.M. Flexural plate-wave gravimetric chemical sensor. Sens. Actuators, A. 21/23:1990;700-703.
    • (1990) Sens. Actuators, a , vol.2123 , pp. 700-703
    • Wenzel, S.W.1    White, R.M.2
  • 16
    • 0024896853 scopus 로고
    • Flexural plate-wave sensor: chemical vapor sensing and electrostrictive excitation
    • Montreal, October 3-6
    • S.W. Wenzel, R.M. White, Flexural plate-wave sensor: chemical vapor sensing and electrostrictive excitation, Proc. IEEE Ultrasonics Symposium, Montreal, October 3-6, 1989.
    • (1989) Proc. IEEE Ultrasonics Symposium
    • Wenzel, S.W.1    White, R.M.2
  • 17
    • 0000352337 scopus 로고
    • Flexural plate wave devices for chemical analysis
    • Grate J.W., Wenzel S.W., White R.M. Flexural plate wave devices for chemical analysis. Anal. Chem. 63:1991;1552-1561.
    • (1991) Anal. Chem. , vol.63 , pp. 1552-1561
    • Grate, J.W.1    Wenzel, S.W.2    White, R.M.3
  • 20
    • 0026104208 scopus 로고
    • Solubility interactions and the design of chemically selective sorbent coatings for chemical sensors and arrays
    • Grate J.W., Abraham M. Solubility interactions and the design of chemically selective sorbent coatings for chemical sensors and arrays. Sens. Actuators, B. 3(2):1991;85-111.
    • (1991) Sens. Actuators, B , vol.3 , Issue.2 , pp. 85-111
    • Grate, J.W.1    Abraham, M.2
  • 21
    • 0003095531 scopus 로고    scopus 로고
    • Acoustic wave sensors
    • in: H. Baltes, W. Gopel, J. Hesse, (Eds.), Chap. 2, VCH, Weinheim, FRG
    • J.W. Grate, G.C. Frye, Acoustic wave sensors, in: H. Baltes, W. Gopel, J. Hesse, (Eds.), Sensors Update, Chap. 2, Vol. 2, VCH, Weinheim, FRG, 1996, pp. 37-83.
    • (1996) Sensors Update , vol.2 , pp. 37-83
    • Grate, J.W.1    Frye, G.C.2
  • 22
    • 0027645276 scopus 로고
    • Characterization of polymeric surface-acoustic-wave sensor coatings and semi-empirical models of sensor responses to organic vapors
    • Patrash S.J., Zellers E.T. Characterization of polymeric surface-acoustic-wave sensor coatings and semi-empirical models of sensor responses to organic vapors. Anal. Chem. 65:1993;2055-2066.
    • (1993) Anal. Chem. , vol.65 , pp. 2055-2066
    • Patrash, S.J.1    Zellers, E.T.2
  • 23
    • 0001226121 scopus 로고
    • Dewetting effects on polymer-coated surface-acoustic-wave vapor sensors
    • Grate J.W., McGill A.R. Dewetting effects on polymer-coated surface-acoustic-wave vapor sensors. Anal. Chem. 67:1995;4015-4019.
    • (1995) Anal. Chem. , vol.67 , pp. 4015-4019
    • Grate, J.W.1    McGill, A.R.2
  • 25
    • 0027575388 scopus 로고
    • Extended disjoint principal components regression analysis of SAW vapor sensor array responses
    • Zellers E.T., Pan T.S., Patrash S., Han M., Batterman S. Extended disjoint principal components regression analysis of SAW vapor sensor array responses. Sens. Actuators, B. 12(2):1993;123-133.
    • (1993) Sens. Actuators, B , vol.12 , Issue.2 , pp. 123-133
    • Zellers, E.T.1    Pan, T.S.2    Patrash, S.3    Han, M.4    Batterman, S.5
  • 26
    • 0033104270 scopus 로고    scopus 로고
    • Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays
    • Grate J.W., Patrash S.J., Kaganove S.N., Wise B.M. Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays. Anal. Chem. 71:1999;1033-1040.
    • (1999) Anal. Chem. , vol.71 , pp. 1033-1040
    • Grate, J.W.1    Patrash, S.J.2    Kaganove, S.N.3    Wise, B.M.4
  • 27
    • 0032185573 scopus 로고    scopus 로고
    • Establishing a limit of recognition for a vapor sensor array
    • Zellers E.T., Park J., Hsu T., Groves W.A. Establishing a limit of recognition for a vapor sensor array. Anal. Chem. 70:1998;4191-4201.
    • (1998) Anal. Chem. , vol.70 , pp. 4191-4201
    • Zellers, E.T.1    Park, J.2    Hsu, T.3    Groves, W.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.