메뉴 건너뛰기




Volumn 15, Issue 6, 2000, Pages 556-564

A comparison of fluorescent SSCP and denaturing HPLC for high throughput mutation scanning

Author keywords

ABCC7; CFTR; DHPLC; Fluorescent SSCP; Mutation detection; VHL; Von Hippel Lindau

Indexed keywords

DNA; DNA FRAGMENT;

EID: 0034078332     PISSN: 10597794     EISSN: None     Source Type: Journal    
DOI: 10.1002/1098-1004(200006)15:6<556::AID-HUMU7>3.0.CO;2-C     Document Type: Article
Times cited : (84)

References (21)
  • 1
    • 0024021305 scopus 로고
    • Reactivity of cytosine and thymine in single base-pair mismatches with hydroxylamine and osmium tetroxide and its application to the study of mutations
    • Cotton RGH, Rodrigues NR, Campbell RD. 1988. Reactivity of cytosine and thymine in single base-pair mismatches with hydroxylamine and osmium tetroxide and its application to the study of mutations. Proc Natl Acad Sci USA 85:4397-4401.
    • (1988) Proc Natl Acad Sci USA , vol.85 , pp. 4397-4401
    • Cotton, R.G.H.1    Rodrigues, N.R.2    Campbell, R.D.3
  • 2
    • 0031291660 scopus 로고    scopus 로고
    • Comparison of enzyme mismatch cleavage and chemical cleavage of mismatch on a defined set of heteroduplexes
    • Deeble VJ, Roberts E, Robinson MD, Woods CG, Bishop DT, Taylor GR. 1997. Comparison of enzyme mismatch cleavage and chemical cleavage of mismatch on a defined set of heteroduplexes. Genet Test 1:253-259.
    • (1997) Genet Test , vol.1 , pp. 253-259
    • Deeble, V.J.1    Roberts, E.2    Robinson, M.D.3    Woods, C.G.4    Bishop, D.T.5    Taylor, G.R.6
  • 4
    • 0023685544 scopus 로고
    • A survey on intron and exon lengths
    • Hawkins JD. 1988. A survey on intron and exon lengths. Nucleic Acids Research 16:9893-9908.
    • (1988) Nucleic Acids Research , vol.16 , pp. 9893-9908
    • Hawkins, J.D.1
  • 5
    • 0031263204 scopus 로고    scopus 로고
    • A streamlined mutation detection system: Multicolor post-PCR fluorescence labeling and single-strand conformational polymorphism analysis by capillary electrophoresis
    • Inazuka M, Wenz HM, Sakabe M, Tahira T, Hayashi K. 1997. A streamlined mutation detection system: multicolor post-PCR fluorescence labeling and single-strand conformational polymorphism analysis by capillary electrophoresis. Genome Research 7:1094-1103.
    • (1997) Genome Research , vol.7 , pp. 1094-1103
    • Inazuka, M.1    Wenz, H.M.2    Sakabe, M.3    Tahira, T.4    Hayashi, K.5
  • 6
    • 0032878113 scopus 로고    scopus 로고
    • Optimal temperature selection for mutation detection by denaturing HPLC and comparison to single-stranded conformation polymorphism and heteroduplex analysis
    • Jones AC, Austin J, Hansen N, Hoogendoorn B, Oefner PJ, Cheadle JP, O'Donovan MC. 1999. Optimal temperature selection for mutation detection by denaturing HPLC and comparison to single-stranded conformation polymorphism and heteroduplex analysis. Clinical Chemistry 45:1133-1140.
    • (1999) Clinical Chemistry , vol.45 , pp. 1133-1140
    • Jones, A.C.1    Austin, J.2    Hansen, N.3    Hoogendoorn, B.4    Oefner, P.J.5    Cheadle, J.P.6    O'Donovan, M.C.7
  • 7
    • 0031291719 scopus 로고    scopus 로고
    • Detection of single-nucleotide polymorphisms with the WAVE DNA fragment analysis system
    • Kuklin A, Munson K, Gjerde D, Haefele R, Taylor P. 1997. Detection of single-nucleotide polymorphisms with the WAVE DNA fragment analysis system. Genet Test 1:201-206.
    • (1997) Genet Test , vol.1 , pp. 201-206
    • Kuklin, A.1    Munson, K.2    Gjerde, D.3    Haefele, R.4    Taylor, P.5
  • 8
    • 0032982405 scopus 로고    scopus 로고
    • High-throughput single-stranded conformation polymorphism analysis by automated capillary electrophoresis: Robust multiplex analysis and pattern based identification of allelic variants
    • Larsen LA, Christiansen M, Vuust J, Andersen PS. 1999. High-throughput single-stranded conformation polymorphism analysis by automated capillary electrophoresis: robust multiplex analysis and pattern based identification of allelic variants. Hum Mutat 13:318-327.
    • (1999) Hum Mutat , vol.13 , pp. 318-327
    • Larsen, L.A.1    Christiansen, M.2    Vuust, J.3    Andersen, P.S.4
  • 10
    • 0032520681 scopus 로고    scopus 로고
    • Denaturing high performance liquid chromatography (DHPLC) used in the detection of germline and somatic mutations
    • Liu WG, Smith DI, Rechtzigel KJ, Thibodeau SN, James CD. 1998. Denaturing high performance liquid chromatography (DHPLC) used in the detection of germline and somatic mutations. Nucleic Acids Research 26:1396-1400.
    • (1998) Nucleic Acids Research , vol.26 , pp. 1396-1400
    • Liu, W.G.1    Smith, D.I.2    Rechtzigel, K.J.3    Thibodeau, S.N.4    James, C.D.5
  • 11
    • 0031292158 scopus 로고    scopus 로고
    • Denaturing HPLC-identified novel FBN1 mutations, polymorphisms, and sequence variants in Marfan syndrome and related connective tissue disorders
    • Liu WO, Oefner PJ, Qian CP, Odom RS, Francke U. 1997. Denaturing HPLC-identified novel FBN1 mutations, polymorphisms, and sequence variants in Marfan syndrome and related connective tissue disorders. Genetic Testing 1:237-242.
    • (1997) Genetic Testing , vol.1 , pp. 237-242
    • Liu, W.O.1    Oefner, P.J.2    Qian, C.P.3    Odom, R.S.4    Francke, U.5
  • 12
    • 0022422655 scopus 로고
    • Nearly all single base substitutions in DNA fragments joined to a GC-clamp can be detected by denaturing gradient gel-electrophoresis
    • Myers RM, Fischer SG, Lerman LS, Maniatis, T. 1985. Nearly all single base substitutions in DNA fragments joined to a GC-clamp can be detected by denaturing gradient gel-electrophoresis. Nucleic Acids Research 13:3131-3145.
    • (1985) Nucleic Acids Research , vol.13 , pp. 3131-3145
    • Myers, R.M.1    Fischer, S.G.2    Lerman, L.S.3    Maniatis, T.4
  • 13
    • 0023476285 scopus 로고
    • Detection and localization of single base changes by denaturing gradient gel-electrophoresis
    • Myers RM, Maniatis T, Lerman LS. 1987. Detection and localization of single base changes by denaturing gradient gel-electrophoresis. Methods in Enzymology 155:501-527.
    • (1987) Methods in Enzymology , vol.155 , pp. 501-527
    • Myers, R.M.1    Maniatis, T.2    Lerman, L.S.3
  • 14
    • 0029684436 scopus 로고    scopus 로고
    • Single-strand conformation polymorphism (SSCP) can be explained by semistable conformation dynamics of single-stranded DNA
    • Nakabayashi Y, Nishigaki K. 1996. Single-strand conformation polymorphism (SSCP) can be explained by semistable conformation dynamics of single-stranded DNA. J Biochem (Tokyo) 120:320-325.
    • (1996) J Biochem (Tokyo) , vol.120 , pp. 320-325
    • Nakabayashi, Y.1    Nishigaki, K.2
  • 17
    • 0024595101 scopus 로고
    • Detection of polymorphisms of human DNA by gel electrophoresis as single-strand conformation polymorphisms
    • Orita M, Iwahana H, Kanazawa H, Hayashi K, Sekiya T. 1989. Detection of polymorphisms of human DNA by gel electrophoresis as single-strand conformation polymorphisms. Proc Natl Acad Sci USA 86:2766-2770.
    • (1989) Proc Natl Acad Sci USA , vol.86 , pp. 2766-2770
    • Orita, M.1    Iwahana, H.2    Kanazawa, H.3    Hayashi, K.4    Sekiya, T.5
  • 19
    • 0027193630 scopus 로고
    • The sensitivity of single-strand conformation polymorphism analysis for the detection of single base substitutions
    • Sheffield VC, Beck JS, Kwitek AE, Sandstrom DW, Stone EM. 1993. The sensitivity of single-strand conformation polymorphism analysis for the detection of single base substitutions. Genomics 16:325-332.
    • (1993) Genomics , vol.16 , pp. 325-332
    • Sheffield, V.C.1    Beck, J.S.2    Kwitek, A.E.3    Sandstrom, D.W.4    Stone, E.M.5
  • 21
    • 0028899568 scopus 로고
    • Screening for mutations by enzyme mismatch cleavage with T4 endonuclease-7
    • Youil R, Kemper BW, Cotton RGH. 1995. Screening for mutations by enzyme mismatch cleavage with T4 endonuclease-7. Proc Natl Acad Sci USA 92:87-91.
    • (1995) Proc Natl Acad Sci USA , vol.92 , pp. 87-91
    • Youil, R.1    Kemper, B.W.2    Cotton, R.G.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.