Volumn 77, Issue 3, 1999, Pages 293-297

Ultrasound biomicroscopy. III. Accuracy and agreement of measurements

Author keywords

Accurracy; Anterior chamber depth; Anterior eye segment ultrasonography; Central cornea thickness; Microscopy; Ultrasonography instrumentation

Indexed keywords

ANTERIOR EYE CHAMBER; ARTICLE; BIOMICROSCOPY; CORNEA THICKNESS; DIAGNOSTIC ACCURACY; EYE AXIS LENGTH; INTERMETHOD COMPARISON; OPTICS; PACHOMETRY; PRIORITY JOURNAL; ULTRASOUND; VISUAL SYSTEM PARAMETERS;

EID: 0032972071     PISSN: 13953907     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1600-0420.1999.770309.x     Document Type: Article
Times cited : (40)

References (15)
  • 1
    • 0021280744 scopus 로고
    • Echographische Messung der Bulbuslänge in pseudophaken Augen
    • Ataria LG, Freudiger H (1984): Echographische Messung der Bulbuslänge in pseudophaken Augen. Klin Mbl Augenheilk 184: 406-409.
    • (1984) Klin Mbl Augenheilk , vol.184 , pp. 406-409
    • Ataria, L.G.1    Freudiger, H.2
  • 2
    • 84908219488 scopus 로고
    • Statistical Methods for Assessing Agreement between Two Methods of Clinical Measurement
    • Bland JM, Altman DG (1986): Statistical Methods for Assessing Agreement between Two Methods of Clinical Measurement. Lancet: 307-310.
    • (1986) Lancet , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 3
    • 0017350810 scopus 로고
    • A technical improvement of the Haag-Streit pachometer
    • Copenh
    • Ehlers N, Sperling S (1977): A technical improvement of the Haag-Streit pachometer. Acta Ophthalmol (Copenh) 55: 333-336.
    • (1977) Acta Ophthalmol , vol.55 , pp. 333-336
    • Ehlers, N.1    Sperling, S.2
  • 4
    • 0012416206 scopus 로고
    • Determination of the velocity of ultrasound in ocular tissues at different temperatures
    • Copenh
    • Jansson F, Sundmark E (1961): Determination of the velocity of ultrasound in ocular tissues at different temperatures. Acta Ophthalmol (Copenh) 39: 899-910.
    • (1961) Acta Ophthalmol , vol.39 , pp. 899-910
    • Jansson, F.1    Sundmark, E.2
  • 6
    • 0019204989 scopus 로고
    • On optical measurement of corneal thickness. II. The measuring conditions and sources of error
    • Copenh
    • Olsen T, Nielsen CB, Ehlers N (1980): On optical measurement of corneal thickness. II. The measuring conditions and sources of error. Acta Ophthalmol (Copenh) 58: 975-984.
    • (1980) Acta Ophthalmol , vol.58 , pp. 975-984
    • Olsen, T.1    Nielsen, C.B.2    Ehlers, N.3
  • 7
    • 0025166441 scopus 로고
    • Subsurface Ultrasound Imaging of the Intact Eye
    • Pavlin CJ, Sherar MD, Foster FS (1990): Subsurface Ultrasound Imaging of the Intact Eye. Ophthalmol 97: 244-250.
    • (1990) Ophthalmol , vol.97 , pp. 244-250
    • Pavlin, C.J.1    Sherar, M.D.2    Foster, F.S.3
  • 8
    • 0026552857 scopus 로고
    • Ultrasound Biomicroscopy of Anterior Segment Structures in Normal and Glaucomatous Eyes
    • Pavlin CJ, Harasiewicz K, Foster FS (1992): Ultrasound Biomicroscopy of Anterior Segment Structures in Normal and Glaucomatous Eyes. Am J Ophthalmol 113: 381-389.
    • (1992) Am J Ophthalmol , vol.113 , pp. 381-389
    • Pavlin, C.J.1    Harasiewicz, K.2    Foster, F.S.3
  • 10
    • 0021035876 scopus 로고
    • Evaluation and Comparison of Sources of Variability in the Measurement of Corneal Thickness with Ultrasonic and Optical Pachometers
    • Salz JJ, Azen SP, Berstein J, Caroline P, Villasenor RA, Schanzlin DJ (1983): Evaluation and Comparison of Sources of Variability in the Measurement of Corneal Thickness with Ultrasonic and Optical Pachometers. Ophthalmic Surg 14: 750-754.
    • (1983) Ophthalmic Surg , vol.14 , pp. 750-754
    • Salz, J.J.1    Azen, S.P.2    Berstein, J.3    Caroline, P.4    Villasenor, R.A.5    Schanzlin, D.J.6
  • 12
    • 2442732685 scopus 로고
    • Über die Ausbreitungsgeschwindigkeit des Ultraschalls in den augengeweben
    • Tshewnenko AA (1965): Über die Ausbreitungsgeschwindigkeit des Ultraschalls in den augengeweben. Z Humbolt Univ Berlin Math Naturwiss Reihe 14: 67-69.
    • (1965) Z Humbolt Univ Berlin Math Naturwiss Reihe , vol.14 , pp. 67-69
    • Tshewnenko, A.A.1
  • 14
    • 0031820198 scopus 로고    scopus 로고
    • Ultrasound Biomicroscopy. 1. Precision of Measurements
    • Urbak SF (1998): Ultrasound Biomicroscopy. 1. Precision of Measurements. Acta Ophthalmol Scand 76: 447-455.
    • (1998) Acta Ophthalmol Scand , vol.76 , pp. 447-455
    • Urbak, S.F.1
  • 15
    • 0029219215 scopus 로고
    • Ultrasound Characterization of Ocular Tissue in the Frequency Range 50 MHz to 100 MHz
    • Ye SG, Harasiewics KA, Pavlin CJ, Foster FS (1995): Ultrasound Characterization of Ocular Tissue in the Frequency Range 50 MHz to 100 MHz. IEEE Trans UFFC 42: 8-14.
    • (1995) IEEE Trans UFFC , vol.42 , pp. 8-14
    • Ye, S.G.1    Harasiewics, K.A.2    Pavlin, C.J.3    Foster, F.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.