메뉴 건너뛰기




Volumn 122, Issue 1, 1996, Pages 53-57

Increase in iris-lens contact after laser iridotomy for pupillary block angle closure

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMY; ANTERIOR EYE CHAMBER; ANTERIOR EYE CHAMBER ANGLE; ARTICLE; CLINICAL ARTICLE; HUMAN; IRIDOTOMY; IRIS; LASER SURGERY; LENS; PRIORITY JOURNAL; REFRACTION ERROR;

EID: 0029900125     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9394(14)71963-4     Document Type: Article
Times cited : (90)

References (11)
  • 1
    • 0024237291 scopus 로고
    • A method for improved biometry of the anterior chamber with a Scheimpflug technique
    • Richards DW Russell SR Anderson DR A method for improved biometry of the anterior chamber with a Scheimpflug technique Invest Ophthalmol Vis Sci 29 1988 1826 1835
    • (1988) Invest Ophthalmol Vis Sci , vol.29 , pp. 1826-1835
    • Richards, DW1    Russell, SR2    Anderson, DR3
  • 2
    • 0025100074 scopus 로고
    • The effect of iridotomy on iris contour
    • Jin JC Anderson DR The effect of iridotomy on iris contour Am J Ophthalmol 110 1990 260 263
    • (1990) Am J Ophthalmol , vol.110 , pp. 260-263
    • Jin, JC1    Anderson, DR2
  • 3
    • 0026032399 scopus 로고
    • The physiologic characteristics of relative pupillary block
    • Anderson DR Jin JC Wright MM The physiologic characteristics of relative pupillary block Am J Ophthalmol 111 1991 344 350
    • (1991) Am J Ophthalmol , vol.111 , pp. 344-350
    • Anderson, DR1    Jin, JC2    Wright, MM3
  • 4
    • 0021348982 scopus 로고
    • Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma
    • Lee DA Brubaker RF Illstrup DM Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma Arch Ophthalmol 102 1984 46 50
    • (1984) Arch Ophthalmol , vol.102 , pp. 46-50
    • Lee, DA1    Brubaker, RF2    Illstrup, DM3
  • 5
    • 0025972463 scopus 로고
    • A physical analysis of the factors that determine the contour of the iris
    • Tiedeman JS A physical analysis of the factors that determine the contour of the iris Am J Ophthalmol 111 1991 338 343
    • (1991) Am J Ophthalmol , vol.111 , pp. 338-343
    • Tiedeman, JS1
  • 6
    • 0025166441 scopus 로고
    • Subsurface ultrasound microscopic imaging of the intact eye
    • Pavlin CJ Sherar MD Foster FS Subsurface ultrasound microscopic imaging of the intact eye Ophthalmology 97 1990 244 250
    • (1990) Ophthalmology , vol.97 , pp. 244-250
    • Pavlin, CJ1    Sherar, MD2    Foster, FS3
  • 8
    • 0026552857 scopus 로고
    • Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes
    • Pavlin CJ Harasiewicz K Eng P Foster FS Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes Am J Ophthalmol 113 1992 381 389
    • (1992) Am J Ophthalmol , vol.113 , pp. 381-389
    • Pavlin, CJ1    Harasiewicz, K2    Eng, P3    Foster, FS4
  • 9
    • 0018893759 scopus 로고
    • Central anterior chamber depth after laser iridectomy
    • Jacobs IH Krohn DL Central anterior chamber depth after laser iridectomy Am J Ophthalmol 88 1980 865 867
    • (1980) Am J Ophthalmol , vol.88 , pp. 865-867
    • Jacobs, IH1    Krohn, DL2
  • 10
    • 0028331269 scopus 로고
    • Ultrasound biomicroscopy in pigment dispersion syndrome
    • Potash SD Tello C Liebmann J Ritch R Ultrasound biomicroscopy in pigment dispersion syndrome Ophthalmology 101 1994 332 339
    • (1994) Ophthalmology , vol.101 , pp. 332-339
    • Potash, SD1    Tello, C2    Liebmann, J3    Ritch, R4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.