메뉴 건너뛰기




Volumn 49, Issue 4, 2000, Pages 369-375

Physiologically guided angioplasty in support to a provisional stenting strategy: Immediate and six-month outcome

Author keywords

Angioplasty; Coronary velocity reserve; Intracoronary Doppler; Restenosis; Stent

Indexed keywords

ADULT; ANGIOCARDIOGRAPHY; ARTICLE; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY DILATATION; CORONARY ARTERY DISEASE; CORONARY ARTERY OBSTRUCTION; FEMALE; HEART INFARCTION; HEART MUSCLE REVASCULARIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; STENT; UNSTABLE ANGINA PECTORIS;

EID: 0034038263     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-726X(200004)49:4<369::AID-CCD4>3.0.CO;2-J     Document Type: Article
Times cited : (12)

References (25)
  • 3
    • 0027486827 scopus 로고
    • Restenosis revisited: Insights provided by quantitative coronary angiography
    • Serruys PW, Foley DP, Kirkeeide RL, King SB. Restenosis revisited: insights provided by quantitative coronary angiography. Am Heart J 1993;126:1243-1267.
    • (1993) Am Heart J , vol.126 , pp. 1243-1267
    • Serruys, P.W.1    Foley, D.P.2    Kirkeeide, R.L.3    King, S.B.4
  • 4
    • 0023680371 scopus 로고
    • Normalization of coronary flow reserve by percutaneous transluminal coronary angioplasty
    • Zijlstra F, Reiber JC, Juilliere Y, Serruys PW. Normalization of coronary flow reserve by percutaneous transluminal coronary angioplasty. Am J Cardiol 1988;61:55-60.
    • (1988) Am J Cardiol , vol.61 , pp. 55-60
    • Zijlstra, F.1    Reiber, J.C.2    Juilliere, Y.3    Serruys, P.W.4
  • 7
    • 0027302810 scopus 로고
    • Assessing the hemodynamic significance of coronary artery stenoses: Analysis of translesional pressure-flow velocity relations in patients
    • Donohue TJ, Kern MJ, Aguirre FV, Bach RG, Wolford T, Bell CA, Segal J. Assessing the hemodynamic significance of coronary artery stenoses: analysis of translesional pressure-flow velocity relations in patients. J Am Coll Cardiol 1993;22:449-458.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 449-458
    • Donohue, T.J.1    Kern, M.J.2    Aguirre, F.V.3    Bach, R.G.4    Wolford, T.5    Bell, C.A.6    Segal, J.7
  • 8
    • 0004786851 scopus 로고    scopus 로고
    • Pronostic value of coronary flow velocity and diameter stenosis in assessing the short and long term outcome of balloon angioplasty: The DEBATE study (Doppler Endpoints Balloon Angioplasty Trial Europe)
    • Serruys PW, Di Mario C. Pronostic value of coronary flow velocity and diameter stenosis in assessing the short and long term outcome of balloon angioplasty: the DEBATE study (Doppler Endpoints Balloon Angioplasty Trial Europe). Circulation 1996; 94:1847.
    • (1996) Circulation , vol.94 , pp. 1847
    • Serruys, P.W.1    Di Mario, C.2
  • 13
    • 0028836952 scopus 로고
    • Effect of high dose angiotensin converting enzyme inhibition on restenosis: Final results of the MARCATOR study, a multicenter, double blind, placebo controlled trial of cilazapril: The Multicenter American Research Trial with Cilazapril After Angioplasty to prevent Transluminal Coronary Obstruction and Restenosis (MARCATOr) study group
    • Faxon DP. Effect of high dose angiotensin converting enzyme inhibition on restenosis: final results of the MARCATOR Study, a multicenter, double blind, placebo controlled trial of cilazapril: the Multicenter American Research Trial With Cilazapril After Angioplasty to Prevent Transluminal Coronary Obstruction and Restenosis (MARCATOR) Study Group. J Am Coll Cardiol 1995; 25;362-369.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 362-369
    • Faxon, D.P.1
  • 14
    • 0027319235 scopus 로고    scopus 로고
    • A comparison of directional atherectomy in patients with coronary angioplasty in patients with coornary artery disease
    • Topol EJ, Leya F, Pinkerton, et al. A comparison of directional atherectomy in patients with coronary angioplasty in patients with coornary artery disease. N Engl J Med 1993:221-227.
    • N Engl J Med , vol.1993 , pp. 221-227
    • Topol, E.J.1    Leya, F.2
  • 15
    • 0343824319 scopus 로고    scopus 로고
    • Real life stenting: A comparison of target vessel revascularisation in Benestent-Stress lesions
    • Tilli FV, Aliabadi D, Kinn JW, Kaplan BM, Benzuly KH, Safian RD. Real life stenting: a comparison of target vessel revascularisation in Benestent-Stress lesions. Circulation 1996;94:1934.
    • (1996) Circulation , vol.94 , pp. 1934
    • Tilli, F.V.1    Aliabadi, D.2    Kinn, J.W.3    Kaplan, B.M.4    Benzuly, K.H.5    Safian, R.D.6
  • 16
    • 85008721751 scopus 로고    scopus 로고
    • Six month clinical and angiographic outcomes after coronary stenting in current clinical practice
    • Antoniucci D, Valenti R, Trapini M. Six month clinical and angiographic outcomes after coronary stenting in current clinical practice. Circulation 1997;96(Suppl I):1-709.
    • (1997) Circulation , vol.96 , Issue.SUPPL. I , pp. 1-709
    • Antoniucci, D.1    Valenti, R.2    Trapini, M.3
  • 20
    • 0024443037 scopus 로고
    • A comparison of two methods to measure coronary flow reserve in the setting of coronary angioplasty: Intracoronary blood flow velocity measurements with a Doppler catheter, and digital subtraction cineangiography
    • Serruys PW, Zijlstra F, Laarman GJ, Reiber HH, Beatt K, Roelandt J. A comparison of two methods to measure coronary flow reserve in the setting of coronary angioplasty: intracoronary blood flow velocity measurements with a Doppler catheter, and digital subtraction cineangiography. Eur Heart J 1989;10:725-736.
    • (1989) Eur Heart J , vol.10 , pp. 725-736
    • Serruys, P.W.1    Zijlstra, F.2    Laarman, G.J.3    Reiber, H.H.4    Beatt, K.5    Roelandt, J.6
  • 21
    • 0027196743 scopus 로고
    • Intracoronary pressure and flow velocity with sensor-tip guidewires: A new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions
    • Serruys PW, Di Mario C, Meneveau N, de Jaegere P, Strikwerda S, de Feyter PJ, Emanuelsson H. Intracoronary pressure and flow velocity with sensor-tip guidewires: a new methodologic approach for assessment of coronary hemodynamics before and after coronary interventions. Am J Cardiol 1993;71:41D-53D.
    • (1993) Am J Cardiol , vol.71
    • Serruys, P.W.1    Di Mario, C.2    Meneveau, N.3    De Jaegere, P.4    Strikwerda, S.5    De Feyter, P.J.6    Emanuelsson, H.7
  • 22
    • 0030297750 scopus 로고    scopus 로고
    • Variations in normal coronary vasodilatory reserve stratified by artery, gender, heart transplantation and coronary artery disease
    • Kern MJ, Bach RG, Mechem CJ, Caracciolo EA, Aguirre FV, Miller LW, Donohue TJ. Variations in normal coronary vasodilatory reserve stratified by artery, gender, heart transplantation and coronary artery disease. J Am Coll Cardiol 1996;28: 1154-1160.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 1154-1160
    • Kern, M.J.1    Bach, R.G.2    Mechem, C.J.3    Caracciolo, E.A.4    Aguirre, F.V.5    Miller, L.W.6    Donohue, T.J.7
  • 23
    • 0029841529 scopus 로고    scopus 로고
    • Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperhemic flow versus pressure slope index, and fractional flow reserve
    • de Bruyne B, Bartunek J, Sys S, Pijls NHJ, Heyndrickx, GR, Wijns W. Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperhemic flow versus pressure slope index, and fractional flow reserve. Circulation 1996;94:1842-1849.
    • (1996) Circulation , vol.94 , pp. 1842-1849
    • De Bruyne, B.1    Bartunek, J.2    Sys, S.3    Pijls, N.H.J.4    Heyndrickx, G.R.5    Wijns, W.6
  • 24
    • 0023616244 scopus 로고
    • Coronary vasodilator reserve persists despite tachycardia and myocardial ischemia
    • Bristow JD, McFalls EO, Anselone CG, Pantely GA. Coronary vasodilator reserve persists despite tachycardia and myocardial ischemia. Am J Physiol 1987;253:H422-H431.
    • (1987) Am J Physiol , vol.253
    • Bristow, J.D.1    McFalls, E.O.2    Anselone, C.G.3    Pantely, G.A.4
  • 25
    • 0025277969 scopus 로고
    • Interstudy variability of coronary flow reserve: Influence of heart rate, arterial pressure, and ventricular preload
    • McGinn AL, White CW, Wilson RF. Interstudy variability of coronary flow reserve: influence of heart rate, arterial pressure, and ventricular preload. Circulation 1990;81:1319-1330.
    • (1990) Circulation , vol.81 , pp. 1319-1330
    • McGinn, A.L.1    White, C.W.2    Wilson, R.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.