메뉴 건너뛰기




Volumn 29, Issue 7, 1997, Pages 1520-1527

Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: A combined intravascular ultrasound doppler flow and imaging study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANGIOGRAPHY; ANGIOPLASTY; ARTICLE; AUTOREGULATION; CLINICAL ARTICLE; CORONARY ARTERY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY DISEASE; DOPPLER FLOWMETER; FEMALE; HUMAN; IMAGE ANALYSIS; MALE; PRIORITY JOURNAL; RESTENOSIS; STENT; TRANSLUMINAL CORONARY ANGIOPLASTY;

EID: 0030970596     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0735-1097(97)00082-X     Document Type: Article
Times cited : (100)

References (40)
  • 1
    • 0028123099 scopus 로고
    • A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease
    • Serruys PW, de Jaegere P, Kiemenej F, et al. A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N Engl J Med. 331:1994;489-495.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    De Jaegere, P.2    Kiemenej, F.3
  • 2
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • Fischman DL, Leon MB, Baim D, et al. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N Engl J Med. 331:1994;496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.3
  • 3
    • 0024393107 scopus 로고
    • Restenosis after coronary angioplasty: Potential biologic determinants and role of intimal hyperplasia
    • Liu MW, Roubin GS, King SB. Restenosis after coronary angioplasty potential biologic determinants and role of intimal hyperplasia . Circulation. 79:1989;1374-1387.
    • (1989) Circulation , vol.79 , pp. 1374-1387
    • Liu, M.W.1    Roubin, G.S.2    King, S.B.3
  • 4
    • 0023111956 scopus 로고
    • Shear stress regulation of artery lumen diameter in experimental atherogenesis
    • Zarins CK, Zatina MA, Giddens DP, Ku DN, Glagov S. Shear stress regulation of artery lumen diameter in experimental atherogenesis. J Vasc Surg. 5:1987;413-420.
    • (1987) J Vasc Surg , vol.5 , pp. 413-420
    • Zarins, C.K.1    Zatina, M.A.2    Giddens, D.P.3    Ku, D.N.4    Glagov, S.5
  • 5
    • 0023875978 scopus 로고
    • The effect of coronary angioplasty on coronary flow reserve
    • Wilson RF, Johnson MR, Marcus ML, et al. The effect of coronary angioplasty on coronary flow reserve. Circulation. 77:1988;873-885.
    • (1988) Circulation , vol.77 , pp. 873-885
    • Wilson, R.F.1    Johnson, M.R.2    Marcus, M.L.3
  • 6
    • 0024560324 scopus 로고
    • Impaired coronary vasodilatory reserve in the immediate postcoronary angioplasty period: Analysis of coronary arterial velocity flow indexes and regional cardiac venous efflux
    • Kern MJ, Deligonul U, Vandormael M, et al. Impaired coronary vasodilatory reserve in the immediate postcoronary angioplasty period analysis of coronary arterial velocity flow indexes and regional cardiac venous efflux . J Am Coll Cardiol. 13:1989;860-872.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 860-872
    • Kern, M.J.1    Deligonul, U.2    Vandormael, M.3
  • 8
    • 0020080324 scopus 로고
    • Release of atherosclerotic debris after transluminal angioplasty
    • Block PC, Elmer D, Fallon JT. Release of atherosclerotic debris after transluminal angioplasty. Circulation. 65:1982;950-952.
    • (1982) Circulation , vol.65 , pp. 950-952
    • Block, P.C.1    Elmer, D.2    Fallon, J.T.3
  • 9
    • 0024536835 scopus 로고
    • "crackers, breakers, stretchers, drillers, scrapers, shavers, burners, welders and melters" - The future treatment of atherosclerotic coronary artery disease?: A clinical-morphologic assessment
    • Waller BF. "Crackers, breakers, stretchers, drillers, scrapers, shavers, burners, welders and melters" - the future treatment of atherosclerotic coronary artery disease? A clinical-morphologic assessment . J Am Coll Cardiol. 13:1989;969-987.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 969-987
    • Waller, B.F.1
  • 10
    • 0021321801 scopus 로고
    • Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis?
    • White CW, Wright CB, Doty DB, et al. Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? N Engl J Med. 310:1984;819-824.
    • (1984) N Engl J Med , vol.310 , pp. 819-824
    • White, C.W.1    Wright, C.B.2    Doty, D.B.3
  • 11
    • 0025935201 scopus 로고
    • Quantitative coronary angiography to measure progression and regression of coronary atherosclerosis: Value, limitations, and implications for clinical trials
    • de Feyter PJ, Serruys PW, Davies MJ, Richardson P, Lubsen J, Oliver MF. Quantitative coronary angiography to measure progression and regression of coronary atherosclerosis value, limitations, and implications for clinical trials . Circulation. 84:1991;412-423.
    • (1991) Circulation , vol.84 , pp. 412-423
    • De Feyter, P.J.1    Serruys, P.W.2    Davies, M.J.3    Richardson, P.4    Lubsen, J.5    Oliver, M.F.6
  • 12
    • 0028876102 scopus 로고
    • Our preoccupation with coronary luminology: The dissociation between clinical and angiographic findings in ischemic heart disease
    • Topol EJ, Nissen SE. Our preoccupation with coronary luminology the dissociation between clinical and angiographic findings in ischemic heart disease . Circulation. 92:1995;2333-2342.
    • (1995) Circulation , vol.92 , pp. 2333-2342
    • Topol, E.J.1    Nissen, S.E.2
  • 13
    • 0024453084 scopus 로고
    • Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro
    • Tobis JM, Mallery JA, Gessert J, et al. Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro. Circulation. 80:1989;873-882.
    • (1989) Circulation , vol.80 , pp. 873-882
    • Tobis, J.M.1    Mallery, J.A.2    Gessert, J.3
  • 14
  • 15
    • 0027518452 scopus 로고
    • Intracoronary ultrasound imaging: Correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty
    • Hodgson JM, Reddy KG, Suneja R, Nair RN, Lesnefsky EJ, Sheehan HM. Intracoronary ultrasound imaging correlation of plaque morphology with angiography, clinical syndrome and procedural results in patients undergoing coronary angioplasty . J Am Coll Cardiol. 21:1993;35-44.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 35-44
    • Hodgson, J.M.1    Reddy, K.G.2    Suneja, R.3    Nair, R.N.4    Lesnefsky, E.J.5    Sheehan, H.M.6
  • 17
    • 0027477325 scopus 로고
    • Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endoluminal enlargement by angioplasty
    • Ofili EO, Kern MJ, Labovitz AJ, et al. Analysis of coronary blood flow velocity dynamics in angiographically normal and stenosed arteries before and after endoluminal enlargement by angioplasty. J Am Coll Cardiol. 21:1993;308-316.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 308-316
    • Ofili, E.O.1    Kern, M.J.2    Labovitz, A.J.3
  • 18
    • 0026637436 scopus 로고
    • Alterations of phasic coronary artery flow velocity in man during percutaneous coronary angioplasty
    • Segal J, Kern MJ, Scott NA, et al. Alterations of phasic coronary artery flow velocity in man during percutaneous coronary angioplasty. J Am Coll Cardiol. 20:1992;276-286.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 276-286
    • Segal, J.1    Kern, M.J.2    Scott, N.A.3
  • 19
    • 0027302810 scopus 로고
    • Assessing the hemodynamic significance of coronary artery stenoses: Analysis of translesional pressure-flow velocity relationships in patients
    • Donohue TJ, Kern MJ, Aguirre FV, et al. Assessing the hemodynamic significance of coronary artery stenoses analysis of translesional pressure-flow velocity relationships in patients . J Am Coll Cardiol. 22:1993;449-458.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 449-458
    • Donohue, T.J.1    Kern, M.J.2    Aguirre, F.V.3
  • 20
    • 0026504959 scopus 로고
    • Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity
    • Doucette JW, Corl PD, Payne HM, et al. Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity. Circulation. 85:1992;1899-1911.
    • (1992) Circulation , vol.85 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.M.3
  • 22
    • 0028025621 scopus 로고
    • Measurement of volumetric coronary blood flow by simultaneous intravascular two-dimensional and Doppler ultrasound: Validation in an animal model
    • Chou TM, Sudhir K, Iwanaga S, Chatterjee K, Yock PG. Measurement of volumetric coronary blood flow by simultaneous intravascular two-dimensional and Doppler ultrasound validation in an animal model . Am Heart J. 128:1994;237-243.
    • (1994) Am Heart J , vol.128 , pp. 237-243
    • Chou, T.M.1    Sudhir, K.2    Iwanaga, S.3    Chatterjee, K.4    Yock, P.G.5
  • 23
    • 0025352353 scopus 로고
    • Intravascular ultrasound imaging: In vitro validation and pathologic correlation
    • Nishimura RA, Edwards WD, Warnes CA, et al. Intravascular ultrasound imaging in vitro validation and pathologic correlation . J Am Coll Cardiol. 16:1990;145-154.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 145-154
    • Nishimura, R.A.1    Edwards, W.D.2    Warnes, C.A.3
  • 24
    • 0026631097 scopus 로고
    • Intravascular ultrasound imaging of coronary arteries: Is three layers the norm?
    • Fitzgerald PJ, Goar FG, Connolly RJ, et al. Intravascular ultrasound imaging of coronary arteries is three layers the norm? Circulation. 86:1992;154-158.
    • (1992) Circulation , vol.86 , pp. 154-158
    • Fitzgerald, P.J.1    Goar, F.G.2    Connolly, R.J.3
  • 25
    • 0025250288 scopus 로고
    • Coronary artery imaging with intravascular high-frequency ultrasound
    • Potkin BN, Bartorelli AL, Gessert JM, et al. Coronary artery imaging with intravascular high-frequency ultrasound. Circulation. 81:1990;575-585.
    • (1990) Circulation , vol.81 , pp. 575-585
    • Potkin, B.N.1    Bartorelli, A.L.2    Gessert, J.M.3
  • 26
    • 0000638007 scopus 로고
    • Does adjunct coronary stenting in comparison to balloon angioplasty have an impact on Doppler flow velocity parameters? [abstract]
    • Haude M, Baumgart D, Caspari G, Erbel R. Does adjunct coronary stenting in comparison to balloon angioplasty have an impact on Doppler flow velocity parameters? [abstract]. Circulation. 92:(Suppl I):1995;I-547.
    • (1995) Circulation , vol.92 , Issue.SUPPL. I , pp. 547
    • Haude, M.1    Baumgart, D.2    Caspari, G.3    Erbel, R.4
  • 27
    • 0000638009 scopus 로고
    • Does coronary stenting following balloon angioplasty improve distal coronary flow reserve? [abstract]
    • Verna E, Gil R, DiMario C, Sunamura M, Gurne O, Porenta G. Does coronary stenting following balloon angioplasty improve distal coronary flow reserve? [abstract]. Circulation. 92:(Suppl I):1995;I-536.
    • (1995) Circulation , vol.92 , Issue.SUPPL. I , pp. 536
    • Verna, E.1    Gil, R.2    Dimario, C.3    Sunamura, M.4    Gurne, O.5    Porenta, G.6
  • 28
    • 0025098045 scopus 로고
    • Coronary flow reserve as a physiologic measure of stenosis severity
    • Gould KL, Kirkeeide RL, Buchi M. Coronary flow reserve as a physiologic measure of stenosis severity. J Am Coll Cardiol. 15:1990;459-474.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 459-474
    • Gould, K.L.1    Kirkeeide, R.L.2    Buchi, M.3
  • 29
    • 0030297750 scopus 로고    scopus 로고
    • Variations in normal coronary vasodilatory reserve stratified by artery, gender, heart transplantation and coronary artery disease
    • Kern MJ, Bach RG, Mechem C, et al. Variations in normal coronary vasodilatory reserve stratified by artery, gender, heart transplantation and coronary artery disease. J Am Coll Cardiol. 28:1996;1154-1160.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 1154-1160
    • Kern, M.J.1    Bach, R.G.2    Mechem, C.3
  • 30
    • 0004786851 scopus 로고    scopus 로고
    • Prognostic value of coronary flow velocity and diameter stenosis in assessing the short and long term outcome of balloon angioplasty: The DEBATE study (Doppler Endpoints Balloon Angioplasty Trial in Europe) [abstract]
    • Serruys PW, Di Mario C. Prognostic value of coronary flow velocity and diameter stenosis in assessing the short and long term outcome of balloon angioplasty the DEBATE study (Doppler Endpoints Balloon Angioplasty Trial in Europe) [abstract] . Circulation. 94:(Suppl I):1996;I-317.
    • (1996) Circulation , vol.94 , Issue.SUPPL. I , pp. 317
    • Serruys, P.W.1    Di Mario, C.2
  • 32
    • 0025813151 scopus 로고
    • Application of IVUS for detection and quantitation of coronary atherosclerosis
    • Nissen SE, Gurley JC. Application of IVUS for detection and quantitation of coronary atherosclerosis. Int J Card Imaging. 6:1991;165-177.
    • (1991) Int J Card Imaging , vol.6 , pp. 165-177
    • Nissen, S.E.1    Gurley, J.C.2
  • 33
    • 0025305130 scopus 로고
    • The significance of coronary reserve in clinical heart disease
    • Strauer B. The significance of coronary reserve in clinical heart disease. J Am Coll Cardiol. 15:1990;775-783.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 775-783
    • Strauer, B.1
  • 34
    • 0027177615 scopus 로고
    • Coronary vasodilator reserve in untreated and treated hypertensive patients with and without left ventricular hypertrophy
    • Antony I, Nitenberg A, Foult J, Aptecar E. Coronary vasodilator reserve in untreated and treated hypertensive patients with and without left ventricular hypertrophy. J Am Coll Cardiol. 22:1993;514-520.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 514-520
    • Antony, I.1    Nitenberg, A.2    Foult, J.3    Aptecar, E.4
  • 35
    • 0022498028 scopus 로고
    • Effects of previous myocardial infarction on measurements of reactive hyperemia and coronary vascular reserve
    • Klein L, Agarwal J, Schneider R, Herman G, Weintraub W, Helfant R. Effects of previous myocardial infarction on measurements of reactive hyperemia and coronary vascular reserve. J Am Coll Cardiol. 8:1986;357-363.
    • (1986) J Am Coll Cardiol , vol.8 , pp. 357-363
    • Klein, L.1    Agarwal, J.2    Schneider, R.3    Herman, G.4    Weintraub, W.5    Helfant, R.6
  • 36
    • 0020521308 scopus 로고
    • Angina caused by reduced vasodilator reserve of the small coronary arteries
    • Cannon RO III, Watson RM, Rosing DR, Epstein SE. Angina caused by reduced vasodilator reserve of the small coronary arteries. J Am Coll Cardiol. 1:1983;1359-1373.
    • (1983) J Am Coll Cardiol , vol.1 , pp. 1359-1373
    • Cannon R.O. III1    Watson, R.M.2    Rosing, D.R.3    Epstein, S.E.4
  • 37
    • 0025267947 scopus 로고
    • Recovery of a normal coronary vascular reserve after rejection therapy in acute human cardiac allograft rejection
    • Nitenberg A, Tavolaro O, Benvenuti C, et al. Recovery of a normal coronary vascular reserve after rejection therapy in acute human cardiac allograft rejection. Circulation. 81:1990;1312-1318.
    • (1990) Circulation , vol.81 , pp. 1312-1318
    • Nitenberg, A.1    Tavolaro, O.2    Benvenuti, C.3
  • 38
    • 0025187841 scopus 로고
    • Regional coronary blood flow velocity and vasodilatory reserve in patients with angiographically normal coronary arteries
    • Kern MJ, Tatineni S, Gudipati C, et al. Regional coronary blood flow velocity and vasodilatory reserve in patients with angiographically normal coronary arteries. Coron Artery Dis. 1:1990;579-589.
    • (1990) Coron Artery Dis , vol.1 , pp. 579-589
    • Kern, M.J.1    Tatineni, S.2    Gudipati, C.3
  • 39
    • 0029019339 scopus 로고
    • Long-term reproducibility of coronary flow velocity measurements in patients with coronary artery disease
    • Di Mario C, Gil R, Serruys PW. Long-term reproducibility of coronary flow velocity measurements in patients with coronary artery disease. Am J Cardiol. 75:1995;1177-1180.
    • (1995) Am J Cardiol , vol.75 , pp. 1177-1180
    • Di Mario, C.1    Gil, R.2    Serruys, P.W.3
  • 40
    • 0027397420 scopus 로고
    • The angle of incidence of the ultrasonic beam: A critical factor for the image quality in intravascular ultrasonography
    • DiMario C, Madretsma S, Linker D, et al. The angle of incidence of the ultrasonic beam a critical factor for the image quality in intravascular ultrasonography . Am Heart J. 125:1993;442-448.
    • (1993) Am Heart J , vol.125 , pp. 442-448
    • Dimario, C.1    Madretsma, S.2    Linker, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.