메뉴 건너뛰기




Volumn 43, Issue 4, 2000, Pages 549-558

A reduced field-of-view method to increase temporal resolution or reduce scan time in cine MRI

Author keywords

Cine imaging; Rapid imaging; Reduced FOV

Indexed keywords

CARDIAC IMAGING; CLASS OF METHODS; DYNAMIC APPLICATIONS; DYNAMIC CHANGES; FIELD OF VIEWS; RAPID IMAGING; REDUCED FOV; TEMPORAL RESOLUTION;

EID: 0034027218     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(200004)43:4<549::AID-MRM9>3.0.CO;2-Y     Document Type: Article
Times cited : (15)

References (19)
  • 2
    • 0024469533 scopus 로고
    • Retrospective cardiac gating: A review of technical aspects and future directions
    • Lenz GW, Haacke EM, White RD. Retrospective cardiac gating: a review of technical aspects and future directions. Magn Reson Imaging 1989; 7:445-455.
    • (1989) Magn Reson Imaging , vol.7 , pp. 445-455
    • Lenz, G.W.1    Haacke, E.M.2    White, R.D.3
  • 3
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci USA 1990;87:9868-9872.
    • (1990) Proc Natl Acad Sci USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 5
    • 0029029302 scopus 로고
    • Three-dimensional myocardial deformations: Calculation with displacement field fitting to tagged MR images
    • O'Dell WG, Moore CC, Hunter WC, Zerhouni EA, McVeigh ER. Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images. Radiology 1995;195:829-835.
    • (1995) Radiology , vol.195 , pp. 829-835
    • O'Dell, W.G.1    Moore, C.C.2    Hunter, W.C.3    Zerhouni, E.A.4    McVeigh, E.R.5
  • 8
    • 23744477998 scopus 로고    scopus 로고
    • Dynamic MR imaging of the breast combined with analysis of contrast agent kinetics in the differentiation of primary breast tumours
    • Mussurakis S, Buckley DL, Drew PJ, Fox JN, Carleton PJ, Turnbull LW, Horsman A. Dynamic MR imaging of the breast combined with analysis of contrast agent kinetics in the differentiation of primary breast tumours. Clin Radiol 1997;52:516-526.
    • (1997) Clin Radiol , vol.52 , pp. 516-526
    • Mussurakis, S.1    Buckley, D.L.2    Drew, P.J.3    Fox, J.N.4    Carleton, P.J.5    Turnbull, L.W.6    Horsman, A.7
  • 9
    • 0028364190 scopus 로고
    • Reduction of field of view for dynamic imaging
    • Hu X, Parrish T. Reduction of field of view for dynamic imaging. Magn Reson Med 1994;31:691-694.
    • (1994) Magn Reson Med , vol.31 , pp. 691-694
    • Hu, X.1    Parrish, T.2
  • 10
    • 0031400791 scopus 로고    scopus 로고
    • Implementation of a reduced field-of-view method for dynamic MR imaging using navigator echoes
    • Kyriakos WE, Panych LP, Zientara GP, Jolesz FA. Implementation of a reduced field-of-view method for dynamic MR imaging using navigator echoes. J Magn Reson Imaging 1997;7:376-381.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 376-381
    • Kyriakos, W.E.1    Panych, L.P.2    Zientara, G.P.3    Jolesz, F.A.4
  • 11
    • 0030012103 scopus 로고    scopus 로고
    • Temporal resolution improvement in dynamic imaging
    • Fredrickson JO, Pelc NJ. Temporal resolution improvement in dynamic imaging. Magn Reson Med 1996;35:621-625.
    • (1996) Magn Reson Med , vol.35 , pp. 621-625
    • Fredrickson, J.O.1    Pelc, N.J.2
  • 12
    • 0031850913 scopus 로고    scopus 로고
    • Reduced circular field-of-view imaging
    • Scheffler K, Hennig J. Reduced circular field-of-view imaging. Magn Reson Med 1996;40:474-480.
    • (1996) Magn Reson Med , vol.40 , pp. 474-480
    • Scheffler, K.1    Hennig, J.2
  • 13
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med 1999;42:813-828.
    • (1999) Magn Reson Med , vol.42 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 14
    • 0028222974 scopus 로고
    • Experimental study of the effects of "fractional" gating on flow measurements
    • Buonocore MH, Gao L. Experimental study of the effects of "fractional" gating on flow measurements. Magn Reson Med 1994;31:420-436.
    • (1994) Magn Reson Med , vol.31 , pp. 420-436
    • Buonocore, M.H.1    Gao, L.2
  • 16
    • 0022260368 scopus 로고
    • Respiratory ordered phase encoding (ROPE): A method for reducing respiratory motion artefacts in MR imaging
    • Bailes DR, Gilderdale DJ, Bydder GM, Collins AG, Firmin DN. Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. J Comput Assist Tomogr 1985;9: 835-838.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 835-838
    • Bailes, D.R.1    Gilderdale, D.J.2    Bydder, G.M.3    Collins, A.G.4    Firmin, D.N.5
  • 19
    • 0028393711 scopus 로고
    • Time-resolved MR imaging by automatic data segmentation
    • Frederickson JO, Pelc NJ. Time-resolved MR imaging by automatic data segmentation. J Magn Reson Imaging 1994;4:189-196.
    • (1994) J Magn Reson Imaging , vol.4 , pp. 189-196
    • Frederickson, J.O.1    Pelc, N.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.