메뉴 건너뛰기




Volumn 11, Issue 3, 2000, Pages 250-259

Ultra-fast three-dimensional MR perfusion imaging of the entire brain in acute stroke assessment

Author keywords

Diffusion; MRI, 3D; Perfusion; Stroke

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN PERFUSION; CLINICAL ARTICLE; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; FEMALE; FUNCTIONAL ASSESSMENT; HUMAN; IMAGE QUALITY; MALE; PRIORITY JOURNAL; SIGNAL NOISE RATIO; STROKE; THREE DIMENSIONAL IMAGING;

EID: 0034007014     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(200003)11:3<250::AID-JMRI3>3.0.CO;2-O     Document Type: Article
Times cited : (25)

References (38)
  • 1
    • 0032541845 scopus 로고    scopus 로고
    • Randomized double-blind placebo-controlled trial of thrombolytic therapy with intravenous alteplase in acute ischemic stroke (ECASS II)
    • Hacke W, Kaste M, Fieschi C, et al. Randomized double-blind placebo-controlled trial of thrombolytic therapy with intravenous alteplase in acute ischemic stroke (ECASS II). Lancet 1998;352: 1245-1251.
    • (1998) Lancet , vol.352 , pp. 1245-1251
    • Hacke, W.1    Kaste, M.2    Fieschi, C.3
  • 2
    • 0033549382 scopus 로고    scopus 로고
    • Early recanalisation in acute ischaemic stroke saves tissue at risk defined by MRI
    • Jansen O, Schellinger P, Fiebach J, Hacke W, Sartor K. Early recanalisation in acute ischaemic stroke saves tissue at risk defined by MRI. Lancet 1999;353:2036-2037.
    • (1999) Lancet , vol.353 , pp. 2036-2037
    • Jansen, O.1    Schellinger, P.2    Fiebach, J.3    Hacke, W.4    Sartor, K.5
  • 3
    • 0029807883 scopus 로고    scopus 로고
    • Evolving stroke and the ischemic penumbra
    • Fisher M, Garcia JH. Evolving stroke and the ischemic penumbra. Neurology 1996;47:884-888.
    • (1996) Neurology , vol.47 , pp. 884-888
    • Fisher, M.1    Garcia, J.H.2
  • 4
    • 0031752417 scopus 로고    scopus 로고
    • Prediction of stroke outcome with echo planar perfusion-and diffusion-weighted MRI
    • Barber PA, Darby DG, Desmonds PM, et al. Prediction of stroke outcome with echo planar perfusion-and diffusion-weighted MRI. Neurology 1998;51:418-426.
    • (1998) Neurology , vol.51 , pp. 418-426
    • Barber, P.A.1    Darby, D.G.2    Desmonds, P.M.3
  • 5
    • 0032946781 scopus 로고    scopus 로고
    • Absent middle cerebral artery flow predicts the presence and evolution of the ischemic penumbra
    • Barber PA, Davis SM, Darby DG, et al. Absent middle cerebral artery flow predicts the presence and evolution of the ischemic penumbra. Neurology 1999;52:1125-1132.
    • (1999) Neurology , vol.52 , pp. 1125-1132
    • Barber, P.A.1    Davis, S.M.2    Darby, D.G.3
  • 6
    • 0031981370 scopus 로고    scopus 로고
    • Regional ischemia and ischemic injury in patients with acute middle cerebral artery stroke as defined by early diffusion-weighted and perfusion-weighted MRI
    • Rordorf G, Koroshetz WJ, Copen WA, et al. Regional ischemia and ischemic injury in patients with acute middle cerebral artery stroke as defined by early diffusion-weighted and perfusion-weighted MRI. Stroke 1998;29:939-943.
    • (1998) Stroke , vol.29 , pp. 939-943
    • Rordorf, G.1    Koroshetz, W.J.2    Copen, W.A.3
  • 7
    • 0030906785 scopus 로고    scopus 로고
    • Clinical utility of diffusion-weighted magnetic resonance imaging in the assessment of ischemic stroke
    • Lutsep HL, Albers GW, DeCrespigny A, et al. Clinical utility of diffusion-weighted magnetic resonance imaging in the assessment of ischemic stroke. Ann Neurol 1997;41:574-580.
    • (1997) Ann Neurol , vol.41 , pp. 574-580
    • Lutsep, H.L.1    Albers, G.W.2    DeCrespigny, A.3
  • 8
    • 0031729295 scopus 로고    scopus 로고
    • Time course of lesion development in patients with acute stroke: Serial diffusion-and hemodynamic-weighted magnetic resonance imaging
    • Schwamm LH, Koroshetz WJ, Soerensen AG, et al. Time course of lesion development in patients with acute stroke: serial diffusion-and hemodynamic-weighted magnetic resonance imaging. Stroke 1998;29:2268-2276.
    • (1998) Stroke , vol.29 , pp. 2268-2276
    • Schwamm, L.H.1    Koroshetz, W.J.2    Soerensen, A.G.3
  • 9
    • 0031858307 scopus 로고    scopus 로고
    • MRI assessment of cerebral blood volume in patients with brain infarcts
    • Wu RH, Bruening R, Berchtenbreiter C, et al. MRI assessment of cerebral blood volume in patients with brain infarcts. Neuroradiology 1998;40:496-502.
    • (1998) Neuroradiology , vol.40 , pp. 496-502
    • Wu, R.H.1    Bruening, R.2    Berchtenbreiter, C.3
  • 10
    • 0031924087 scopus 로고    scopus 로고
    • Correlation of perfusion- and diffusion-weighted MRI with NIHISS score in acute (<6.5 h) ischemic stroke
    • Tong DC, Yenari MA, Albers GW, O'Brian M, Marks MP, Moseley ME. Correlation of perfusion-and diffusion-weighted MRI with NIHISS score in acute (<6.5 h) ischemic stroke. Neurology 1998; 50:864-870.
    • (1998) Neurology , vol.50 , pp. 864-870
    • Tong, D.C.1    Yenari, M.A.2    Albers, G.W.3    O'Brian, M.4    Marks, M.P.5    Moseley, M.E.6
  • 11
    • 13144258774 scopus 로고    scopus 로고
    • Improved diagnosis of early infarcts by the combined use of perfusion and diffusion-weighted imaging
    • Flacke S, Keller E, Hartmann A, et al. Improved diagnosis of early infarcts by the combined use of perfusion and diffusion-weighted imaging. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 1998;168:493-501.
    • (1998) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.168 , pp. 493-501
    • Flacke, S.1    Keller, E.2    Hartmann, A.3
  • 12
    • 0028791396 scopus 로고
    • A model to predict the histopathology of human stroke using diffusion and T2-weighted magnetic resonance imaging
    • Welch KM, Windham J, Knight RA, et al. A model to predict the histopathology of human stroke using diffusion and T2-weighted magnetic resonance imaging. Stroke 1995;26:1983-1989.
    • (1995) Stroke , vol.26 , pp. 1983-1989
    • Welch, K.M.1    Windham, J.2    Knight, R.A.3
  • 13
    • 0028543955 scopus 로고
    • Healthy and infarcted brain tissue studied at short diffusion times: The origins of apparent restriction and the reduction in apparent diffusion coefficient
    • Norris DG, Nierndorf T, Leibfritz D. Healthy and infarcted brain tissue studied at short diffusion times: the origins of apparent restriction and the reduction in apparent diffusion coefficient. NMR Biomed 1994;7:304-310.
    • (1994) NMR Biomed , vol.7 , pp. 304-310
    • Norris, D.G.1    Nierndorf, T.2    Leibfritz, D.3
  • 14
    • 0023847908 scopus 로고
    • Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effects
    • Villringer A, Rosen B, Belliveau JW, et al. Dynamic imaging with lanthanide chelates in normal brain: contrast due to magnetic susceptibility effects. Magn Reson Med 1988;6:164-174.
    • (1988) Magn Reson Med , vol.6 , pp. 164-174
    • Villringer, A.1    Rosen, B.2    Belliveau, J.W.3
  • 15
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: Numeric simulations and applications to cerebral physiology
    • Fisel CR, Ackerman JL, Buxton RB, et al. MR contrast due to microscopically heterogeneous magnetic susceptibility: numeric simulations and applications to cerebral physiology. Magn Reson Med 1991;17:336-347.
    • (1991) Magn Reson Med , vol.17 , pp. 336-347
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3
  • 17
    • 0000606319 scopus 로고
    • Theoretical basis of indicator-dilution methods for measuring blood flow and volume
    • Zierler KL. Theoretical basis of indicator-dilution methods for measuring blood flow and volume. Circ Res 1965;16:393-407.
    • (1965) Circ Res , vol.16 , pp. 393-407
    • Zierler, K.L.1
  • 18
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passage. Part I: Mathematical approach and statistical analysis
    • Ostergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passage. Part I: Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • Ostergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 19
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation: Theory and experiment
    • Weisskoff RM, Zuo CS, Boxerman JL, Rosen BR. Microscopic susceptibility variation and transverse relaxation: theory and experiment. Magn Reson Med 1994;31:601-610.
    • (1994) Magn Reson Med , vol.31 , pp. 601-610
    • Weisskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4
  • 20
    • 0032231310 scopus 로고    scopus 로고
    • Hemodynamic effects of middle cerebral artery stenosis and occlusion
    • Derdeyn CP, Powers WJ, Grubb RL. Hemodynamic effects of middle cerebral artery stenosis and occlusion. AJNR 1998;19:1463-1469.
    • (1998) AJNR , vol.19 , pp. 1463-1469
    • Derdeyn, C.P.1    Powers, W.J.2    Grubb, R.L.3
  • 21
    • 0027494434 scopus 로고
    • A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO)
    • Liu G, Sobering G, Duyn J, Moonen CTW. A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO). Magn Reson Med 1993;30:764-768.
    • (1993) Magn Reson Med , vol.30 , pp. 764-768
    • Liu, G.1    Sobering, G.2    Duyn, J.3    Moonen, C.T.W.4
  • 22
    • 0029112443 scopus 로고
    • Three-dimensional functional magnetic resonance imaging of human brain on a clinical 1.5-T scanner
    • van Gelderen P, Ramsey NF, Liu G, et al. Three-dimensional functional magnetic resonance imaging of human brain on a clinical 1.5-T scanner. Proc Natl Acad Sci USA 1995;18:6906-6910.
    • (1995) Proc Natl Acad Sci USA , vol.18 , pp. 6906-6910
    • Van Gelderen, P.1    Ramsey, N.F.2    Liu, G.3
  • 23
    • 0031019981 scopus 로고    scopus 로고
    • Reliability of the National Institutes of Health Stroke Scale: Extension to non-neurologists in the context of a clinical trial
    • Goldstein LB, Samsa GP. Reliability of the National Institutes of Health Stroke Scale: extension to non-neurologists in the context of a clinical trial. Stroke 1997;28:307-310.
    • (1997) Stroke , vol.28 , pp. 307-310
    • Goldstein, L.B.1    Samsa, G.P.2
  • 25
    • 0021948756 scopus 로고
    • Measurement of signal intensities in the presence of noise in MR images
    • Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985;12:232-233.
    • (1985) Med Phys , vol.12 , pp. 232-233
    • Henkelman, R.M.1
  • 26
    • 0030997814 scopus 로고    scopus 로고
    • Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to noise
    • Benner T, Heiland S, Erb G, Forsting M, Sator K. Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: influence of time resolution, maximal signal drop and signal-to noise. Magn Reson Imaging 1997;15:307-317.
    • (1997) Magn Reson Imaging , vol.15 , pp. 307-317
    • Benner, T.1    Heiland, S.2    Erb, G.3    Forsting, M.4    Sator, K.5
  • 27
    • 0031747954 scopus 로고    scopus 로고
    • Arterial territories of the human brain: Cerebral hemispheres
    • Tatu L, MoulinT, Bogousslavsky J, Duvernoy H. Arterial territories of the human brain: cerebral hemispheres. Neurology 1998;50: 1699-1708.
    • (1998) Neurology , vol.50 , pp. 1699-1708
    • Tatu, L.1    Moulin, T.2    Bogousslavsky, J.3    Duvernoy, H.4
  • 28
    • 0032602663 scopus 로고    scopus 로고
    • Echo-planar perfusion imaging with high spatial and temporal resolution: Methodology and clinical aspects
    • Bitzer M, Klose U, Naegele T, et al. Echo-planar perfusion imaging with high spatial and temporal resolution: methodology and clinical aspects. Eur Radiol 1999;9:221-229.
    • (1999) Eur Radiol , vol.9 , pp. 221-229
    • Bitzer, M.1    Klose, U.2    Naegele, T.3
  • 29
    • 0032936419 scopus 로고    scopus 로고
    • Correlation of regional cerebral blood flow from perfusion MRI and SPECT in normal subjects
    • Ernst T, Chang L, Itti L, Speck O. Correlation of regional cerebral blood flow from perfusion MRI and SPECT in normal subjects. Magn Reson Imaging 1999;17:349-354.
    • (1999) Magn Reson Imaging , vol.17 , pp. 349-354
    • Ernst, T.1    Chang, L.2    Itti, L.3    Speck, O.4
  • 30
  • 34
    • 0032952199 scopus 로고    scopus 로고
    • A standardized MRI stroke protocol: Comparison with CT in hyperacute intracerebral hemorrhage
    • Schellinger PD, Jansen O, Fiebach JB, Hacke W, Sartor K. A standardized MRI stroke protocol: comparison with CT in hyperacute intracerebral hemorrhage. Stroke 1999;30:765-768.
    • (1999) Stroke , vol.30 , pp. 765-768
    • Schellinger, P.D.1    Jansen, O.2    Fiebach, J.B.3    Hacke, W.4    Sartor, K.5
  • 35
    • 0029940733 scopus 로고    scopus 로고
    • Hyperacute stroke: Evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging
    • Soerensen AG, Buonanna FS, Gonzalez RG, et al. Hyperacute stroke: evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging. Radiology 1996;199:391-401.
    • (1996) Radiology , vol.199 , pp. 391-401
    • Soerensen, A.G.1    Buonanna, F.S.2    Gonzalez, R.G.3
  • 36
    • 0031797298 scopus 로고    scopus 로고
    • Correlation of MR imaging-determined cerebral blood volume maps with histologic and angiographic determination of vascularity of gliomas
    • Sugahara T, Korogi Y, Kochi M, et al. Correlation of MR imaging-determined cerebral blood volume maps with histologic and angiographic determination of vascularity of gliomas. AJR 1998;171: 1479-1486.
    • (1998) AJR , vol.171 , pp. 1479-1486
    • Sugahara, T.1    Korogi, Y.2    Kochi, M.3
  • 37
    • 0000174732 scopus 로고    scopus 로고
    • Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: Comparison with positron emission tomography values
    • Ostergaard L, Smith DF, Vestergaard-Poulsen P, et al. Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: comparison with positron emission tomography values. Cereb Blood Flow Metab 1998;18:425-432.
    • (1998) Cereb Blood Flow Metab , vol.18 , pp. 425-432
    • Ostergaard, L.1    Smith, D.F.2    Vestergaard-Poulsen, P.3
  • 38
    • 0032935323 scopus 로고    scopus 로고
    • Quantitative analysis of cerebral microvascular hemodynamics with T2-weighted dynamic MR imaging
    • Koshimoto Y, Yamada H, Kimura H et al. Quantitative analysis of cerebral microvascular hemodynamics with T2-weighted dynamic MR imaging. J Magn Reson Imaging 1999;9:462-467.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 462-467
    • Koshimoto, Y.1    Yamada, H.2    Kimura, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.