메뉴 건너뛰기




Volumn 21, Issue 1, 2000, Pages 80-98

Real-time magnetic resonance imaging: Diagnostic and interventional applications

Author keywords

Angioplasty; Fluoroscopy; Interventional; Magnetic resonance imaging; Radiofrequency ablation; Stents

Indexed keywords

BALLOON CATHETER; CARDIOVASCULAR DISEASE; CATHETER ABLATION; DIAGNOSTIC IMAGING; DIAGNOSTIC VALUE; HEART ARRHYTHMIA; HEART ELECTROPHYSIOLOGY; HUMAN; INTERVENTIONAL RADIOLOGY; INTRAVASCULAR CATHETER; NUCLEAR MAGNETIC RESONANCE IMAGING; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; RADIOFREQUENCY RADIATION; REVIEW; SAFETY; STENT; TECHNIQUE; THERAPY;

EID: 0033956227     PISSN: 01720643     EISSN: None     Source Type: Journal    
DOI: 10.1007/s002469910010     Document Type: Review
Times cited : (58)

References (76)
  • 1
    • 0023279203 scopus 로고
    • Instant images of the human heart using a new whole-body MR imaging system
    • Rzedizan RR, Pykett IL (1987) Instant images of the human heart using a new whole-body MR imaging system. AJR Am J Roentgenol 149:245-250
    • (1987) AJR Am J Roentgenol , vol.149 , pp. 245-250
    • Rzedizan, R.R.1    Pykett, I.L.2
  • 8
    • 0032965738 scopus 로고    scopus 로고
    • Multiecho segmented k-space imaging: An optimized hybrid sequence for ultrafast cardiac imaging
    • Reeder SB, Atalar E, Faranesh AZ, McVeigh ER (1999) Multiecho segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging. Magn Reson Med 41:375-385
    • (1999) Magn Reson Med , vol.41 , pp. 375-385
    • Reeder, S.B.1    Atalar, E.2    Faranesh, A.Z.3    McVeigh, E.R.4
  • 9
    • 0028364190 scopus 로고
    • Reduction of field of view for dynamic imaging
    • Hu X, Parrish T (1994) Reduction of field of view for dynamic imaging. Magn Reson Med 31:691-694
    • (1994) Magn Reson Med , vol.31 , pp. 691-694
    • Hu, X.1    Parrish, T.2
  • 11
    • 0030884045 scopus 로고    scopus 로고
    • Real-time interactive MRI on a conventional scanner
    • Kerr AB, Pauly JM, Hu BS, et al. (1997) Real-time interactive MRI on a conventional scanner. Magn Reson Med 38:355-367
    • (1997) Magn Reson Med , vol.38 , pp. 355-367
    • Kerr, A.B.1    Pauly, J.M.2    Hu, B.S.3
  • 13
    • 0029907019 scopus 로고    scopus 로고
    • Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions
    • Bakker CJ. Hoogeveen RM, Weber J, van Vaals JJ, Viergever MA, Mali WP (1996) Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions. Magn Reson Med 36:816-820
    • (1996) Magn Reson Med , vol.36 , pp. 816-820
    • Bakker, C.J.1    Hoogeveen, R.M.2    Weber, J.3    Van Vaals, J.J.4    Viergever, M.A.5    Mali, W.P.6
  • 17
    • 0028288337 scopus 로고
    • Vascular interventions guided by ultrafast MR imaging: Evaluation of different materials
    • Kochii VD, McKinnon GC, Hofmann E, von Schulthess GK (1994) Vascular interventions guided by ultrafast MR imaging: evaluation of different materials. Magn Reson Med 31:309-314
    • (1994) Magn Reson Med , vol.31 , pp. 309-314
    • Kochii, V.D.1    McKinnon, G.C.2    Hofmann, E.3    Von Schulthess, G.K.4
  • 18
    • 0027399141 scopus 로고
    • Real-time position monitoring of invasive devices using magnetic resonance
    • Dumoulin CL, Souza SP, Darrow RD (1993) Real-time position monitoring of invasive devices using magnetic resonance. Magn Reson Med 29:411-415
    • (1993) Magn Reson Med , vol.29 , pp. 411-415
    • Dumoulin, C.L.1    Souza, S.P.2    Darrow, R.D.3
  • 22
    • 0031909104 scopus 로고    scopus 로고
    • Target definition and trajectory optimization for interactive MR-guided biopsies of brain tumors in an open configuration MRI system
    • Kollias SS, Bernays R, Manugg RA, Romanowski B, Yonekawa Y, Valavanis A (1998) Target definition and trajectory optimization for interactive MR-guided biopsies of brain tumors in an open configuration MRI system. J Magn Reson Imaging 8:143-159
    • (1998) J Magn Reson Imaging , vol.8 , pp. 143-159
    • Kollias, S.S.1    Bernays, R.2    Manugg, R.A.3    Romanowski, B.4    Yonekawa, Y.5    Valavanis, A.6
  • 24
    • 0031886372 scopus 로고    scopus 로고
    • Predictability of the size of laser-induced lesions in T1-weighted MR images obtained during interstitial laser-induced thermotherapy of benign prostatic hyperplasia
    • Mueller-Lisse UG, Heuck AF, Thoma M, Muschter R, Schneede P, Weninger E, Faber S, Hofstetter A, Reiser MF (1998) Predictability of the size of laser-induced lesions in T1-weighted MR images obtained during interstitial laser-induced thermotherapy of benign prostatic hyperplasia. J Magn Reson Imaging 8:31-39
    • (1998) J Magn Reson Imaging , vol.8 , pp. 31-39
    • Mueller-Lisse, U.G.1    Heuck, A.F.2    Thoma, M.3    Muschter, R.4    Schneede, P.5    Weninger, E.6    Faber, S.7    Hofstetter, A.8    Reiser, M.F.9
  • 25
    • 0031934807 scopus 로고    scopus 로고
    • Interactive MRI-guided radiofrequency interstitial theraml ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility
    • Lewin JS, Connell CF, Duerk JL, Chung Y, Clampitt ME, Spisak J, Gazelle GS, Haaga JR (1998) Interactive MRI-guided radiofrequency interstitial theraml ablation of abdominal tumors: clinical trial for evaluation of safety and feasibility. J Magn Reson Imaging 8:40-47
    • (1998) J Magn Reson Imaging , vol.8 , pp. 40-47
    • Lewin, J.S.1    Connell, C.F.2    Duerk, J.L.3    Chung, Y.4    Clampitt, M.E.5    Spisak, J.6    Gazelle, G.S.7    Haaga, J.R.8
  • 31
    • 0031884051 scopus 로고    scopus 로고
    • Ultimate intrinsic signal-to-noise ratio in MRI
    • Atalar E, Ocali O (1998) Ultimate intrinsic signal-to-noise ratio in MRI. Magn Reson Med 39:462-473
    • (1998) Magn Reson Med , vol.39 , pp. 462-473
    • Atalar, E.1    Ocali, O.2
  • 33
    • 0026534199 scopus 로고
    • Intravascular (catheter) NMR receiver probe: Preliminary design analysis and application to canine iliofemoral imaging
    • Hurst GC, Hua J, Duerk JL, Cohen AM (1992) Intravascular (catheter) NMR receiver probe: preliminary design analysis and application to canine iliofemoral imaging. Magn Reson Med 24:343-357
    • (1992) Magn Reson Med , vol.24 , pp. 343-357
    • Hurst, G.C.1    Hua, J.2    Duerk, J.L.3    Cohen, A.M.4
  • 35
    • 0021285166 scopus 로고
    • In vivo 3 lp nuclear magnetic resonance measurements in canine heart using a cathetercoil
    • Kantor HL, Briggs RW, Balaban RS (1984) In vivo 3 lp nuclear magnetic resonance measurements in canine heart using a cathetercoil. Circ Res 55:261-266
    • (1984) Circ Res , vol.55 , pp. 261-266
    • Kantor, H.L.1    Briggs, R.W.2    Balaban, R.S.3
  • 38
    • 0342718489 scopus 로고
    • Performance comparison of several coil geometries for use in catheters
    • McDonald GG, Chwialkowski M, Pershock RM (1992) Performance comparison of several coil geometries for use in catheters. Radiology 189:319
    • (1992) Radiology , vol.189 , pp. 319
    • McDonald, G.G.1    Chwialkowski, M.2    Pershock, R.M.3
  • 39
    • 0031023708 scopus 로고    scopus 로고
    • Intravascular magnetic resonance imaging using a loopless catheter antenna
    • Ocali O, Atalar E (1997) Intravascular magnetic resonance imaging using a loopless catheter antenna. Magn Reson Med 37:112-118
    • (1997) Magn Reson Med , vol.37 , pp. 112-118
    • Ocali, O.1    Atalar, E.2
  • 40
    • 0030812957 scopus 로고    scopus 로고
    • Intravascular MR imaging of atherosclerotic plaque: Ex vivo analysis of human femoral arteries with histologic correlation
    • Zimmermann GG, Erhart P, Schneider J, von Schulthess GK, Schmidt M, Debatin JF (1997) Intravascular MR imaging of atherosclerotic plaque: ex vivo analysis of human femoral arteries with histologic correlation. Radiology 204:769-774
    • (1997) Radiology , vol.204 , pp. 769-774
    • Zimmermann, G.G.1    Erhart, P.2    Schneider, J.3    Von Schulthess, G.K.4    Schmidt, M.5    Debatin, J.F.6
  • 41
    • 0033514988 scopus 로고    scopus 로고
    • High-resolution intravascular magnetic resonance imaging monitoring of plaque formation in heritable hyperlipidemic rabbits
    • Zimmermann-Paul GG, Quick HH, Vogt P, von Schulthess GK, Kling D, Debatin IF (1999) High-resolution intravascular magnetic resonance imaging monitoring of plaque formation in heritable hyperlipidemic rabbits. Circulation 99:1054-1061
    • (1999) Circulation , vol.99 , pp. 1054-1061
    • Zimmermann-Paul, G.G.1    Quick, H.H.2    Vogt, P.3    Von Schulthess, G.K.4    Kling, D.5    Debatin, I.F.6
  • 43
    • 0342718486 scopus 로고    scopus 로고
    • High-resolution transesophageal magnetic resonance imaging of linear atrial radiofrequency ablation lesions
    • Lardo AC, McVeigh ER, Berger RD, Calkins H, Lima J, Halperin HR (1999) High-resolution transesophageal magnetic resonance imaging of linear atrial radiofrequency ablation lesions, (abstract) PACE
    • (1999) PACE
    • Lardo, A.C.1    McVeigh, E.R.2    Berger, R.D.3    Calkins, H.4    Lima, J.5    Halperin, H.R.6
  • 45
    • 0031910940 scopus 로고    scopus 로고
    • MR-guided balloon angioplasty: In vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions
    • Bakker CJ, Smits HF, Bos C, et al. MR-guided balloon angioplasty: in vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions. JMRI 8: 245-250
    • JMRI , vol.8 , pp. 245-250
    • Bakker, C.J.1    Smits, H.F.2    Bos, C.3
  • 47
    • 0031794598 scopus 로고    scopus 로고
    • Intravascular MR monitored balloon angioplasty: An in vivo feasibility study
    • Yang X, Bradley D, Bolster J, Kraitchman DL, Atalar E (1998) Intravascular MR monitored balloon angioplasty: an in vivo feasibility study. JVIR 9:953-959
    • (1998) JVIR , vol.9 , pp. 953-959
    • Yang, X.1    Bradley, D.2    Bolster, J.3    Kraitchman, D.L.4    Atalar, E.5
  • 48
    • 0023875003 scopus 로고
    • Balloon expandable intravascular stent
    • Palmaz JC (1988) Balloon expandable intravascular stent. AJR Am J Roentgenol 150:1263-1269
    • (1988) AJR Am J Roentgenol , vol.150 , pp. 1263-1269
    • Palmaz, J.C.1
  • 51
    • 0020039354 scopus 로고
    • Catheter technique for closed-chest ablation of the atrioventricular conduction system: A therapeutic alternative for the treatment of refractory supraventricular tachycardia
    • Gallagher JJ. Svenson RH, Kasell JH, German LD, Bardy GH, Broughton A, Critelli G (1982) Catheter technique for closed-chest ablation of the atrioventricular conduction system: a therapeutic alternative for the treatment of refractory supraventricular tachycardia. N Engl J Med 306:194-200
    • (1982) N Engl J Med , vol.306 , pp. 194-200
    • Gallagher, J.J.1    Svenson, R.H.2    Kasell, J.H.3    German, L.D.4    Bardy, G.H.5    Broughton, A.6    Critelli, G.7
  • 52
    • 0027179535 scopus 로고
    • Role of radiofrequency ablation in the management of supraventricular arrhythmias: Experience in 760 consecutive patients
    • Kay GN, Epstein AE, Dailey SM, Plumb VJ (1993) Role of radiofrequency ablation in the management of supraventricular arrhythmias: experience in 760 consecutive patients. J Cardiovasc Electrophysiol 4:371-389
    • (1993) J Cardiovasc Electrophysiol , vol.4 , pp. 371-389
    • Kay, G.N.1    Epstein, A.E.2    Dailey, S.M.3    Plumb, V.J.4
  • 53
    • 0025767995 scopus 로고
    • Diagnosis and cure of the Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardias during a single electrophysiology test
    • Calkins H, Sousa J, El-Atassi R, Rosenheck S, DeBuitleir M, Kou WH, Radish AH, Langberg JJ, Morady F (1991) Diagnosis and cure of the Wolff-Parkinson-White syndrome or paroxysmal supraventricular tachycardias during a single electrophysiology test. N Engl J Med 324:1612-1618
    • (1991) N Engl J Med , vol.324 , pp. 1612-1618
    • Calkins, H.1    Sousa, J.2    El-Atassi, R.3    Rosenheck, S.4    DeBuitleir, M.5    Kou, W.H.6    Radish, A.H.7    Langberg, J.J.8    Morady, F.9
  • 55
    • 0026656298 scopus 로고
    • Radiofrequency catheter ablation for the treatment of human type I atrial flutter: Identification of a critical zone in the reentrant circuit by endocardial mapping techniques
    • Feld GK, Fleck RP, Chen P-S, Boyce K, Bahnson TD, Stein JB, Calisi CM, Ibarra M (1992) Radiofrequency catheter ablation for the treatment of human type I atrial flutter: identification of a critical zone in the reentrant circuit by endocardial mapping techniques. Circulation 86:1233-1240
    • (1992) Circulation , vol.86 , pp. 1233-1240
    • Feld, G.K.1    Fleck, R.P.2    Chen, P.-S.3    Boyce, K.4    Bahnson, T.D.5    Stein, J.B.6    Calisi, C.M.7    Ibarra, M.8
  • 56
    • 0001754856 scopus 로고
    • A catheter-based curative approach to atrial fibrillation in humans
    • abstract
    • Swartz JF, Pellersels G, Silvers J, Pattern L, Cervantez D (1994) A catheter-based curative approach to atrial fibrillation in humans. Circulation 90(Suppl I):I-335 (abstract)
    • (1994) Circulation , vol.90 , Issue.SUPPL. I
    • Swartz, J.F.1    Pellersels, G.2    Silvers, J.3    Pattern, L.4    Cervantez, D.5
  • 59
    • 0343153066 scopus 로고    scopus 로고
    • Catheter placement and high fidelity electrophysiologic signal acquisition during magnetic resonance imaging
    • Halperin HR, Lardo AC, McVeigh ER, Calkins H, Lima J, Berger RD (1999) Catheter placement and high fidelity electrophysiologic signal acquisition during magnetic resonance imaging. PACE
    • (1999) PACE
    • Halperin, H.R.1    Lardo, A.C.2    McVeigh, E.R.3    Calkins, H.4    Lima, J.5    Berger, R.D.6
  • 60
    • 0031001267 scopus 로고    scopus 로고
    • Biophysical characteristics of radiofrequency lesion formation in vivo: Dynamics of catheter tip-tissue contact evaluated by intracardiac echocardiography
    • Kalman JM, Fitzpatrick AP, Olgin JE, Chin MC, Lee RJ, Scheinman MM, Lesh MD (1997) Biophysical characteristics of radiofrequency lesion formation in vivo: dynamics of catheter tip-tissue contact evaluated by intracardiac echocardiography. Am Hrt J 133: 8-18
    • (1997) Am Hrt J , vol.133 , pp. 8-18
    • Kalman, J.M.1    Fitzpatrick, A.P.2    Olgin, J.E.3    Chin, M.C.4    Lee, R.J.5    Scheinman, M.M.6    Lesh, M.D.7
  • 61
    • 0342283502 scopus 로고    scopus 로고
    • Transesophageal magnetic resonance imaging can quantify gaps in discontinuous atrial radiofrequency lesions
    • in press
    • Lardo AC, McVeigh ER, Berger RD, Calkins H, Fried N, Halperin HR (1999) Transesophageal magnetic resonance imaging can quantify gaps in discontinuous atrial radiofrequency lesions. Circulation (in press)
    • (1999) Circulation
    • Lardo, A.C.1    McVeigh, E.R.2    Berger, R.D.3    Calkins, H.4    Fried, N.5    Halperin, H.R.6
  • 62
    • 0031593040 scopus 로고    scopus 로고
    • Accelerated arteriosclerosis after transplantation: The possible role of calcium channel blockers
    • Atkinson JB (1997) Accelerated arteriosclerosis after transplantation: the possible role of calcium channel blockers. Int J Cardiol 62(Suppl 2):S125-S134
    • (1997) Int J Cardiol , vol.62 , Issue.SUPPL. 2
    • Atkinson, J.B.1
  • 67
    • 0018372786 scopus 로고
    • Coarctation, tubular hypoplasia and the ductus arteriosus: Histological study of 35 speciments
    • Ho SY, Anderson RH (1979) Coarctation, tubular hypoplasia and the ductus arteriosus: histological study of 35 speciments. Br Heart J 41:268-214
    • (1979) Br Heart J , vol.41 , pp. 268-1214
    • Ho, S.Y.1    Anderson, R.H.2
  • 68
    • 0025309675 scopus 로고
    • Balloon angioplasty for the treatment of native coarctation: Results of valvuloplasty and angioplasty of congenital anomalies registry
    • Tynan M, Finley JP, Fontes V, Hess J, Kan J (1990) Balloon angioplasty for the treatment of native coarctation: results of Valvuloplasty and Angioplasty of Congenital Anomalies Registry. Am J Cardiol 65:790-792
    • (1990) Am J Cardiol , vol.65 , pp. 790-792
    • Tynan, M.1    Finley, J.P.2    Fontes, V.3    Hess, J.4    Kan, J.5
  • 69
    • 0028863117 scopus 로고
    • Balloon valvotomy for critical stenosis or atresia of pulmonary valve in newborns
    • Gournay V, Piechaud J, Delogu A, Sidi D, Kachaner J (1995) Balloon valvotomy for critical stenosis or atresia of pulmonary valve in newborns. J Am Coll Cardiol 26:1725-1731
    • (1995) J Am Coll Cardiol , vol.26 , pp. 1725-1731
    • Gournay, V.1    Piechaud, J.2    Delogu, A.3    Sidi, D.4    Kachaner, J.5
  • 70
    • 0028836418 scopus 로고
    • Determinants of successful balloon valvotomy in infants with critical pulmonary stenosis or membranous pulmonary atresia with intact ventricular septum
    • Fedderly RT, Lloyd TR, Mendelsohn AM, Beekman RH (1995) Determinants of successful balloon valvotomy in infants with critical pulmonary stenosis or membranous pulmonary atresia with intact ventricular septum. J Am Coll Cardiol 25:460-465
    • (1995) J Am Coll Cardiol , vol.25 , pp. 460-465
    • Fedderly, R.T.1    Lloyd, T.R.2    Mendelsohn, A.M.3    Beekman, R.H.4
  • 71
    • 0020529939 scopus 로고
    • Balloon dilation angioplasty of hypoplastic and stenotic pulmonary arteries
    • Lock JE, Castaneda-Zuniga WR, Fuhrman BP, Bass JL (1983) Balloon dilation angioplasty of hypoplastic and stenotic pulmonary arteries. Circulation 67:962-967
    • (1983) Circulation , vol.67 , pp. 962-967
    • Lock, J.E.1    Castaneda-Zuniga, W.R.2    Fuhrman, B.P.3    Bass, J.L.4
  • 73
    • 24844449778 scopus 로고    scopus 로고
    • Evaluation of aortic disease by non-invasive MR measurement of vessel wall distensibility
    • Relvas MS, Bolster BD, Hardy CJ, Zerhouni EA (1999) Evaluation of aortic disease by non-invasive MR measurement of vessel wall distensibility. (abstact) J Magn Reson Imaging 4:S30
    • (1999) J Magn Reson Imaging , vol.4
    • Relvas, M.S.1    Bolster, B.D.2    Hardy, C.J.3    Zerhouni, E.A.4
  • 74
    • 0003306009 scopus 로고
    • Nonlinear atrial radiofrequency lesions are arrhythmogenic: A study of skipped lesions in the normal atria
    • Avitall B, Helms RW, Chiang W, Periman BA (1995) Nonlinear atrial radiofrequency lesions are arrhythmogenic: a study of skipped lesions in the normal atria. Circulation 92(Suppl I):I-265
    • (1995) Circulation , vol.92 , Issue.SUPPL. I
    • Avitall, B.1    Helms, R.W.2    Chiang, W.3    Periman, B.A.4
  • 75
    • 0019785136 scopus 로고
    • Nuclear magnetic resonance (NR) in vitro studies: Known thresholds for health effects
    • Budinger TF (1981) Nuclear magnetic resonance (NR) in vitro studies: known thresholds for health effects. J Comput Assist Tomogr 5:800-811
    • (1981) J Comput Assist Tomogr , vol.5 , pp. 800-811
    • Budinger, T.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.