메뉴 건너뛰기




Volumn 41, Issue 2, 1999, Pages 375-385

Multi-echo segmented k-space imaging: An optimized hybrid sequence for ultrafast cardiac imaging

Author keywords

Cardiac imaging; Echo planar imaging; Fast imaging; Gradient echo imaging; Magnetic resonance (MR); Perfusion; Stress testing

Indexed keywords

CHEMICAL SHIFT; COMPUTERIZED TOMOGRAPHY; HEART; MAGNETIC RESONANCE IMAGING;

EID: 0032965738     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(199902)41:2<375::AID-MRM23>3.0.CO;2-Z     Document Type: Article
Times cited : (65)

References (32)
  • 1
    • 0025269066 scopus 로고
    • First-pass cardiac profusion: Evaluation with ultrafast MR imaging
    • Atkinson DJ, Burstein D, Edelman RR. First-pass cardiac profusion: evaluation with ultrafast MR imaging. Radiology 1990;174:757-762.
    • (1990) Radiology , vol.174 , pp. 757-762
    • Atkinson, D.J.1    Burstein, D.2    Edelman, R.R.3
  • 2
    • 0026013524 scopus 로고
    • Ultrafast magnetic resonance imaging: Diffusion and perfusion
    • Moseley ME, Sevick R, Woodland MF, et al. Ultrafast magnetic resonance imaging: diffusion and perfusion. Can Assoc Radiol J 1991;42:31-38.
    • (1991) Can Assoc Radiol J , vol.42 , pp. 31-38
    • Moseley, M.E.1    Sevick, R.2    Woodland, M.F.3
  • 4
    • 0028195043 scopus 로고
    • Contrast-enhanced echo-planar MR imaging of myocardial perfusion: Preliminary study in humans
    • Edelman RR, Li W. Contrast-enhanced echo-planar MR imaging of myocardial perfusion: preliminary study in humans. Radiology 1994: 190:771-777.
    • (1994) Radiology , vol.190 , pp. 771-777
    • Edelman, R.R.1    Li, W.2
  • 8
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin-echoes
    • Mansfield P. Multi-planar image formation using NMR spin-echoes. J Phys Chem 1977;10:L55-L58.
    • (1977) J Phys Chem , vol.10
    • Mansfield, P.1
  • 9
    • 0022872540 scopus 로고
    • RARE imaging: A fast imaging method for clinical MR
    • Hennig J, Nauerth A, Friedburg H, RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 1986;3:823-833.
    • (1986) Magn Reson Med , vol.3 , pp. 823-833
    • Hennig, J.1    Nauerth, A.2    Friedburg, H.3
  • 10
    • 0025783488 scopus 로고
    • GRASE (Gradient- and spin-echo) imaging: A novel fast MRI technique
    • Oshio K, Feinberg DA. GRASE (Gradient- and spin-echo) imaging: a novel fast MRI technique. Magn Reson Med 1991;20:344-349.
    • (1991) Magn Reson Med , vol.20 , pp. 344-349
    • Oshio, K.1    Feinberg, D.A.2
  • 11
    • 0027375577 scopus 로고
    • Ultrafast interleaved gradient-echo-planar imaging on a standard scanner
    • McKinnon GC. Ultrafast interleaved gradient-echo-planar imaging on a standard scanner. Magn Reson Med 1993;30:606-616.
    • (1993) Magn Reson Med , vol.30 , pp. 606-616
    • McKinnon, G.C.1
  • 12
    • 0028113844 scopus 로고
    • The effect of high performance gradients on fast gradient echo imaging
    • Reeder SB, McVeigh ER. The effect of high performance gradients on fast gradient echo imaging. Magn Reson Med 1994;32:612-621.
    • (1994) Magn Reson Med , vol.32 , pp. 612-621
    • Reeder, S.B.1    McVeigh, E.R.2
  • 13
    • 0028950554 scopus 로고
    • Multi-shot EPI for improvement of myocardial tag contrast: Comparison with segmented SPGR
    • Tang C, McVeigh ER, Zerhouni EA. Multi-shot EPI for improvement of myocardial tag contrast: comparison with segmented SPGR. Magn Reson Med 1995;33:443-447.
    • (1995) Magn Reson Med , vol.33 , pp. 443-447
    • Tang, C.1    McVeigh, E.R.2    Zerhouni, E.A.3
  • 14
    • 0031862930 scopus 로고    scopus 로고
    • In vivo measurement of T2* and field inhomngeneity maps in the human heart at 1.5 T
    • Reeder SB, Faranesh AZ, Boxerman JL, McVeigh ER. In vivo measurement of T2* and field inhomngeneity maps in the human heart at 1.5 T. Magn Reson Med 1998;39:988-998.
    • (1998) Magn Reson Med , vol.39 , pp. 988-998
    • Reeder, S.B.1    Faranesh, A.Z.2    Boxerman, J.L.3    McVeigh, E.R.4
  • 15
    • 0028117082 scopus 로고
    • Minimization of dead-periods in MRI pulse sequences for imaging oblique planes
    • Atalar E, McVeigh ER. Minimization of dead-periods in MRI pulse sequences for imaging oblique planes. Magn Reson Med 1994;32:773-777.
    • (1994) Magn Reson Med , vol.32 , pp. 773-777
    • Atalar, E.1    McVeigh, E.R.2
  • 16
    • 0026247679 scopus 로고
    • Theoretical aspects of motion sensitivity and compensation in echo-planar imaging
    • Duerk JL, Simonetti OP. Theoretical aspects of motion sensitivity and compensation in echo-planar imaging. J Magn Reson Imaging 1991;1: 643-650.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 643-650
    • Duerk, J.L.1    Simonetti, O.P.2
  • 17
    • 0025298010 scopus 로고
    • Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging
    • Farzaneh F, Riederer SJ, Pelc NJ. Analysis of T2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging. Magn Reson Med 1990;14:123-139.
    • (1990) Magn Reson Med , vol.14 , pp. 123-139
    • Farzaneh, F.1    Riederer, S.J.2    Pelc, N.J.3
  • 18
    • 0029879895 scopus 로고    scopus 로고
    • MRI of myocardial function: Motion tracking techniques (Review)
    • McVeigh ER. MRI of myocardial function: motion tracking techniques (Review). Magn Reson Imaging 1996;14:137-150.
    • (1996) Magn Reson Imaging , vol.14 , pp. 137-150
    • McVeigh, E.R.1
  • 19
    • 0000114910 scopus 로고
    • Gradient echo shifting in fast MRI techniques (GRASE imaging) for correction of field inhomogeneity errors and chemical shift
    • Feinberg DA, Oshio K. Gradient echo shifting in fast MRI techniques (GRASE imaging) for correction of field inhomogeneity errors and chemical shift. J Magn Reson 1992;97:177-183.
    • (1992) J Magn Reson , vol.97 , pp. 177-183
    • Feinberg, D.A.1    Oshio, K.2
  • 20
    • 0030924013 scopus 로고    scopus 로고
    • Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging
    • Reeder SB, Atalar E, Bolster BDJ, McVeigh ER. Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging. Magn Reson Med 1997;38:429-439.
    • (1997) Magn Reson Med , vol.38 , pp. 429-439
    • Reeder, S.B.1    Atalar, E.2    Bolster, B.D.J.3    McVeigh, E.R.4
  • 21
    • 0026601923 scopus 로고
    • Image reconstruction for echo planar imaging with nonequidistant k-space sampling
    • Bruder H, Fischer H, Reinfelder HE, Schmitt F. Image reconstruction for echo planar imaging with nonequidistant k-space sampling. Magn Reson Med 1992;23:311-323.
    • (1992) Magn Reson Med , vol.23 , pp. 311-323
    • Bruder, H.1    Fischer, H.2    Reinfelder, H.E.3    Schmitt, F.4
  • 22
    • 0344916617 scopus 로고
    • Precision of tag position estimation in breath-hold cine MRI: The effect of tag spacing
    • New York
    • McVeigh ER, Gao L. Precision of tag position estimation in breath-hold cine MRI: the effect of tag spacing. In: Proceedings of the SMRM, Twelfth Annual Meeting. New York, 1993. p. 199.
    • (1993) Proceedings of the SMRM, Twelfth Annual Meeting , pp. 199
    • McVeigh, E.R.1    Gao, L.2
  • 23
    • 0024987905 scopus 로고
    • A DANTE tagging sequence for the evaluation of translational sample motion
    • Mosher TJ, Smith MB. A DANTE tagging sequence for the evaluation of translational sample motion. Magn Reson Med 1990;15:334-339.
    • (1990) Magn Reson Med , vol.15 , pp. 334-339
    • Mosher, T.J.1    Smith, M.B.2
  • 24
    • 0024318208 scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • Axel L, Dougherty L. MR imaging of motion with spatial modulation of magnetization. Radiology 1989;171:841-845.
    • (1989) Radiology , vol.171 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 25
    • 0031848273 scopus 로고    scopus 로고
    • Precision of myocardial contour estimation from tagged MR images with a "black-blood" technique
    • Croisille P. Guttman MA, Atalar E. McVeigh ER, Zerhouni EA. Precision of myocardial contour estimation from tagged MR images with a "black-blood" technique. Acad Radiol 1998;5:93-100.
    • (1998) Acad Radiol , vol.5 , pp. 93-100
    • Croisille, P.1    Guttman, M.A.2    Atalar, E.3    McVeigh, E.R.4    Zerhouni, E.A.5
  • 27
    • 0027070940 scopus 로고
    • Cardiac tagging with breath-hold cine MRI
    • McVeigh ER, Atalar E. Cardiac tagging with breath-hold cine MRI. Magn Reson Med 1992;28:318-327.
    • (1992) Magn Reson Med , vol.28 , pp. 318-327
    • McVeigh, E.R.1    Atalar, E.2
  • 29
    • 7344252972 scopus 로고    scopus 로고
    • Standard vs. centric segmented k-space phase encoding: SNR comparison in breath-hold SPGR cardiac imaging
    • Vancouver, B.C., Canada
    • Boxerman JL, Reeder SB, Zerhouni EA. Standard vs. centric segmented k-space phase encoding: SNR comparison in breath-hold SPGR cardiac imaging. In: Proceedings of the ISMRM, Fifth Annual Meeting, Vancouver, B.C., Canada, 1997. p. 138.
    • (1997) Proceedings of the ISMRM, Fifth Annual Meeting , pp. 138
    • Boxerman, J.L.1    Reeder, S.B.2    Zerhouni, E.A.3
  • 32
    • 0028145655 scopus 로고
    • Phase errors in multi-shot echo planar imaging
    • Feinberg DA, Oshio K. Phase errors in multi-shot echo planar imaging. Magn Reson Med 1994;32:535-539.
    • (1994) Magn Reson Med , vol.32 , pp. 535-539
    • Feinberg, D.A.1    Oshio, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.