메뉴 건너뛰기




Volumn 5, Issue 4, 2000, Pages 246-262

Patient set-up using portal images: 2D/2D image registration using mutual information

Author keywords

2D 2D registration; Mutual information; Portal images; Radiotherapy

Indexed keywords

ACCURACY; ALGORITHM; ARTICLE; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER SIMULATION; DOSIMETRY; ELECTRONICS; HUMAN; IMAGE PROCESSING; PATIENT POSITIONING; PHANTOM; PRIORITY JOURNAL; RADIATION FIELD;

EID: 0033743894     PISSN: 10929088     EISSN: None     Source Type: Journal    
DOI: 10.1002/1097-0150(2000)5     Document Type: Article
Times cited : (36)

References (27)
  • 1
    • 84947749072 scopus 로고    scopus 로고
    • A novel approach for the registration of 2D portal and 3D CT images for treatment setup verification in radiotherapy
    • Wells WM, Colchester A, Delp S, editors: Medical Image Computing and Computer-Assisted Intervention (MICCAI'98), First International Conference, Cambridge, MA, October 1998. Lecture Notes in Computer Science, Vol. 1496. Berlin, Heidelberg, New York: Springer
    • (1998) , pp. 1075-1086
    • Bansal, R.1    Staib, L.H.2    Chen, Z.3    Rangarajan, A.4    Knisely, J.5    Nath, R.6    Duncan, J.S.7
  • 2
    • 84957105657 scopus 로고    scopus 로고
    • Entropy-based, multiple-portal-to-3DCT registration for prostate radiotherapy using interactively estimated segmentation
    • Taylor C, Colchester A, editors: Medical Image Computing and Computer-Assisted Intervention (MICCAI'99), Second International Conference, Cambridge, England, September 1999. Lecture Notes in Computer Science, Vol. 1679. Berlin, Heidelberg, New York: Springer
    • (1999) , pp. 567-578
    • Bansal, R.1    Staib, L.H.2    Chen, Z.3    Rangarajan, A.4    Knisely, J.5    Nath, R.6    Duncan, J.S.7
  • 4
    • 22444455590 scopus 로고    scopus 로고
    • Motion measurements on low-contrast x-ray imagery
    • Wells WM, Colchester A, Delp S, editors: Medical Image Computing and Computer-Assisted Intervention (MICCAI'98), First International Conference, Cambridge, MA, October 1998. Lecture Notes in Computer Science, Vol. 1496. Berlin, Heidelberg, New York: Springer
    • (1998) , pp. 832-841
    • Berger, M.1    Gerig, G.2
  • 6
    • 84945574619 scopus 로고    scopus 로고
    • Experimental protocol for accuracy evaluation of 6-D localizers for Computer Integrated Surgery: Application to four optical localizers
    • Wells WM, Colchester A, Delp S, editors: Medical Image Computing and Computer-Assisted Intervention (MICCAI'98), First International Conference, Cambridge, MA, October 1998. Lecture Notes in Computer Science, Vol. 1496. Berlin, Heidelberg, New York: Springer
    • (1998) , pp. 277-284
    • Chassat, F.1    Lavallee, S.2
  • 7
    • 0003780309 scopus 로고
    • Automated verification of radiation treatment geometry
    • Ph.D. thesis. The Netherlands Cancer Institute, Amsterdam
    • (1995)
    • Gilhuijs, K.G.A.1
  • 15
    • 0002375331 scopus 로고
    • Registration for computer-integrated surgery: Methodology, state of the art
    • Taylor RH, Lavallee S, Burdea C, Mosges R, editors: Computer-Integrated Surgery. Cambridge, MA: MIT Press
    • (1995) , pp. 77-97
    • Lavallee, S.1
  • 25
    • 0002429737 scopus 로고
    • Introducing computer vision sensors in radiotherapy for accurate dose delivery
    • Second Annual Symposium on Medical Robotics and Computer Assisted Surgery (MRCAS'95), Baltimore, November 1995. New York: Wiley-Liss Inc.
    • (1995) , pp. 16-23
    • Vassal, P.1    Troccaz, J.2    Laieb, N.3    Cinquin, P.4    Bolla, M.5    Berraud, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.