메뉴 건너뛰기




Volumn 34, Issue 4, 1996, Pages 873-885

Interactive three dimensional inspection of patient setup in radiation therapy using digital portal images and computed tomography data

Author keywords

3D patient setup; Digitally reconstructed radiograph; Out of plane rotations; Portal imaging

Indexed keywords

ARTICLE; BEAM THERAPY; CANCER RADIOTHERAPY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER SIMULATION; DIAGNOSTIC ACCURACY; HUMAN; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; PRIORITY JOURNAL; QUANTITATIVE DIAGNOSIS; THREE DIMENSIONAL IMAGING;

EID: 0029996059     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/0360-3016(95)02183-3     Document Type: Article
Times cited : (54)

References (36)
  • 1
    • 0343610870 scopus 로고
    • Estimation of extraplanar rotations for determining patient misalignment in radiation therapy
    • Balter, J.; Pelizzari, C. A.; Chen, G. T. Y. Estimation of extraplanar rotations for determining patient misalignment in radiation therapy (Abstr.). Med. Phys. 18:610; 1991.
    • (1991) Med. Phys. , vol.18 , pp. 610
    • Balter, J.1    Pelizzari, C.A.2    Chen, G.T.Y.3
  • 2
    • 0026652740 scopus 로고
    • Correlation of projection radiographs in radiation therapy using open curve segments and points
    • Balter, J.; Pelizzari, C. A.; Chen, G. T. Y. Correlation of projection radiographs in radiation therapy using open curve segments and points. Med. Phys. 19:329-334; 1992.
    • (1992) Med. Phys. , vol.19 , pp. 329-334
    • Balter, J.1    Pelizzari, C.A.2    Chen, G.T.Y.3
  • 3
    • 0028246946 scopus 로고
    • Transfer errors of planning CT to simulator: A possible source of setup inaccuracies?
    • Bel, A.; Bartelink, H.; Vijlbrief, R. E.; Lebesque, J. V. Transfer errors of planning CT to simulator: A possible source of setup inaccuracies? Radiother. Oncol. 31:176-180; 1994.
    • (1994) Radiother. Oncol. , vol.31 , pp. 176-180
    • Bel, A.1    Bartelink, H.2    Vijlbrief, R.E.3    Lebesque, J.V.4
  • 4
    • 0028785762 scopus 로고
    • Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device
    • Bel, A.; Keus, R.; Vijlbrief, R. E.; Lebesque, J. V. Setup deviations in wedged pair irradiation of parotid gland and tonsillar tumors, measured with an electronic portal imaging device. Radiother. Oncol. 37:153-159; 1995.
    • (1995) Radiother. Oncol. , vol.37 , pp. 153-159
    • Bel, A.1    Keus, R.2    Vijlbrief, R.E.3    Lebesque, J.V.4
  • 5
    • 0027138281 scopus 로고
    • A verification procedure to improve patient set-up accuracy using portal images
    • Bel, A.; van Herk, M.; Bartelink, H.; Lebesque, J. V. A verification procedure to improve patient set-up accuracy using portal images. Radiother. Oncol. 29:253-260; 1993.
    • (1993) Radiother. Oncol. , vol.29 , pp. 253-260
    • Bel, A.1    Van Herk, M.2    Bartelink, H.3    Lebesque, J.V.4
  • 7
    • 0027172788 scopus 로고
    • Three dimensional verification of patient placement during radiotherapy using portal images
    • Bijhold, J. Three dimensional verification of patient placement during radiotherapy using portal images. Med. Phys. 20:347-356; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 347-356
    • Bijhold, J.1
  • 8
    • 0025932046 scopus 로고
    • Fast evaluation of patient setup during radiotherapy by aligning features in portal and simulator images
    • Bijhold, J.; van Herk, M.; Vijlbrief, R.; Lebesque, J. V. Fast evaluation of patient setup during radiotherapy by aligning features in portal and simulator images. Phys. Med. Biol. 12:1665-1679; 1991.
    • (1991) Phys. Med. Biol. , vol.12 , pp. 1665-1679
    • Bijhold, J.1    Van Herk, M.2    Vijlbrief, R.3    Lebesque, J.V.4
  • 9
    • 0027219182 scopus 로고
    • A technique for treatment verification in radiotherapy and its clinical applications
    • Ding, X. G.; Shalev, S.; Gluhchev, G. A technique for treatment verification in radiotherapy and its clinical applications. Med. Phys. 20:1135-1143; 1993
    • (1993) Med. Phys. , vol.20 , pp. 1135-1143
    • Ding, X.G.1    Shalev, S.2    Gluhchev, G.3
  • 10
    • 0011058923 scopus 로고
    • An image correlation procedure for Digitally Reconstructed Radiographs and Electronic Portal Images
    • Dong, L.; Boyer, A. L. An image correlation procedure for Digitally Reconstructed Radiographs and Electronic Portal Images (Abstr.). Med. Phys. 21:935; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 935
    • Dong, L.1    Boyer, A.L.2
  • 11
    • 0343175338 scopus 로고
    • A ray tracing program based on Bresenham algorithm for generating Digitally Reconstructed Radiographs
    • Dong, L.; Kachilla, D.; Boyer, A. L. A ray tracing program based on Bresenham algorithm for generating Digitally Reconstructed Radiographs (abstr.). Med. Phys. 21:886; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 886
    • Dong, L.1    Kachilla, D.2    Boyer, A.L.3
  • 12
    • 0027183908 scopus 로고
    • Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials
    • Gall, K. P.; Verhey, L. J. Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials. Med. Phys. 20:1153-1159; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 1153-1159
    • Gall, K.P.1    Verhey, L.J.2
  • 15
    • 0027278542 scopus 로고
    • Automatic on-line inspection of patient setup in radiation therapy using digital portal images
    • Gilhuijs, K. G. A.; van Herk, M. Automatic on-line inspection of patient setup in radiation therapy using digital portal images. Med. Phys. 20:667-677; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 667-677
    • Gilhuijs, K.G.A.1    Van Herk, M.2
  • 16
    • 0020582071 scopus 로고
    • Multi-dimensional treatment planning: II. Beams's eye-view, back projection, and projection through CT sections
    • Goitein, M.; Abrams, M.; Rowell, D.; Pollari, H.; Wiles, J. Multi-dimensional treatment planning: II. Beams's eye-view, back projection, and projection through CT sections. Int. J. Radiat. Oncol. Biol. Phys. 9:789-797; 1983.
    • (1983) Int. J. Radiat. Oncol. Biol. Phys. , vol.9 , pp. 789-797
    • Goitein, M.1    Abrams, M.2    Rowell, D.3    Pollari, H.4    Wiles, J.5
  • 21
    • 0021063113 scopus 로고
    • Patterns of care study: Hodgkin's disease relapse rates and adequacy of portals
    • Kinzie, J. J.; Hanks, G. E.; Maclean, C. J.; Kramer, S. Patterns of care study: Hodgkin's disease relapse rates and adequacy of portals. Cancer 52:2223-2226; 1983.
    • (1983) Cancer , vol.52 , pp. 2223-2226
    • Kinzie, J.J.1    Hanks, G.E.2    Maclean, C.J.3    Kramer, S.4
  • 22
    • 0027237480 scopus 로고
    • Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers
    • Lam, K. L. L.; Ten Haken, R. K.; McShan, D. L.; Thornton, A. F., Jr. Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers. Med. Phys. 20:1145-1152; 1993.
    • (1993) Med. Phys. , vol.20 , pp. 1145-1152
    • Lam, K.L.L.1    Ten Haken, R.K.2    McShan, D.L.3    Thornton A.F., Jr.4
  • 23
    • 0026050773 scopus 로고
    • The simultaneous boost technique; the concept of relative normalized total dose
    • Lebesque, J. V.; Keus, R. The simultaneous boost technique; the concept of relative normalized total dose. Radiother. Oncol. 22:45-55; 1991.
    • (1991) Radiother. Oncol. , vol.22 , pp. 45-55
    • Lebesque, J.V.1    Keus, R.2
  • 24
    • 0027996228 scopus 로고
    • A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs
    • Lemieux, L.; Jagoe, R.; Fish, D. R.; Kitchen, N. D.; Thomas, D. G. T. A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs. Med. Phys. 21:1749-1760; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1749-1760
    • Lemieux, L.1    Jagoe, R.2    Fish, D.R.3    Kitchen, N.D.4    Thomas, D.G.T.5
  • 25
    • 0016207636 scopus 로고
    • Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields
    • Marks, J. E.; Haus, A. G.; Sutton, H. G.; Griem, M. L. Localization error in the radiotherapy of Hodgkin's disease and malignant lymphoma with extended mantle fields. Cancer 34:83-90; 1974.
    • (1974) Cancer , vol.34 , pp. 83-90
    • Marks, J.E.1    Haus, A.G.2    Sutton, H.G.3    Griem, M.L.4
  • 26
    • 0342305812 scopus 로고
    • A comparison of line integral algorithms
    • Mitchell, J. R.; Dickof, P.; Law, A. G. A comparison of line integral algorithms. Comput. Phys. 2:166-172; 1990.
    • (1990) Comput. Phys. , vol.2 , pp. 166-172
    • Mitchell, J.R.1    Dickof, P.2    Law, A.G.3
  • 27
    • 0028260271 scopus 로고
    • A semi-automatic method for registration of portal images
    • Mosely, J.; Munro, P. A semi-automatic method for registration of portal images. Med. Phys. 21:551-558; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 551-558
    • Mosely, J.1    Munro, P.2
  • 28
    • 0025273449 scopus 로고
    • Computation of digitally reconstructed radiographs for use in radiotherapy treatment design
    • Sherouse, G. W.; Novins, K.; Chaney, E. L. Computation of digitally reconstructed radiographs for use in radiotherapy treatment design. Int. J. Radiat. Oncol. Biol. Phys. 18:651-658; 1990.
    • (1990) Int. J. Radiat. Oncol. Biol. Phys. , vol.18 , pp. 651-658
    • Sherouse, G.W.1    Novins, K.2    Chaney, E.L.3
  • 29
    • 0019856668 scopus 로고
    • Solution to treatment planning problems using coordinate transformations
    • Siddon, R. L. Solution to treatment planning problems using coordinate transformations. Med. Phys. 8:766-774; 1981.
    • (1981) Med. Phys. , vol.8 , pp. 766-774
    • Siddon, R.L.1
  • 30
    • 0021968598 scopus 로고
    • Calculation of radiological depth
    • Siddon, R. L. Calculation of radiological depth. Med. Phys. 12:84-87; 1985.
    • (1985) Med. Phys. , vol.12 , pp. 84-87
    • Siddon, R.L.1
  • 31
    • 0025727878 scopus 로고
    • Three dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging
    • Thornton, A. F., Jr.; Ten Haken, R. K.; Gerhardsson, A.; Correll, M. Three dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imaging. Radiother. Oncol. 20:224-228; 1991.
    • (1991) Radiother. Oncol. , vol.20 , pp. 224-228
    • Thornton A.F., Jr.1    Ten Haken, R.K.2    Gerhardsson, A.3    Correll, M.4
  • 33
    • 0028803534 scopus 로고
    • Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration
    • van Herk, M.; Bruce, A.; Kroes, A. P. G.; Shouman, T.; Touw, A.; Lebesque, J. V. Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration. Int. J. Radiat. Oncol. Biol. Phys. 33:1311-1320; 1995.
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.33 , pp. 1311-1320
    • Van Herk, M.1    Bruce, A.2    Kroes, A.P.G.3    Shouman, T.4    Touw, A.5    Lebesque, J.V.6
  • 34
    • 0027933729 scopus 로고
    • Automatic three dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching
    • van Herk, M.; Kooy, H. Automatic three dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching. Med. Phys. 21:1163-1178; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1163-1178
    • Van Herk, M.1    Kooy, H.2
  • 35
    • 0023885087 scopus 로고
    • A matrix ionization chamber imaging device for on-line patient set-up verification during radiotherapy
    • van Herk, M.; Meertens, H. A matrix ionization chamber imaging device for on-line patient set-up verification during radiotherapy. Radiother. Oncol. 11:369-378; 1988.
    • (1988) Radiother. Oncol. , vol.11 , pp. 369-378
    • Van Herk, M.1    Meertens, H.2
  • 36
    • 0029864905 scopus 로고    scopus 로고
    • Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data
    • Gilhuijs, K. G. A.; van de Ven, P. J. H.; van Herk, M. Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data (in press). Med. Phys. 1996.
    • (1996) Med. Phys.
    • Gilhuijs, K.G.A.1    Van De Ven, P.J.H.2    Van Herk, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.