메뉴 건너뛰기




Volumn 2, Issue , 2000, Pages 768-771

A robust knowledge-based technique for ischemia detection in noisy ECGs

Author keywords

[No Author keywords available]

Indexed keywords

KNOWLEDGE BASED SYSTEMS; SIGNAL PROCESSING; SIGNAL TO NOISE RATIO; CARDIOLOGY; DEMODULATION; ELECTROMYOGRAPHY; SIGNAL DISTORTION; SIGNAL INTERFERENCE;

EID: 0033659020     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/KES.2000.884159     Document Type: Conference Paper
Times cited : (12)

References (10)
  • 1
    • 0242405675 scopus 로고
    • Continuous monitoring and detection of ST-T changes in ischemic patients
    • R. Silipo, A. Taddei, and C. Marchesi, "Continuous Monitoring and Detection of ST-T Changes in Ischemic Patients", IEEE Comput. Cardiol., pp. 225-228, 1994.
    • (1994) IEEE Comput. Cardiol. , pp. 225-228
    • Silipo, R.1    Taddei, A.2    Marchesi, C.3
  • 3
    • 0030292888 scopus 로고    scopus 로고
    • Accuracy of 50 Hz interference subtraction from an electrocardiogram
    • Nov
    • I. A. Dotsinsky and I. K. Daskalov, "Accuracy of 50 Hz Interference Subtraction from an Electrocardiogram", Med. Biol. Eng. Comp., vol. 34, pp. 489-494, Nov. 1996.
    • (1996) Med. Biol. Eng. Comp. , vol.34 , pp. 489-494
    • Dotsinsky, I.A.1    Daskalov, I.K.2
  • 4
    • 0027104086 scopus 로고
    • Filters for the reduction of baseline wander and muscle artifact in the ECG
    • V. De Pinto, "Filters for the Reduction of Baseline Wander and Muscle Artifact in the ECG", Journal of Electrocardiology, vol. 25, suppl., pp. 40-48, 1992.
    • (1992) Journal of Electrocardiology , vol.25 , pp. 40-48
    • de Pinto, V.1
  • 5
    • 0030152772 scopus 로고    scopus 로고
    • Comparing stress ECG enhancement algorithms (With an introduction to a filter bank based approach)
    • May/June
    • V. X. Afonso, W. J. Tompkins, T. Q. Nguyen, K. Michler, and S. Luo, "Comparing Stress ECG Enhancement Algorithms (With an introduction to a filter bank based approach)", IEEE Eng. Med. Biol., pp. 37-44, May/June 1996.
    • (1996) IEEE Eng. Med. Biol. , pp. 37-44
    • Afonso, V.X.1    Tompkins, W.J.2    Nguyen, T.Q.3    Michler, K.4    Luo, S.5
  • 6
    • 0020001518 scopus 로고
    • Digital FIR filtering for removal of ECG baseline wander
    • Jul./Sep
    • J. P. Marques De Sa, "Digital FIR Filtering for Removal of ECG Baseline Wander", Journal of Clinical Engineering, vol. 7, no. 3, pp. 235-240 Jul./Sep. 1982.
    • (1982) Journal of Clinical Engineering , vol.7 , Issue.3 , pp. 235-240
    • de Sa, J.P.M.1
  • 7
    • 0022270421 scopus 로고
    • Removal of base-line wander and power-line interference from the ECG by an efficient FIR filter with a reduced number of taps
    • and Dec
    • J. A. Van Alste' and T. S. Schilder, "Removal of Base-Line Wander and Power-Line Interference from the ECG by an Efficient FIR Filter with a Reduced Number of Taps", IEEE Trans. Biomed. Eng., vol. BME-32, no. 12, pp. 1052-1060, Dec. 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , Issue.12 , pp. 1052-1060
    • van Alste, J.A.1    Schilder, T.S.2
  • 10
    • 0032031794 scopus 로고    scopus 로고
    • Developments in ECG acquisition, preprocessing, parameter measurement, and recording
    • Mar./Apr
    • I. K. Daskalov, I. A. Dotsinsky, and I. I. Christov, "Developments in ECG Acquisition, Preprocessing, Parameter Measurement, and Recording", IEEE Eng. Med. Biol., vol. 17, no. 2, pp. 50-58, Mar./Apr. 1998.
    • (1998) IEEE Eng. Med. Biol. , vol.17 , Issue.2 , pp. 50-58
    • Daskalov, I.K.1    Dotsinsky, I.A.2    Christov, I.I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.