Volumn 17, Issue 2, 1998, Pages 50-58

Developments of ECG acquisition, preprocessing, parameter measurement and recording

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; COMPUTER ARCHITECTURE; DATA ACQUISITION; DIGITAL SIGNAL PROCESSING; INTERFERENCE SUPPRESSION; REAL TIME SYSTEMS; RECORDING; SIGNAL DETECTION; THERMAL PRINTING; WAVEFORM ANALYSIS;

EID: 0032031794     PISSN: 07395175     EISSN: None     Source Type: Journal    
DOI: 10.1109/51.664031     Document Type: Article
Times cited : (149)

References (33)
  • 2
    • 0344206887 scopus 로고
    • A family of microcomputer electrocardiographs
    • Carson ER, Kneppo P, Krekule I (Eds), Plenum Press, New York and London
    • Daskalov IK: A family of microcomputer electrocardiographs. In: Carson ER, Kneppo P, Krekule I (Eds): Advances in Biomedical Measurement, Plenum Press, New York and London: 3-20, 1988.
    • (1988) Advances in Biomedical Measurement , pp. 3-20
    • Daskalov, I.K.1
  • 3
    • 0020111867 scopus 로고
    • Amplification of biosignals by body potential driving
    • Levkov CL: Amplification of biosignals by body potential driving. Med. & Biol. Eng. & Comput. 20: 248-250, 1982.
    • (1982) Med. & Biol. Eng. & Comput. , vol.20 , pp. 248-250
    • Levkov, C.L.1
  • 6
    • 0013920022 scopus 로고
    • The low frequency response of electrocardiographs, a frequent source of recording errors
    • Berson AS, Pipberger HV: The low frequency response of electrocardiographs, a frequent source of recording errors. Am. Heart J. 71: 779-89, 1966.
    • (1966) Am. Heart J. , vol.71 , pp. 779-789
    • Berson, A.S.1    Pipberger, H.V.2
  • 7
    • 0021837982 scopus 로고
    • Artefactual ST abnormalities due to electrocardiographic design
    • Taylor DI, Vincent R: Artefactual ST abnormalities due to electrocardiographic design. Br. Heart J. 54: 121-128, 1985.
    • (1985) Br. Heart J. , vol.54 , pp. 121-128
    • Taylor, D.I.1    Vincent, R.2
  • 8
    • 0017580006 scopus 로고
    • ECG baseline stabilization for screening analysis
    • Kargel, Basel
    • Daskalov IK: ECG baseline stabilization for screening analysis. Adv. Cardiol., (Kargel, Basel) 19: 144-146, 1977.
    • (1977) Adv. Cardiol. , vol.19 , pp. 144-146
    • Daskalov, I.K.1
  • 11
    • 0003704668 scopus 로고
    • Williams & Willkins (Eds). 9-th Edition, London, Munich, Sydney, Tokyo
    • Wagner GS: Marriott's practical electrocardiography. In: Williams & Willkins (Eds). 9-th Edition, London, Munich, Sydney, Tokyo, 1994.
    • (1994) Marriott's Practical Electrocardiography
    • Wagner, G.S.1
  • 14
    • 2642680494 scopus 로고    scopus 로고
    • note
    • IEC 62D(CO)6A: Draft amendment 2 to IEC 601-1; Medical electrical equipment part 1; General requirements for safety.
  • 15
    • 0015588559 scopus 로고
    • 60 Hz in electrocardiography
    • Huhta JC, Webster JG: 60 Hz in electrocardiography. IEEE Trans. BME 20, No 2: 91-101, 1973.
    • (1973) IEEE Trans. BME , vol.20 , Issue.2 , pp. 91-101
    • Huhta, J.C.1    Webster, J.G.2
  • 16
    • 0019806015 scopus 로고
    • Comments on "Ground free ECG recording with two electrodes."
    • Towe BC: Comments on "Ground free ECG recording with two electrodes." IEEE Trans. BME 28, No 12: 838-839, 1981.
    • (1981) IEEE Trans. BME , vol.28 , Issue.12 , pp. 838-839
    • Towe, B.C.1
  • 17
    • 0020332050 scopus 로고
    • Fetal electrocardiogram enhancement by time-sequenced adaptive filtering
    • Ferrara ER, Widrow B: Fetal electrocardiogram enhancement by time-sequenced adaptive filtering. IEEE Trans. BME 29: 458-460, 1982.
    • (1982) IEEE Trans. BME , vol.29 , pp. 458-460
    • Ferrara, E.R.1    Widrow, B.2
  • 18
    • 0020971608 scopus 로고
    • A learning filter for removing noise interference
    • Furno GS, Tompkins WJ: A learning filter for removing noise interference. IEEE Trans. BME 30: 234-235, 1983.
    • (1983) IEEE Trans. BME , vol.30 , pp. 234-235
    • Furno, G.S.1    Tompkins, W.J.2
  • 19
    • 0022269734 scopus 로고
    • Digital filters for real-time ECG signal processing using microprocessors
    • Ahlstrom ML, Tompkins WJ: Digital filters for real-time ECG signal processing using microprocessors. IEEE Trans. BME 32: 708-713, 1985.
    • (1985) IEEE Trans. BME , vol.32 , pp. 708-713
    • Ahlstrom, M.L.1    Tompkins, W.J.2
  • 20
    • 0030032972 scopus 로고    scopus 로고
    • A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG
    • Hamilton PS: A comparison of adaptive and nonadaptive filters for reduction of power line interference in the ECG. IEEE Trans. BME 43: 105-109, 1996.
    • (1996) IEEE Trans. BME , vol.43 , pp. 105-109
    • Hamilton, P.S.1
  • 21
    • 0026203883 scopus 로고
    • Application of adaptive filtering to ECG analysis: Noise Cancellation and Arrhythmia detection
    • Thakor NV, Zhu YS: Application of adaptive filtering to ECG analysis: Noise Cancellation and Arrhythmia detection. Med. & Biol. Eng. & Comput. 38: 785-794, 1991.
    • (1991) Med. & Biol. Eng. & Comput. , vol.38 , pp. 785-794
    • Thakor, N.V.1    Zhu, Y.S.2
  • 23
    • 0024041872 scopus 로고
    • New approach to the digital elimination of 50 Hz interference from the electrocardiogram
    • Christov II, Dotsinsky IA: New approach to the digital elimination of 50 Hz interference from the electrocardiogram. Med. & Biol. Eng. & Comput. 26: 431-434, 1988.
    • (1988) Med. & Biol. Eng. & Comput. , vol.26 , pp. 431-434
    • Christov, I.I.1    Dotsinsky, I.A.2
  • 24
    • 0030292888 scopus 로고    scopus 로고
    • Accuracy of 50 Hz interference subtraction from an electrocardiogram
    • Dotsinsky IA, Daskalov IK: Accuracy of 50 Hz interference subtraction from an electrocardiogram. Med. & Biol. Eng. & Comput. 34: 489-493, 1996.
    • (1996) Med. & Biol. Eng. & Comput. , vol.34 , pp. 489-493
    • Dotsinsky, I.A.1    Daskalov, I.K.2
  • 26
    • 0021461851 scopus 로고
    • Software QRS detection in ambulatory monitoring - A review
    • Pahlm O, Sörnmo L: Software QRS detection in ambulatory monitoring - a review. Med. & Biol. Eng. & Comput. 22: 289-297, 1984.
    • (1984) Med. & Biol. Eng. & Comput. , vol.22 , pp. 289-297
    • Pahlm, O.1    Sörnmo, L.2
  • 28
    • 0000726344 scopus 로고
    • Software real time QRS detection
    • Dotsinsky I: Software real time QRS detection. Med. & Biol. Eng. & Comput. 29, Supplement: 337, 1991
    • (1991) Med. & Biol. Eng. & Comput. , vol.29 , Issue.SUPPL. , pp. 337
    • Dotsinsky, I.1
  • 29
    • 0026746066 scopus 로고
    • Ventricular beat classifier using fractal number clustering
    • Bakardjian H: Ventricular beat classifier using fractal number clustering. Med. & Biol. Eng. & Comput. 30: 495-502, 1992.
    • (1992) Med. & Biol. Eng. & Comput. , vol.30 , pp. 495-502
    • Bakardjian, H.1
  • 30
    • 0031171725 scopus 로고    scopus 로고
    • Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation
    • Daskalov IK, Christov II: Improvement of resolution in measurement of electrocardiogram RR intervals by interpolation. Med. Eng. & Phys. 19: 375-379, 1997.
    • (1997) Med. Eng. & Phys. , vol.19 , pp. 375-379
    • Daskalov, I.K.1    Christov, I.I.2
  • 32
    • 0023305901 scopus 로고
    • Orthogonal electrocardiogram derived from the limb and chest electrodes of the conventional 12-lead system
    • Levkov CL: Orthogonal electrocardiogram derived from the limb and chest electrodes of the conventional 12-lead system. Med. & Biol. Eng. & Comp. 25: 155-164, 1987.
    • (1987) Med. & Biol. Eng. & Comp. , vol.25 , pp. 155-164
    • Levkov, C.L.1
  • 33
    • 0025667599 scopus 로고
    • Recording vectorcardiographic loops with a microdot thermal printer
    • Christov II, Dotsinsky IA: Recording vectorcardiographic loops with a microdot thermal printer. Frontiers Med. Biol. Eng. 2, No 1: 37-42, 1988.
    • (1988) Frontiers Med. Biol. Eng. , vol.2 , Issue.1 , pp. 37-42
    • Christov, I.I.1    Dotsinsky, I.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.