메뉴 건너뛰기




Volumn 34, Issue 6, 1996, Pages 489-494

Accuracy of 50 Hz interference subtraction from an electrocardiogram

Author keywords

50 hz interference; Electrocardiogram; Filtering; Power line noise; Subtraction method

Indexed keywords

ADAPTIVE FILTERING; COMPUTER GRAPHICS; DATABASE SYSTEMS; ELECTRIC IMPEDANCE; FUNCTION GENERATORS; INTERFERENCE SUPPRESSION; MATHEMATICAL MODELS; MODAL ANALYSIS; NATURAL FREQUENCIES; SPECTRUM ANALYSIS; SPURIOUS SIGNAL NOISE;

EID: 0030292888     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02523857     Document Type: Article
Times cited : (26)

References (11)
  • 1
    • 0022269734 scopus 로고
    • Digital filters for real-time ECG signal processing using microprocessors
    • AHLSTROM, M. L., and TOMPKINS, W. J. (1985): 'Digital filters for real-time ECG signal processing using microprocessors', IEEE Trans., BME-32, pp. 708-713
    • (1985) IEEE Trans. , vol.BME-32 , pp. 708-713
    • Ahlstrom, M.L.1    Tompkins, W.J.2
  • 2
    • 0024041872 scopus 로고
    • New approach to the digital elimination of 50 Hz interference from the electrocardiogram
    • CHRISTOV, I. I., and DOTSINSKY, I. A. (1988): 'New approach to the digital elimination of 50 Hz interference from the electrocardiogram', Med. Biol. Eng. Comput., 26, pp. 431-434
    • (1988) Med. Biol. Eng. Comput. , vol.26 , pp. 431-434
    • Christov, I.I.1    Dotsinsky, I.A.2
  • 3
    • 0023101679 scopus 로고
    • Estimation and removal of power-line interference in the electrocardiogram: A comparison of digital approaches
    • CRAMER, E., MCMANUS, C. D., and NEUBERT, D. (1987): 'Estimation and removal of power-line interference in the electrocardiogram: a comparison of digital approaches', Comput. Biomed. Res., 20, pp. 12-28
    • (1987) Comput. Biomed. Res. , vol.20 , pp. 12-28
    • Cramer, E.1    Mcmanus, C.D.2    Neubert, D.3
  • 4
    • 0029300831 scopus 로고
    • Dynamic Levkov-Christov subtraction of mains interference
    • DOTSINSKY, I. A., and DASKALOV, I. K. (1995): 'Dynamic Levkov-Christov subtraction of mains interference', Med. Biol. Eng. Comput., 33, p. 360
    • (1995) Med. Biol. Eng. Comput. , vol.33 , pp. 360
    • Dotsinsky, I.A.1    Daskalov, I.K.2
  • 5
    • 0020332050 scopus 로고
    • Fetal electrocardiogram enhancement by time-sequenced adaptive filtering
    • FERRARA, E. R., and WIDROW, B. (1982): 'Fetal electrocardiogram enhancement by time-sequenced adaptive filtering', IEEE Trans., BME-29, pp. 458-460
    • (1982) IEEE Trans. , vol.BME-29 , pp. 458-460
    • Ferrara, E.R.1    Widrow, B.2
  • 6
    • 0020971608 scopus 로고
    • A learning filter for removing noise interference
    • FURNO, G. S., and TOMPKINS, W. J. (1983): 'A learning filter for removing noise interference', IEEE Trans., BME-30, pp. 234-235
    • (1983) IEEE Trans. , vol.BME-30 , pp. 234-235
    • Furno, G.S.1    Tompkins, W.J.2
  • 7
    • 0015588559 scopus 로고
    • 60 Hz in electrocardiography
    • HUHTA, J. C., and WEBSTER, J. G. (1973): '60 Hz in electrocardiography', IEEE Trans., BME-20, (2), pp. 91-101
    • (1973) IEEE Trans. , vol.BME-20 , Issue.2 , pp. 91-101
    • Huhta, J.C.1    Webster, J.G.2
  • 8
    • 0021461852 scopus 로고
    • Subtraction of 50 Hz interference from the electrocardiogram
    • LEVKOV, C., MICHOV, G., IVANOV, R., and DASKALOV, I. K. (1984): 'Subtraction of 50 Hz interference from the electrocardiogram', Med. Biol. Eng. Comput., 22, pp. 371-373
    • (1984) Med. Biol. Eng. Comput. , vol.22 , pp. 371-373
    • Levkov, C.1    Michov, G.2    Ivanov, R.3    Daskalov, I.K.4
  • 9
    • 0026203883 scopus 로고
    • Application of adaptive filtering to ECG analysis: Noise cancellation and arrythmia detection
    • THAKOR, N. V., and ZHU, Y.-S. (1991): 'Application of adaptive filtering to ECG analysis: noise cancellation and arrythmia detection', med. Biol. Eng. Comput., 38, pp. 785-794
    • (1991) Med. Biol. Eng. Comput. , vol.38 , pp. 785-794
    • Thakor, N.V.1    Zhu, Y.-S.2
  • 10
    • 0019806015 scopus 로고
    • Comments on "Ground free ECG recording with two electrodes"
    • TOWE, B. C. (1981): 'Comments on "Ground free ECG recording with two electrodes", IEEE Trans., BME-28, (12), pp. 838-839
    • (1981) IEEE Trans. , vol.BME-28 , Issue.12 , pp. 838-839
    • Towe, B.C.1
  • 11
    • 0027691269 scopus 로고
    • Dynamic Levkov-Christov subtraction of mains interference
    • YAN, X. G. (1993): 'Dynamic Levkov-Christov subtraction of mains interference', Med. Biol. Eng. Comput., 31, pp. 635-638
    • (1993) Med. Biol. Eng. Comput. , vol.31 , pp. 635-638
    • Yan, X.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.