메뉴 건너뛰기




Volumn 40, Issue 12, 1999, Pages 2053-2065

Comparative evaluation of MR-based partial-volume correction schemes for PET

Author keywords

Aging; Atrophy; Emission tomography; MRI; Partial volume correction

Indexed keywords

ADULT; ARTICLE; BRAIN ATROPHY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; HUMAN; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; POSITRON EMISSION TOMOGRAPHY; PRIORITY JOURNAL;

EID: 0033394937     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (231)

References (34)
  • 1
    • 0018367149 scopus 로고
    • Quantitation in positron emission computed tomography. 1. Effect of object size
    • Hoffman EJ, Huang SC, Phelps ME. Quantitation in positron emission computed tomography. 1. Effect of object size. J Comput Assist Tomogr. 1979;3:299-308.
    • (1979) J Comput Assist Tomogr , vol.3 , pp. 299-308
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3
  • 2
    • 0021261066 scopus 로고
    • Analysis of emission tomographic scan data: Limitations imposed by resolution and background
    • Kessler RM, Ellis JR, Eden M. Analysis of emission tomographic scan data: limitations imposed by resolution and background. J Comput Assist Tomogr. 1984;8:514-522.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 514-522
    • Kessler, R.M.1    Ellis, J.R.2    Eden, M.3
  • 3
    • 0342313962 scopus 로고
    • Effect of resolution on recovery of gray matter activity in FDG PET
    • Meltzer C, Nichols T, Mintun M. Effect of resolution on recovery of gray matter activity in FDG PET [abstract]. J Nucl Med. 1995;36(suppl):114P.
    • (1995) J Nucl Med , vol.36 , Issue.SUPPL.
    • Meltzer, C.1    Nichols, T.2    Mintun, M.3
  • 5
    • 0003147399 scopus 로고
    • Correction for partial-volume effects in PET using MRI-based 3D simulations of individual human brain metabolism
    • Meyers R, Cunningham V, Bailey D, Jones T, eds. San Diego, CA: Academic Press
    • Roussel O, Ma Y, Leger G, Gjedde A, Evans AC. Correction for partial-volume effects in PET using MRI-based 3D simulations of individual human brain metabolism. In: Meyers R, Cunningham V, Bailey D, Jones T, eds. Quantification of Brain Function Using PET. San Diego, CA: Academic Press; 1993:113-125.
    • (1993) Quantification of Brain Function Using PET , pp. 113-125
    • Roussel, O.1    Ma, Y.2    Leger, G.3    Gjedde, A.4    Evans, A.C.5
  • 6
    • 0027638742 scopus 로고
    • 3D simulations of radiotracer uptake in deep nuclei of human brain
    • Roussel O, Ma Y, Kamber M, Evans AC. 3D simulations of radiotracer uptake in deep nuclei of human brain. Comput Med Imaging Graph. 1993;17:373-379.
    • (1993) Comput Med Imaging Graph , vol.17 , pp. 373-379
    • Roussel, O.1    Ma, Y.2    Kamber, M.3    Evans, A.C.4
  • 7
    • 0023735354 scopus 로고
    • Regional correction of positron emission tomography data for the effects of cerebral atrophy
    • Videen TO, Perlmutter JS, Mintun MA, Raichle ME. Regional correction of positron emission tomography data for the effects of cerebral atrophy. J Cereb Blood Flow Metab. 1988;8:662-670.
    • (1988) J Cereb Blood Flow Metab , vol.8 , pp. 662-670
    • Videen, T.O.1    Perlmutter, J.S.2    Mintun, M.A.3    Raichle, M.E.4
  • 8
    • 0030054873 scopus 로고    scopus 로고
    • Influence of heterogeneous background on "hot object" quantitation in brain emission computed tomography
    • Links J, Zubieta J, Meltzer C, Stumpf M, Frost J. Influence of heterogeneous background on "hot object" quantitation in brain emission computed tomography. J Comput Assist Tomogr. 1996;20:680-687.
    • (1996) J Comput Assist Tomogr , vol.20 , pp. 680-687
    • Links, J.1    Zubieta, J.2    Meltzer, C.3    Stumpf, M.4    Frost, J.5
  • 9
    • 0029788383 scopus 로고    scopus 로고
    • Regional hypometabolism in Alzheimer disease as measured by PET following correction for effects of partial-volume averaging
    • Meltzer C, Zubieta J, Brandt J, Tune L, Mayberg H, Frost J. Regional hypometabolism in Alzheimer disease as measured by PET following correction for effects of partial-volume averaging. Neurology. 1996;47:454-461.
    • (1996) Neurology , vol.47 , pp. 454-461
    • Meltzer, C.1    Zubieta, J.2    Brandt, J.3    Tune, L.4    Mayberg, H.5    Frost, J.6
  • 10
    • 0025957221 scopus 로고
    • Analysis of brain and cerebrospinal fluid volumes with MR imaging: Impact on PET data correction for atrophy. Part II. Aging and Alzheimer dementia
    • Tanna NK, Kohn MI, Horwich DN, et al. Analysis of brain and cerebrospinal fluid volumes with MR imaging: impact on PET data correction for atrophy. Part II. Aging and Alzheimer dementia. Radiology. 1991;178:123-130.
    • (1991) Radiology , vol.178 , pp. 123-130
    • Tanna, N.K.1    Kohn, M.I.2    Horwich, D.N.3
  • 11
    • 0027482523 scopus 로고
    • Quantitative analysis of PET and MRI data in normal aging and Alzheimer's disease: Atrophy weighted total brain metabolism and absolute whole brain metabolism as reliable discriminators
    • Alavi A, Newberg AB, Souder E, Berlin JA. Quantitative analysis of PET and MRI data in normal aging and Alzheimer's disease: atrophy weighted total brain metabolism and absolute whole brain metabolism as reliable discriminators. J Nucl Med. 1993;34:1681-1687.
    • (1993) J Nucl Med , vol.34 , pp. 1681-1687
    • Alavi, A.1    Newberg, A.B.2    Souder, E.3    Berlin, J.A.4
  • 13
    • 0028143172 scopus 로고
    • Quantitative comparisons of image registration techniques based on high-resolution of MRI of the brain
    • Strother S, Anderson J, Xu X-L, Liow J, Bonar D, Rottenberg D. Quantitative comparisons of image registration techniques based on high-resolution of MRI of the brain. J Comput Assist Tomogr. 1994;18:954-962.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 954-962
    • Strother, S.1    Anderson, J.2    Xu, X.-L.3    Liow, J.4    Bonar, D.5    Rottenberg, D.6
  • 14
    • 0025266234 scopus 로고
    • A method of anatomical localization fur positron emission tomography using magnetic resonance imaging
    • Meltzer CC, Bryan RN, Holcomb HH, et al. A method of anatomical localization fur positron emission tomography using magnetic resonance imaging. J Comput Assist Tomogr. 1990;14:418-426.
    • (1990) J Comput Assist Tomogr , vol.14 , pp. 418-426
    • Meltzer, C.C.1    Bryan, R.N.2    Holcomb, H.H.3
  • 15
    • 0026098101 scopus 로고
    • Alzheimer disease: Measuring loss of cerebral gray matter with MR imaging
    • Rusinek H, de Leon MJ, George AE, et al. Alzheimer disease: measuring loss of cerebral gray matter with MR imaging. Radiology 1991;178:109-114.
    • (1991) Radiology , vol.178 , pp. 109-114
    • Rusinek, H.1    De Leon, M.J.2    George, A.E.3
  • 17
    • 0026700928 scopus 로고
    • Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial-volume effects
    • Mueller-Gaertner HW, Links JM, Prince JL, et al. Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial-volume effects. J Cereb Blood Flow Metab. 1992;12: 571-583.
    • (1992) J Cereb Blood Flow Metab , vol.12 , pp. 571-583
    • Mueller-Gaertner, H.W.1    Links, J.M.2    Prince, J.L.3
  • 18
    • 0003415130 scopus 로고    scopus 로고
    • ROI-versus tissue-based partial-volume correction
    • Rousset O, Ma Y, Evans AC. ROI-versus tissue-based partial-volume correction [abstract]. Neuroimage. 1997;5:B13.
    • (1997) Neuroimage , vol.5
    • Rousset, O.1    Ma, Y.2    Evans, A.C.3
  • 19
    • 0342313960 scopus 로고    scopus 로고
    • Accuracy of the Mueller-Gaertner partial-volume correction in brain PET
    • Fancy F, Gage H, Harkness B. Accuracy of the Mueller-Gaertner partial-volume correction in brain PET (abstract). J Nucl Med. 1996;37(suppl):225P.
    • (1996) J Nucl Med , vol.37 , Issue.SUPPL.
    • Fancy, F.1    Gage, H.2    Harkness, B.3
  • 20
    • 0029967309 scopus 로고    scopus 로고
    • MR-based correction of brain PET measurements for heterogeneous gray matter radioactivity distribution
    • Meltzer C, Zubieta J, Links J, Brakeman P, Stumpf M, Frost JJ. MR-based correction of brain PET measurements for heterogeneous gray matter radioactivity distribution. J Cerebr Blood Flow Metab. 1996;16:650-658.
    • (1996) J Cerebr Blood Flow Metab , vol.16 , pp. 650-658
    • Meltzer, C.1    Zubieta, J.2    Links, J.3    Brakeman, P.4    Stumpf, M.5    Frost, J.J.6
  • 21
    • 0030353814 scopus 로고    scopus 로고
    • Investigation of partial-volume correction methods for brain FDG PET studies
    • Yang J, Huang S, Mega M, et al. Investigation of partial-volume correction methods for brain FDG PET studies. IEEE Trans Nucl Sci. 1996;43:3322-3327.
    • (1996) IEEE Trans Nucl Sci , vol.43 , pp. 3322-3327
    • Yang, J.1    Huang, S.2    Mega, M.3
  • 22
    • 0031150145 scopus 로고    scopus 로고
    • Characterization of dynamic 3-D PET imaging for functional brain mapping
    • Barnes D, Egan G, O'Keefe G, Abbott, D. Characterization of dynamic 3-D PET imaging for functional brain mapping. IEEE Trans Med Imaging. 1997;16:261-269.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 261-269
    • Barnes, D.1    Egan, G.2    O'Keefe, G.3    Abbott, D.4
  • 23
    • 0342748807 scopus 로고    scopus 로고
    • Louvian-la-Neuve, Belgium: Catholic University of Louvain. Available at: Accessed October 19
    • Michel, Christian. IV-align software package. Louvian-la-Neuve, Belgium: Catholic University of Louvain. Available at: http://WHW.topo.ucl.ac.be. Accessed October 19, 1999.
    • (1999) IV-align Software Package
    • Michel, C.1
  • 24
    • 0019357118 scopus 로고
    • Quantitation in positron emission tomography: 5. Physical-anatomical effects
    • Mazziotta JC, Phelps ME, Plummer D, Kuhl DE. Quantitation in positron emission tomography: 5. Physical-anatomical effects. J Comput Assist Tomogr. 1981;5:734-743.
    • (1981) J Comput Assist Tomogr , vol.5 , pp. 734-743
    • Mazziotta, J.C.1    Phelps, M.E.2    Plummer, D.3    Kuhl, D.E.4
  • 25
    • 0002851049 scopus 로고
    • Stereotaxic techniques comparing foci intensity and location of activation areas in the brain as obtained using positron emission tomography (PET)
    • Wiseman M, Nichols T, Woods R, Sweeney J, Mintun M. Stereotaxic techniques comparing foci intensity and location of activation areas in the brain as obtained using positron emission tomography (PET) [abstract]. J Nucl Med. 1995;36(suppl): 93P.
    • (1995) J Nucl Med , vol.36 , Issue.SUPPL.
    • Wiseman, M.1    Nichols, T.2    Woods, R.3    Sweeney, J.4    Mintun, M.5
  • 27
    • 0029067185 scopus 로고
    • Regional cerebral function determined by FDG-PET in healthy volunteers: Normal patterns and changes with age
    • Loessner A, Alavi A, Lewandrowski K-U, Mozley D, Souder E, Gur R. Regional cerebral function determined by FDG-PET in healthy volunteers: normal patterns and changes with age. J Nucl Med. 1995;36:1141-1149.
    • (1995) J Nucl Med , vol.36 , pp. 1141-1149
    • Loessner, A.1    Alavi, A.2    Lewandrowski, K.-U.3    Mozley, D.4    Souder, E.5    Gur, R.6
  • 28
    • 0026303718 scopus 로고
    • Decrease of frontal metabolism demonstrated by positron emission tomography in a population of healthy elderly volunteers
    • Salmon E, Maquet P, Sadzot B, Degueldre C, Lemaire C, Franck G. Decrease of frontal metabolism demonstrated by positron emission tomography in a population of healthy elderly volunteers. Acta Neurol Belg. 1991;91:288-295.
    • (1991) Acta Neurol Belg , vol.91 , pp. 288-295
    • Salmon, E.1    Maquet, P.2    Sadzot, B.3    Degueldre, C.4    Lemaire, C.5    Franck, G.6
  • 29
    • 0023712050 scopus 로고
    • Sensitivity of cerebral glucose metabolism to age, gender, brain volume, brain atrophy, and cerebrovascular risk factors
    • Yoshii F, Barker W, Chang J, et al. Sensitivity of cerebral glucose metabolism to age, gender, brain volume, brain atrophy, and cerebrovascular risk factors. J Cereb Bland Flow Metab. 1988;8:654-661.
    • (1988) J Cereb Bland Flow Metab , vol.8 , pp. 654-661
    • Yoshii, F.1    Barker, W.2    Chang, J.3
  • 30
    • 0026656848 scopus 로고
    • Regional cerebral oxygen consumption, blood flow, and blood volume in healthy human aging
    • Marchal G, Rouix P, Petit-Taboue M-C, et al. Regional cerebral oxygen consumption, blood flow, and blood volume in healthy human aging. Arch Neurol. 1992;49:1013-1020.
    • (1992) Arch Neurol , vol.49 , pp. 1013-1020
    • Marchal, G.1    Rouix, P.2    Petit-Taboue, M.-C.3
  • 32
    • 0031012026 scopus 로고    scopus 로고
    • Sulcal, ventricular, and while matter changes at MR imaging in the aging brain: Data from the Cardiovascular Health Study
    • Yue N, Arnold A, Longstreth W, et al. Sulcal, ventricular, and while matter changes at MR imaging in the aging brain: data from the Cardiovascular Health Study. Radiology. 1997;202:33-39.
    • (1997) Radiology , vol.202 , pp. 33-39
    • Yue, N.1    Arnold, A.2    Longstreth, W.3
  • 34
    • 0030967767 scopus 로고    scopus 로고
    • Changes in cerebral blood flow and oxygen metabolism related to magnetic resonance imaging white matter hyperintensities in Alzheimer's disease
    • Yamaji S, Ishii K, Sasaki M, et al. Changes in cerebral blood flow and oxygen metabolism related to magnetic resonance imaging white matter hyperintensities in Alzheimer's disease. J Nucl Med. 1997;38:1471-1474.
    • (1997) J Nucl Med , vol.38 , pp. 1471-1474
    • Yamaji, S.1    Ishii, K.2    Sasaki, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.