-
1
-
-
0001368728
-
Automatic recognition of electrocardiographic waves by digital computer
-
Stallmann F.W., Pipberger H.V. Automatic recognition of electrocardiographic waves by digital computer. Circ Res. 9:1961;1138-1143.
-
(1961)
Circ Res
, vol.9
, pp. 1138-1143
-
-
Stallmann, F.W.1
Pipberger, H.V.2
-
2
-
-
0022385397
-
Recommendations for measurement standards in quantitative electrocardiography
-
The CSE Working Party
-
The CSE Working Party. Recommendations for measurement standards in quantitative electrocardiography. Eur Heart J 1985;6:815-25.
-
(1985)
Eur Heart J
, vol.6
, pp. 815-825
-
-
-
3
-
-
0344206893
-
Technical recommendations
-
In: Macfarlane PW, Veitch-Lawrie TD, editors New York/Oxford/Beijing/Frankfurt/Sao Paulo/Sydney/Tokyo/Toronto: Pergamon Press, Appendix
-
Macfarlane PW, Veitch-Lawrie TD. Technical recommendations. In: Macfarlane PW, Veitch-Lawrie TD, editors. Comprehensive electrocardiology. New York/Oxford/Beijing/Frankfurt/Sao Paulo/Sydney/Tokyo/Toronto: Pergamon Press, 1989;Appendix 4:1583-656.
-
(1989)
Comprehensive Electrocardiology
, vol.4
, pp. 1583-1656
-
-
Macfarlane, P.W.1
Veitch-Lawrie, T.D.2
-
4
-
-
0028848048
-
Variation in the identification of Q wave initiation and its contribution to QT measurement
-
Murray A., McLaughlin N.B. Variation in the identification of Q wave initiation and its contribution to QT measurement. Physiol Meas. 16:1995;39-42.
-
(1995)
Physiol Meas
, vol.16
, pp. 39-42
-
-
Murray, A.1
McLaughlin, N.B.2
-
5
-
-
0028272466
-
Errors in manual measurement of QT intervals
-
Murray A., McLaughlin N.B., Bourke J.P., Doig J.C., Furniss S.S., Campbell R.W.F. Errors in manual measurement of QT intervals. Br Heart J. 71:1994;386-390.
-
(1994)
Br Heart J
, vol.71
, pp. 386-390
-
-
Murray, A.1
McLaughlin, N.B.2
Bourke, J.P.3
Doig, J.C.4
Furniss, S.S.5
Campbell, R.W.F.6
-
6
-
-
0029014582
-
Comparison of automatic QT measurement techniques in the normal 12 lead electrocardiogram
-
McLaughlin N.B., Campbell R.W.F., Murray A. Comparison of automatic QT measurement techniques in the normal 12 lead electrocardiogram. Br Heart J. 74:1995;84-89.
-
(1995)
Br Heart J
, vol.74
, pp. 84-89
-
-
McLaughlin, N.B.1
Campbell, R.W.F.2
Murray, A.3
-
7
-
-
0344206887
-
A family of microcomputer electrocardiographs
-
In: Carson E, Kneppo IP, Krekule I, editors New York/London: Plenum Press
-
Daskalov IK. A family of microcomputer electrocardiographs. In: Carson E, Kneppo IP, Krekule I, editors. Advances in biomedical measurement. New York/London: Plenum Press, 1988:3-20.
-
(1988)
Advances in Biomedical Measurement
, pp. 3-20
-
-
Daskalov, I.K.1
-
8
-
-
0344638415
-
Electrocardiogram acquisition, preprocessing and parameter measurement (invited lecture)
-
Abstracts 4th Eur Conf on Engineering and Medicine, Warsaw
-
Daskalov IK. Electrocardiogram acquisition, preprocessing and parameter measurement (invited lecture). Abstracts 4th Eur Conf on Engineering and Medicine, International Centre of Biocybernetics, Warsaw, 1997:7-8.
-
(1997)
International Centre of Biocybernetics
, pp. 7-8
-
-
Daskalov, I.K.1
-
9
-
-
0345069096
-
Detection of QRS complexes and ventricular ectopic beats in the electrocardiogram
-
Ilmenau, Technische Universitaet Ilmenau, Ilmenau, Germany
-
Dotsinsky I, Christov I. Detection of QRS complexes and ventricular ectopic beats in the electrocardiogram. Proc 42nd International Scientific Colloquium, Ilmenau, Technische Universitaet Ilmenau, Ilmenau, Germany, 1997:99-103.
-
(1997)
Proc 42nd International Scientific Colloquium
, pp. 99-103
-
-
Dotsinsky, I.1
Christov, I.2
-
10
-
-
0032031794
-
Developments in ECG acquisition, preprocessing, parameter measurement and recording
-
Daskalov I.K., Dotsinsky I.A., Christov I.I. Developments in ECG acquisition, preprocessing, parameter measurement and recording. IEEE Eng Med Biol. 17:1998;50-58.
-
(1998)
IEEE Eng Med Biol
, vol.17
, pp. 50-58
-
-
Daskalov, I.K.1
Dotsinsky, I.A.2
Christov, I.I.3
-
11
-
-
0022236669
-
Establishment of a reference library for evaluating computer ECG measurement programs
-
Willems J.I., Arnaud P., Van Bemmel J.H., Bourdillon P.J., Degani R., Denis B., Harms F.M.A., Macfarlane P.W., Mazzocca G., Meyer J., Rilsema van Eck H.J., Robles de Medina E.O., Zywietz C. Establishment of a reference library for evaluating computer ECG measurement programs. Comput Biomed Res. 18:1985;439-457.
-
(1985)
Comput Biomed Res
, vol.18
, pp. 439-457
-
-
Willems, J.I.1
Arnaud, P.2
Van Bemmel, J.H.3
Bourdillon, P.J.4
Degani, R.5
Denis, B.6
Harms, F.M.A.7
Macfarlane, P.W.8
Mazzocca, G.9
Meyer, J.10
Rilsema Van Eck, H.J.11
Robles De Medina, E.O.12
Zywietz, C.13
-
12
-
-
0021911322
-
Errors in visual determination of corrected QT (Qtc) interval during acute myocardial infarction
-
Ahnve S. Errors in visual determination of corrected QT (Qtc) interval during acute myocardial infarction. J Am Coll Cardiol. 5:1985;699-702.
-
(1985)
J Am Coll Cardiol
, vol.5
, pp. 699-702
-
-
Ahnve, S.1
-
13
-
-
0029958613
-
Interrater agreement in the measurement of QRS interval in tricyclic antidepressant overdose: Implications for monitoring and research
-
Buckley N.A., O'Connell D.L., Whyte I.M., Dawson A.H. Interrater agreement in the measurement of QRS interval in tricyclic antidepressant overdose: implications for monitoring and research. Ann Emerg Med. 28:1996;515-519.
-
(1996)
Ann Emerg Med
, vol.28
, pp. 515-519
-
-
Buckley, N.A.1
O'Connell, D.L.2
Whyte, I.M.3
Dawson, A.H.4
-
14
-
-
0021964239
-
Assessment of the performance of electrocardiographic computer programs with the use of a reference data base
-
Willems J.L., Arnaud P., Van Bemmel J.H., Bourdillon P.J., Brohet C., Dalla Volta S., Andersen J.D., Degani R., Denis B., Demester M., Dudeck J., Harms F.M.A., Macfarlane P.W., Mazzocca G., Meyer J., Michaelis J., Pardaens J., Poeppl S., Reardon B.C., Ritsema van Eck H.J., Robles de Medina E.O., Rubel P., Talmon J.L., Zywietz C. Assessment of the performance of electrocardiographic computer programs with the use of a reference data base. Circulation. 71:1985;523-534.
-
(1985)
Circulation
, vol.71
, pp. 523-534
-
-
Willems, J.L.1
Arnaud, P.2
Van Bemmel, J.H.3
Bourdillon, P.J.4
Brohet, C.5
Dalla Volta, S.6
Andersen, J.D.7
Degani, R.8
Denis, B.9
Demester, M.10
Dudeck, J.11
Harms, F.M.A.12
Macfarlane, P.W.13
Mazzocca, G.14
Meyer, J.15
Michaelis, J.16
Pardaens, J.17
Poeppl, S.18
Reardon, B.C.19
Ritsema Van Eck, H.J.20
Robles De Medina, E.O.21
Rubel, P.22
Talmon, J.L.23
Zywietz, C.24
more..
-
16
-
-
0020399995
-
QRS duration measurement using high-frequency electrocardiography: Applications and limitations of a new technique
-
Goldberger A.L., Bhargava V. QRS duration measurement using high-frequency electrocardiography: applications and limitations of a new technique. Comput Biomed Res. 15:1982;474-484.
-
(1982)
Comput Biomed Res
, vol.15
, pp. 474-484
-
-
Goldberger, A.L.1
Bhargava, V.2
-
17
-
-
0000214396
-
The normal electrocardiogram and vectorcardiogram
-
In: Macfarlane PW, Veitch-Lawrie TD, editors New York/Oxford/Beijing/Frankfurt/Sao Paulo/Sydney/Tokyo/Toronto: Pergamon Press
-
Macfarlane PW, Veitch-Lawrie TD. The normal electrocardiogram and vectorcardiogram. In: Macfarlane PW, Veitch-Lawrie TD, editors. Comprehensive electrocardiology. New York/Oxford/Beijing/Frankfurt/Sao Paulo/Sydney/Tokyo/Toronto: Pergamon Press, 1989:408-57.
-
(1989)
Comprehensive Electrocardiology
, pp. 408-457
-
-
Macfarlane, P.W.1
Veitch-Lawrie, T.D.2
-
18
-
-
0007521372
-
Computer analysis of the electrocardiogram
-
In: Macfarlane PW, Veitch-Lawrie TD, editors New York/Oxford/Beijing/Frankfurt/Sao Paulo/Sydney/Tokyo/Toronto: Pergamon Press
-
Willems JL. Computer analysis of the electrocardiogram. In: Macfarlane PW, Veitch-Lawrie TD, editors. Comprehensive electrocardiology, vol. 2. New York/Oxford/Beijing/Frankfurt/Sao Paulo/Sydney/Tokyo/Toronto: Pergamon Press, 1989:1139-76.
-
(1989)
Comprehensive Electrocardiology
, vol.2
, pp. 1139-1176
-
-
Willems, J.L.1
-
19
-
-
0015902505
-
Clustering algorithm for QRS and ST-T waveform typing
-
Van Bemmel J.H., Hengevelt S.J. Clustering algorithm for QRS and ST-T waveform typing. Comput. Biomed. Res. 6:1973;442-456.
-
(1973)
Comput. Biomed. Res.
, vol.6
, pp. 442-456
-
-
Van Bemmel, J.H.1
Hengevelt, S.J.2
-
20
-
-
0344206883
-
The true boundary recognition of multidimensional detection functions. An optimal comparison
-
In: Willems JL, van Bemmel JH, Ziwietz C, editors Amsterdam: North Holland
-
Rubel P, Ayad B. The true boundary recognition of multidimensional detection functions. An optimal comparison. In: Willems JL, van Bemmel JH, Ziwietz C, editors. Computer ECG analysis: towards standardization. Amsterdam: North Holland, 1986:97-103.
-
(1986)
Computer ECG Analysis: Towards Standardization
, pp. 97-103
-
-
Rubel, P.1
Ayad, B.2
-
23
-
-
0023492181
-
Influence of noise on wave boundary recognition by ECG measurement programs. Recommendations for preprocessing
-
Willems J.L., Zywietz C., Arnaud P., van Bemmel J.H., Degani R., Macfarlane P.W. Influence of noise on wave boundary recognition by ECG measurement programs. Recommendations for preprocessing. Comput Biomed Res. 20:1987;543-562.
-
(1987)
Comput Biomed Res
, vol.20
, pp. 543-562
-
-
Willems, J.L.1
Zywietz, C.2
Arnaud, P.3
Van Bemmel, J.H.4
Degani, R.5
Macfarlane, P.W.6
-
24
-
-
0027628261
-
Digital filters for the detection of late potentials in high-resolution ECG
-
Gramatikov B. Digital filters for the detection of late potentials in high-resolution ECG. Med Biol Eng Comput. 31:1993;415-420.
-
(1993)
Med Biol Eng Comput
, vol.31
, pp. 415-420
-
-
Gramatikov, B.1
-
25
-
-
0028943857
-
Optimal filtering and quality control of the signal averaged ECG. High fidelity 1-minute recordings
-
Lander P., Barbari E.J., Lazzara R. Optimal filtering and quality control of the signal averaged ECG. High fidelity 1-minute recordings. Circulation. 91:1995;1495-1505.
-
(1995)
Circulation
, vol.91
, pp. 1495-1505
-
-
Lander, P.1
Barbari, E.J.2
Lazzara, R.3
-
26
-
-
0029038093
-
Reproducibility of the signal averaged electrocardiogram using individual lead analysis
-
Aganauskiene J., Sornmo L., Ataruis R., Blomstrom-Lundqvist C. Reproducibility of the signal averaged electrocardiogram using individual lead analysis. Eur Heart J. 16:1995;1244-1254.
-
(1995)
Eur Heart J
, vol.16
, pp. 1244-1254
-
-
Aganauskiene, J.1
Sornmo, L.2
Ataruis, R.3
Blomstrom-Lundqvist, C.4
-
27
-
-
0344638408
-
Effetti delle techniche di filtraggio sull'analisi nel dominio del tempo del signal-averaged ecg dopo infarto miocardico acuto: Stidio multicentrico, GISSI-3 sottoprogetto aritmie
-
del Greco M., Nollo G., Disertori M., Sanna G., Maggiono A.P., Santoro E., Tarantino F., Della Mea M.T., Antolini R., Micciolo R. Effetti delle techniche di filtraggio sull'analisi nel dominio del tempo del signal-averaged ecg dopo infarto miocardico acuto: stidio multicentrico, GISSI-3 sottoprogetto aritmie. Giorn Ital Cardiol. 26:1996;73-84.
-
(1996)
Giorn Ital Cardiol
, vol.26
, pp. 73-84
-
-
Del Greco, M.1
Nollo, G.2
Disertori, M.3
Sanna, G.4
Maggiono, A.P.5
Santoro, E.6
Tarantino, F.7
Della Mea, M.T.8
Antolini, R.9
Micciolo, R.10
-
28
-
-
0025318017
-
New algorithm for QT interval analysis in 24-hour Holter ECG: Performance and applications
-
Laguna P., Thakor N.V., Caminal P., Jane R., Yoon H.R., Bayes de Luna A., Marti V., Guindo J. New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applications. Med Biol Eng Comput. 28:1990;67-73.
-
(1990)
Med Biol Eng Comput
, vol.28
, pp. 67-73
-
-
Laguna, P.1
Thakor, N.V.2
Caminal, P.3
Jane, R.4
Yoon, H.R.5
Bayes De Luna, A.6
Marti, V.7
Guindo, J.8
-
29
-
-
0028128685
-
Automatic QRS onset and offset detection for body surface integral mapping of ventricular tachycardia
-
Kemmelings J.G., Linnenbank Mulwijk S.L., Sippens-Groenwegen A., Peper A., Grimbergen C.A. Automatic QRS onset and offset detection for body surface integral mapping of ventricular tachycardia. IEEE Trans Biomed Eng. 41:1994;830-836.
-
(1994)
IEEE Trans Biomed Eng
, vol.41
, pp. 830-836
-
-
Kemmelings, J.G.1
Linnenbank Mulwijk, S.L.2
Sippens-Groenwegen, A.3
Peper, A.4
Grimbergen, C.A.5
-
30
-
-
0031013508
-
Using wavelet transforms for ECG characterization. An on-line digital signal processing system
-
Sahambi J.S., Tandon S.N., Bratt R.K.P. Using wavelet transforms for ECG characterization. An on-line digital signal processing system. IEEE Eng Med Biol. 16:1997;77-83.
-
(1997)
IEEE Eng Med Biol
, vol.16
, pp. 77-83
-
-
Sahambi, J.S.1
Tandon, S.N.2
Bratt, R.K.P.3
-
31
-
-
0028211695
-
Automatic detection of wave boundaries in multilead ECG signals: Validation with the CSE database
-
Laguna P., Jane R., Caminal P. Automatic detection of wave boundaries in multilead ECG signals: validation with the CSE database. Comput Biomed Res. 27:1994;45-60.
-
(1994)
Comput Biomed Res
, vol.27
, pp. 45-60
-
-
Laguna, P.1
Jane, R.2
Caminal, P.3
-
33
-
-
0024041872
-
New approach to the digital elimination of 50 Hz interference from the electrocardiogram
-
Christov I., Dotsinsky I. New approach to the digital elimination of 50 Hz interference from the electrocardiogram. Med Biol Eng Comput. 26:1988;431-434.
-
(1988)
Med Biol Eng Comput
, vol.26
, pp. 431-434
-
-
Christov, I.1
Dotsinsky, I.2
-
34
-
-
0030292888
-
Accuracy of the 50 Hz interference subtraction from the electrocardiogram
-
Dotsinsky I., Daskalov I. Accuracy of the 50 Hz interference subtraction from the electrocardiogram. Med Biol Eng Comput. 34:1996;489-493.
-
(1996)
Med Biol Eng Comput
, vol.34
, pp. 489-493
-
-
Dotsinsky, I.1
Daskalov, I.2
-
35
-
-
0042553279
-
Smoothing and differentiation of data by simplified least squares procedures
-
Savitzky A., Golay M. Smoothing and differentiation of data by simplified least squares procedures. Anal Chem. 36:1964;1627-1639.
-
(1964)
Anal Chem
, vol.36
, pp. 1627-1639
-
-
Savitzky, A.1
Golay, M.2
|