메뉴 건너뛰기




Volumn 46, Issue 3, 1999, Pages 728-736

FLASH correlation: a new method for 3-D ultrasound tissue motion tracking and blood velocity estimation

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; OPTICAL CORRELATION; SPECKLE; STABILITY; THREE DIMENSIONAL; TISSUE; ULTRASONIC VELOCITY; ULTRASONICS;

EID: 0032633832     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.764859     Document Type: Article
Times cited : (22)

References (18)
  • 1
    • 0027559559 scopus 로고    scopus 로고
    • Current time-domain methods for assessing tissue motion by analysis from reflected ultra-sound echoes-A review
    • vol. 40, no. 2, pp. 84-102, 1993.
    • I. A. Hein and W. D. O'Brien. Jr., Current time-domain methods for assessing tissue motion by analysis from reflected ultra-sound echoes-A review, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 40, no. 2, pp. 84-102, 1993.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Hein, I.A.1    O'Brien Jr., W.D.2
  • 4
    • 0038697225 scopus 로고    scopus 로고
    • Real-time two-dimensional vector velocity mapping ultrasound systems using subaperturc pulse chasing
    • vol. 18, p. 60, 1996.
    • P. J. Phillips, S. W. Straka, and O. T. von Ramm, Real-time two-dimensional vector velocity mapping ultrasound systems using subaperturc pulse chasing, Ultrason. Imaging, vol. 18, p. 60, 1996.
    • Ultrason. Imaging
    • Phillips, P.J.1    Straka, S.W.2    Von Ramm, O.T.3
  • 5
    • 0019961998 scopus 로고    scopus 로고
    • A double beam Doppler ultrasound method for quantitative blood flow velocity measurement
    • vol. 8, pp. 421-425, 1982.
    • W. Wang and L. Yao, ''A double beam Doppler ultrasound method for quantitative blood flow velocity measurement, Ultrason. Med. Biol, vol. 8, pp. 421-425, 1982.
    • Ultrason. Med. Biol
    • Wang, W.1    Yao, L.2
  • 6
    • 0026506851 scopus 로고    scopus 로고
    • Vector Doppler: Accurate measurement of blood velocity in two dimensions
    • vol. 18, pp. 19-32, 1992.
    • J. R. Overbeck, K. W. Beach, and E. Strandness, Vector Doppler: Accurate measurement of blood velocity in two dimensions, Ultrason. Med. Dial, vol. 18, pp. 19-32, 1992.
    • Ultrason. Med. Dial
    • Overbeck, J.R.1    Beach, K.W.2    Strandness, E.3
  • 9
    • 0026123398 scopus 로고    scopus 로고
    • A novel method for angle independent ultrasonic imaging of blood flow and tissue motion
    • vol. 38, no. 3, pp. 280-286, 1991.
    • [91 L. N. Bohs and G. E. Trahey, A novel method for angle independent ultrasonic imaging of blood flow and tissue motion, IEEE Trans. Biomed. Eng., vol. 38, no. 3, pp. 280-286, 1991.
    • IEEE Trans. Biomed. Eng.
    • Bohs, L.N.1    Trahey, G.E.2
  • 10
    • 0032072540 scopus 로고    scopus 로고
    • Multi-dimensional velocity estimation with ultrasound using spatial quadrature
    • vol. 45, no. 3, pp. 852-861, 1998.
    • M. E. Anderson, Multi-dimensional velocity estimation with ultrasound using spatial quadrature, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 45, no. 3, pp. 852-861, 1998.
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Anderson, M.E.1
  • 12
    • 33749759094 scopus 로고    scopus 로고
    • 3D Ultrasound tissue motion tracking using correlation search, unpublished.
    • A. A. Morsy and O. T. von Ramm. 3D Ultrasound tissue motion tracking using correlation search, unpublished.
    • Morsy, A.A.1    Von Ramm, O.T.2
  • 13
    • 0029028286 scopus 로고    scopus 로고
    • Speckle structure in three dimensions
    • vol. 98. no. 1, pp. 35-42, 1995.
    • G. R. Bashford and O. T. von Ramm, Speckle structure in three dimensions, J. Acou.it. Soc.. Amer., vol. 98. no. 1, pp. 35-42, 1995.
    • J. Acou.it. Soc.. Amer.
    • Bashford, G.R.1    Von Ramm, O.T.2
  • 16
    • 33749690618 scopus 로고    scopus 로고
    • Ultrasound blood flow monitor of the non-Doppler type, U.S. Patent 5544657, 1996.
    • L. Kurowski. W. Blanz, and W. Delong, Ultrasound blood flow monitor of the non-Doppler type, U.S. Patent 5544657, 1996.
    • Kurowski, L.1    Blanz, W.2    Delong, W.3
  • 18
    • 0025989419 scopus 로고    scopus 로고
    • Potential and limitations of angle-independent flow detection algorithms using radiofrequency and detected echo signals
    • vol. 13, pp. 252-268, 1991.
    • B. S. Ramamurthy and G. E. Trahey, Potential and limitations of angle-independent flow detection algorithms using radiofrequency and detected echo signals, Ultrason. Imaging, vol. 13, pp. 252-268, 1991.
    • Ultrason. Imaging
    • Ramamurthy, B.S.1    Trahey, G.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.