메뉴 건너뛰기




Volumn 98, Issue 1, 1995, Pages 35-42

Speckle structure in three dimensions

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BRIGHTNESS; DIAGNOSTIC IMAGING; IMAGE QUALITY; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING; ULTRASOUND;

EID: 0029028286     PISSN: 00014966     EISSN: NA     Source Type: Journal    
DOI: 10.1121/1.413690     Document Type: Article
Times cited : (12)

References (18)
  • 1
    • 0017905168 scopus 로고
    • Speckle in Ultrasound B-Mode Scans
    • C.B. Burckhardt, “Speckle in Ultrasound B-Mode Scans,” IEEE Trans. Sonics Ultrason. SU-25, 1–6 (1978).
    • (1978) IEEE Trans. Sonics Ultrason. , vol.25 SU , pp. 1-6
    • Burckhardt, C.B.1
  • 2
    • 0018633963 scopus 로고
    • Acoustic Speckle: Theory and Experimental Analysis
    • J.G. Abbott and F.L. Thurstone, “Acoustic Speckle: Theory and Experimental Analysis,” Ultrason. Imag. 1, 303–324 (1979).
    • (1979) Ultrason. Imag. , vol.1 , pp. 303-324
    • Abbott, J.G.1    Thurstone, F.L.2
  • 4
    • 0021206915 scopus 로고
    • Ultrasound speckle size and lesion signal to noise ratio: verification of theory
    • S. W. Smith and R.F. Wagner, “Ultrasound speckle size and lesion signal to noise ratio: verification of theory,” Ultrason. Imag. 6, 174–180 (1984).
    • (1984) Ultrason. Imag. , vol.6 , pp. 174-180
    • Smith, S.W.1    Wagner, R.F.2
  • 6
    • 0022364646 scopus 로고
    • Texture of B-mode echograms: 3-D simulations and experiments of the effects of diffraction and scatterer density
    • B.J. Oosterveld, J.M. Thijssen, and W.A. Verhoef, “Texture of B-mode echograms: 3-D simulations and experiments of the effects of diffraction and scatterer density,” Ultrason. Imag. 7, 142–160 (1985).
    • (1985) Ultrason. Imag. , vol.7 , pp. 142-160
    • Oosterveld, B.J.1    Thijssen, J.M.2    Verhoef, W.A.3
  • 7
    • 0042772778 scopus 로고
    • Pulse reflection imaging and acoustic speckle
    • Ph.D. dissertation, Stanford University, Stanford, CA
    • S.M. Gehlbach, “Pulse reflection imaging and acoustic speckle,” Ph.D. dissertation, Stanford University, Stanford, CA (1983).
    • (1983)
    • Gehlbach, S.M.1
  • 8
    • 0022717660 scopus 로고
    • Speckle pattern correlation with lateral aperture translation: experimental results and implications for spatial compounding
    • G.E. Trahey, S.W. Smith, and O.T. von Ramm, “Speckle pattern correlation with lateral aperture translation: experimental results and implications for spatial compounding,” IEEE Trans. Ultrason. Ferroelec. Freq. Control UFFC-33, 257–264 (1986).
    • (1986) IEEE Trans. Ultrason. Ferroelec. Freq. Control , vol.33 UFFC , pp. 257-264
    • Trahey, G.E.1    Smith, S.W.2    von Ramm, O.T.3
  • 9
    • 0022734867 scopus 로고
    • Analysis of ultrasound image texture via generalized Rician statistics
    • M.F. Insana, R.F. Wagner, B.S. Garra, D.G. Brown, and T.H. Shawker, “Analysis of ultrasound image texture via generalized Rician statistics,” Opt. Eng. 25(6), 743–748 (1986).
    • (1986) Opt. Eng. , vol.25 , Issue.6 , pp. 743-748
    • Insana, M.F.1    Wagner, R.F.2    Garra, B.S.3    Brown, D.G.4    Shawker, T.H.5
  • 10
    • 0019830580 scopus 로고
    • Textural variations in B-mode ultrasonography: A stochastic model
    • S.W. Flax, G.H. Glover, and N.J. Pelc, “Textural variations in B-mode ultrasonography: A stochastic model,” Ultrason. Imag. 3, 235–257 (1981).
    • (1981) Ultrason. Imag. , vol.3 , pp. 235-257
    • Flax, S.W.1    Glover, G.H.2    Pelc, N.J.3
  • 12
    • 0025515954 scopus 로고
    • Real time volumetric ultrasound imaging system
    • O.T. von Ramm and S.W. Smith, “Real time volumetric ultrasound imaging system,” J. Digital Imag. 3, 261–266 (1990).
    • (1990) J. Digital Imag. , vol.3 , pp. 261-266
    • von Ramm, O.T.1    Smith, S.W.2
  • 13
    • 0023526006 scopus 로고
    • Angle Independent Ultrasonic Detection of Blood Flow
    • G.E. Trahey, J.W. Allison, and O.T. von Ramm, “Angle Independent Ultrasonic Detection of Blood Flow,” IEEE Trans. Biomed. Eng. BME-34, 965–967 (1987).
    • (1987) IEEE Trans. Biomed. Eng. , vol.34 BME , pp. 965-967
    • Trahey, G.E.1    Allison, J.W.2    von Ramm, O.T.3
  • 14
    • 0019918146 scopus 로고
    • Ultrasonically tissue mimicking liver including the frequency dependence of backscatter
    • E.L. Madsen, J.A. Zagzebski, M.F. Insana, T.M. Burke, and G.R. Frank, “Ultrasonically tissue mimicking liver including the frequency dependence of backscatter,” Med. Phys. 9, 703–710 (1982).
    • (1982) Med. Phys. , vol.9 , pp. 703-710
    • Madsen, E.L.1    Zagzebski, J.A.2    Insana, M.F.3    Burke, T.M.4    Frank, G.R.5
  • 16
    • 0022664580 scopus 로고
    • Application of stochastic analysis to ultrasonic echoes-Estimation of attenuation and tissue heterogeneity from peaks of echo envelope
    • P. He and J.F. Greenleaf, “Application of stochastic analysis to ultrasonic echoes-Estimation of attenuation and tissue heterogeneity from peaks of echo envelope,” J. Acoust. Soc. Am. 79, 526–534 (1986).
    • (1986) J. Acoust. Soc. Am. , vol.79 , pp. 526-534
    • He, P.1    Greenleaf, J.F.2
  • 17
    • 84939730902 scopus 로고
    • Mathematical analysis of random noise
    • 24, 46–158 (1945).
    • S.O. Rice, “Mathematical analysis of random noise,” Bell Syst. Tech. J. 23, 282-332 (1944); 24, 46–158 (1945).
    • (1944) Bell Syst. Tech. J. , vol.23 , pp. 282-332
    • Rice, S.O.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.